The organizations/institutes from the scholar's latest article


Mikko Paukkunen has a total of 14 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Using electromechanical signals recorded from the body for respiratory phase detection and respiratory time estimation: A comparative study

    by Nasim Alamdari, Kouhyar Tavakolian, Vahid Zakeri, Reza Fazel-Rezai, Mikko Paukkunen, Raimo Sepponen, Alireza Akhbardeh

    Electrocardiogram derived respiratory (EDR) is a non-invasive technique to estimate respiratory signal. As an alternative, recent studies suggest using Seismocardiogram to estimate respiratory signal, so called accelerometer derived respiration (ADR). In this study we compared the performance of ADR and EDR in precise detection of respiration phases (inhale and exhale timing). We also compared time lag between breath cycles extracted by use of ADR and EDR, and ground truth (respiratory signal recorded using chest band strain gauge). For this comparative analysis, Seismocardiogram, Single lead electrocardiogram (Lead II), and respiratory signal (using a chest band strain gauge) were recorded from 19 healthy subjects. Principal component analysis (PCA) and envelope detection methods are used to compute EDR and ADR. Initial results show that ADR in z-direction (back to front) seems promising approach in addition to the EDR with accuracy of above 85% in identifying respiration phases (inhale and exhale). 87% of breath cycles extracted from ADR had acceptable time lag compared to ground truth (respiratory signal recorded using a chest band strain gauge). ADR was able to correctly classify heartbeats to inhale and exhale classes with classification accuracy of around 76%.


  • Open Access

    Beat-by-Beat Quantification of Cardiac Cycle Events Detected From Three-Dimensional Precordial Acceleration Signals

    by Mikko Paukkunen, Petteri Parkkila, Tero Hurnanen, Mikko Pankaala, Tero Koivisto, Tuomo Nieminen, Raimo Kettunen, Raimo Sepponen

    The vibrations produced by the cardiovascular system that are coupled to the precordium can be noninvasively detected using accelerometers. This technique is called seismocardiography. Although clinical applications have been proposed for seismocardiography, the physiology underlying the signal is still not clear. The relationship of seismocardiograms of on the back-to-front axis and cardiac events is fairly well known. However, the 3-D seismocardiograms detectable with modern accelerometers have not been quantified in terms of cardiac cycle events. A major reason for this might be the degree of intersubject variability observed in 3-D seismocardiograms. We present a method to quantify 3-D seismocardiography in terms of cardiac cycle events. First, cardiac cycle events are identified from the seismocardiograms, and then, assigned a number based on the location in which the corresponding event was found. 396 cardiac cycle events from 9 healthy subjects and 120 cardiac cycle events from patients suffering from atrial flutter were analyzed. Despite the weak intersubject correlation of the waveforms (0.05, 0.27, and 0.15 for the x-, y-, and z-axes, respectively), the present method managed to find latent similarities in the seismocardiograms of healthy subjects. We observed that in healthy subjects the distribution of cardiac cycle event coordinates was centered on specific locations. These locations were different in patients with atrial flutter. The results suggest that spatial distribution of seismocardiographic cardiac cycle events might be used to discriminate healthy individuals and those with a failing heart.


  • Precordial Vibrations

    by Mikko Paukkunen, Matti Linnavuo

    In the era of medicine, the heart and cardiovascular system has become one of the standard observation targets. Palpation and auscultation in the precordial area is performed as part of the regular physical examination to detect possible cardiovascular and pulmonary problems. However, due to the large number of people suffering from cardiovascular problems, labor-intensive methods such as auscultation might be inefficient in preventive cardiovascular condition screening. Seismocardiography (SCG) could have the potential to be a part of the solution to this problem. SCG is one of many modalities of cardiac-induced vibration measurements, and it has been shown to be of use in detecting coronary artery disease and assessing myocardial contractility. Lately, due to advances in sensor technologies, the SCG measurement is being developed by introducing three-dimensional measurements. Three-dimensional approach is considered to yield more information about the cardiovascular system than any single uniaxial approach. In conclusion, SCG seems to have the potential to offer a complementary view to cardiovascular function and a cost-effective method for screening of cardiovascular diseases. SCG is explored in this chapter.

  • A System for Detection of Three-Dimensional Precordial Vibrations

    by Mikko Paukkunen, Matti Linnavuo, Helena Haukilehto, Raimo Sepponen

    Accelerometer-based seismocardiography and sternal acceleration ballistocardiography are promising approaches to the noninvasive detection of precordial vibrations. However, in order to be widely accepted as diagnostic or even prognostic tools, clinical validation and standardization of these methods are necessary. In precordial vibration studies, using all three axes instead of one in cardiac vibration analysis is anticipated to enable more accurate cardiac event detection. Simultaneously acquired electrocardiography, photoplethysmography, and respiration information are considered as promising ways to enhance seismocardiogram analysis. In this article, an easy-to-use system that combines three-dimensional seismocardiography, electrocardiography, photoplethysmography, and respiration measurements is described, and its performance is demonstrated. In the test measurements, the system demonstrated its capability to capture accurate cardiovascular data.