HHHuanxing Han

Huanxing Han

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Huanxing Han has a total of 17 co-authors. Here are the top co-authors by number of shared publications:

  • Chang Liu

    Center for Translational Medicine, Changzheng Hospital, Second Military Medical University, Shanghai 200433, China

    3 shared publications
  • Jia Chen

    Translational Medicine Center, Changzheng Hospital, The Second Military Medical University, 800 Xiangyin Road, Shanghai 200433, P.R. China

    3 shared publications
  • Hui-Qi Lu

    2 shared publications
  • Huiqi Lu

    Center for Translational Medicine, Changzheng Hospital, Second Military Medical University, Shanghai, People's Republic of China

    2 shared publications
  • Li-Shuang Zhu

    2 shared publications
  • Pengfei Zhang

    Center for Translational Medicine, Changzheng Hospital, Second Military Medical University, Shanghai 200433, China

    2 shared publications

Latest Publications

  • Improving detection sensitivity by oriented bioconjugation of antibodies to quantum dots with a flexible spacer arm for immunoassay

    by Bingbo Zhang, Jiani Yu, Chang Liu, Jun Wang, Huanxing Han, Pengfei Zhang, Donglu Shi

    Antibodies with high targeting capability after being labelled by quantum dots (QDs) have been of great importance for in vitro diagnostic, cellular imaging and in vivo theranostic applications. However, such work concentrating on the conjugation of QDs and antibodies is still insufficient. It is encouraged to develop reliable bioconjugation strategies to improve detection sensitivity of QD–antibody bioconjugates. In this study, two bioconjugation approaches were used for antibody and QDs covalent coupling. Their detection sensitivity was parallelly determined and compared. It was experimentally found that succinimidyl valerate-PEG-maleimide (SMPEG) as the cross linker for oriented bioconjugation of antibodies to QDs with a flexible spacer arm can significantly improve the detection sensitivity of the resulting QD–antibody bioconjugates, compared with those prepared with traditional carbodiimide chemistry using EDC·HCl as the cross linker. Gel electrophoresis suggests antibodies can be successfully conjugated with QDs by both the EDC method and the SMPEG method, but immunofiltration assay shows QD–antibody bioconjugates obtained by the SMPEG strategy have lower detection limits and better linear scope patterns for in vitro molecular diagnosis. In vitro cancer cell imaging further shows that QD–antibody bioconjugates prepared by the SMPEG strategy have superior cell targeting capability without observable nonspecific binding, while the EDC-mediated QD–antibody bioconjugates have low signal to noise ratios with obvious nonspecific cellular binding. Moreover, the number of antibodies conjugated on the surface of QDs was determined by the chemiluminescent dot blot assay, showing 2.13 ± 0.5 and 0.76 ± 0.2 of antibodies per QD by EDC-mediated and SMPEG-mediated coupling, respectively. It further verifies that the SMPEG-mediated coupling strategy can significantly maintain the biological activity of the linked antibodies, even though it has low labelling efficiency. It could be therefore claimed that oriented bioconjugation via the SMPEG coupling strategy is favored by immunoassays, with improved detection sensitivity.


  • Open Access

    Rapid and quantitative detection of C-reactive protein based on quantum dots and immunofiltration assay

    by Pengfei Zhang, Yan Bao, Mohamed Shehata Draz, Huiqi Lu, Chang Liu, Huanxing Han

    Convenient and rapid immunofiltration assays (IFAs) enable on-site “yes” or “no” determination of disease markers. However, traditional IFAs are commonly qualitative or semi-quantitative and are very limited for the efficient testing of samples in field diagnostics. Here, we overcome these limitations by developing a quantum dots (QDs)-based fluorescent IFA for the quantitative detection of C-reactive proteins (CRP). CRP, the well-known diagnostic marker for acute viral and bacterial infections, was used as a model analyte to demonstrate performance and sensitivity of our developed QDs-based IFA. QDs capped with both polyethylene glycol (PEG) and glutathione were used as fluorescent labels for our IFAs. The presence of the surface PEG layer, which reduced the non-specific protein interactions, in conjunction with the inherent optical properties of QDs, resulted in lower background signal, increased sensitivity, and ability to detect CRP down to 0.79 mg/L with only 5 µL serum sample. In addition, the developed assay is simple, fast and can quantitatively detect CRP with a detection limit up to 200 mg/L. Clinical test results of our QD-based IFA are well correlated with the traditional latex enhance immune-agglutination aggregation. The proposed QD-based fluorescent IFA is very promising, and potentially will be adopted for multiplexed immunoassay and in field point-of-care test.


  • Open Access

    Simple and Sensitive Detection of HBsAg by Using a Quantum Dots Nanobeads Based Dot-Blot Immunoassay

    by Pengfei Zhang, Huiqi Lu, Jia Chen, Huanxing Han, Wei Ma

    Simple and sensitive detection of infectious disease at an affordable cost is urgently needed in developing nations. In this regard, the dot blot immunoassay has been used as a common protein detection method for detection of disease markers. However, the traditional signal reporting systems, such as those using enzymes or gold nanoparticles lack sensitivity and thus restrict the application of these methods for disease detection. In this study, we report a simple and sensitive detection method for the detection of infectious disease markers that couples the dot-blot immunoassay with quantum dots nanobeads (QDNBs) as a reporter. First, the QDNBs were prepared by an oil-in-water emulsion-evaporation technique. Because of the encapsulation of several QDs in one particle, the fluorescent signal of reporter can be amplified with QDNBs in a one-step test and be read using a UV lamp obviating the need for complicated instruments. Detection of disease-associated markers in complex mixture is possible, which demonstrates the potential of developing QDNBs into a sensitive diagnostic kit.