Perpendicular catheter orientation during papillary muscle ablation results in larger, deeper lesions
- 15 February 2022
- journal article
- research article
- Published by Wiley in Journal of Cardiovascular Electrophysiology
- Vol. 33 (4) , 690-695
Abstract
Introduction: Ablation of papillary muscles (PMs) for refractory ventricular arrhythmias can often be challenging. The catheter approach and orientation during ablation may affect optimal radiofrequency (RF) delivery. Yet, no previous study investigated the association between catheter orientation and PM lesion size. We evaluated ablation lesion characteristics with various catheter orientations relative to the PM tissue during open irrigated ablation, using a standardized, experimental setting.Methods: Viable bovine PM was positioned on a load cell in a circulating saline bath. RF ablation was performed over PM tissue at 50 W, with the open irrigated catheter positioned either perpendicular or parallel to the PM surface. Applied force was 10 g. Ablation lesions were sectioned and underwent quantitative morphometric analysis.Results: A catheter position oriented directly perpendicular to the PM tissue resulted in the largest ablation lesion volumes and depths compared with ablation with the catheter parallel to PM tissue (75.26 ± 8.40 mm3 vs. 34.04 ± 2.91 mm3, p < .001) and (3.33 ± 0.18 mm vs. 2.24 ± 0.10 mm, p < .001), respectively. There were no significant differences in initial impedance, peak voltage, peak current, or overall decrease in impedance among groups. Parallel catheter orientation resulted in higher peak temperature (41.33 ± 0.28°C vs. 40.28 ± 0.24°C, p = .003), yet, there were no steam pops in either group.Conclusion: For PM ablation, catheter orientation perpendicular to the PM tissue achieves more effective and larger ablation lesions, with greater lesion depth. This may have implications for the chosen ventricular access approach, the type of catheter used, consideration for remote navigation, and steerable sheaths.Keywords
This publication has 22 references indexed in Scilit:
- Computational Modeling of Open-Irrigated Electrodes for Radiofrequency Cardiac Ablation Including Blood Motion-Saline Flow InteractionPLOS ONE, 2016
- Multicenter Outcomes for Catheter Ablation of Idiopathic Premature Ventricular ComplexesJACC: Clinical Electrophysiology, 2015
- Effects of radiofrequency energy delivered through partially insulated metallic catheter tips on myocardial tissue heating and ablation lesion characteristicsHeart Rhythm, 2015
- Predictors of successful catheter ablation of ventricular arrhythmias arising from the papillary musclesHeart Rhythm, 2010
- Electrocardiographic and Electrophysiological Characteristics in Idiopathic Ventricular Arrhythmias Originating From the Papillary Muscles in the Left VentricleCirculation: Arrhythmia and Electrophysiology, 2010
- Effect of Electrode Orientation on Lesion Sizes Produced by Irrigated Radiofrequency Ablation CathetersJournal of Cardiovascular Electrophysiology, 2009
- Idiopathic Focal Ventricular Arrhythmias Originating from the Anterior Papillary Muscle in the Left VentricleJournal of Cardiovascular Electrophysiology, 2009
- Ventricular Tachycardia Originating From the Posterior Papillary Muscle in the Left VentricleCirculation: Arrhythmia and Electrophysiology, 2008
- The Effect of Ablation Electrode Length and Catheter Tip to Endocardial Orientation on Radiofrequency Lesion Size in the Canine Right AtriumPacing and Clinical Electrophysiology, 2002
- Cardiac alternans: mechanisms and pathophysiological significanceCardiovascular Research, 1999