Using electromechanical signals recorded from the body for respiratory phase detection and respiratory time estimation: A comparative study
Authors:
- 1 September 2015
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 65-68
Abstract
Electrocardiogram derived respiratory (EDR) is a non-invasive technique to estimate respiratory signal. As an alternative, recent studies suggest using Seismocardiogram to estimate respiratory signal, so called accelerometer derived respiration (ADR). In this study we compared the performance of ADR and EDR in precise detection of respiration phases (inhale and exhale timing). We also compared time lag between breath cycles extracted by use of ADR and EDR, and ground truth (respiratory signal recorded using chest band strain gauge). For this comparative analysis, Seismocardiogram, Single lead electrocardiogram (Lead II), and respiratory signal (using a chest band strain gauge) were recorded from 19 healthy subjects. Principal component analysis (PCA) and envelope detection methods are used to compute EDR and ADR. Initial results show that ADR in z-direction (back to front) seems promising approach in addition to the EDR with accuracy of above 85% in identifying respiration phases (inhale and exhale). 87% of breath cycles extracted from ADR had acceptable time lag compared to ground truth (respiratory signal recorded using a chest band strain gauge). ADR was able to correctly classify heartbeats to inhale and exhale classes with classification accuracy of around 76%.Keywords
This publication has 8 references indexed in Scilit:
- Assessment of respiratory flow and efforts using upper-body accelerationMedical & Biological Engineering & Computing, 2014
- Accelerometer-Based Method for Extracting Respiratory and Cardiac Gating Information for Dual Gating during Nuclear Medicine ImagingInternational Journal of Biomedical Imaging, 2014
- A preliminary study investigating the quantification of beat-to-beat in seismocardiogram signals2013
- An Accelerometer-Based Device for Sleep Apnea ScreeningIEEE Transactions on Information Technology in Biomedicine, 2009
- Respiratory rate derived from principal component analysis of single lead electrocardiogram2008
- Improvement of ballistocardiogram processing by inclusion of respiration informationPhysiological Measurement, 2008
- Estimation of respiratory waveform using an accelerometer2008
- A Robust Method for ECG-Based Estimation of the Respiratory Frequency During Stress TestingIEEE Transactions on Biomedical Engineering, 2006