Contact allergy to the Dexcom G6 glucose monitoring system—Role of 2,2′‐methylenebis(6‐tert‐butyl‐4‐methylphenol) monoacrylate in the new adhesive
Open Access
- 19 May 2022
- journal article
- research article
- Published by Wiley in Contact Dermatitis
- Vol. 87 (3) , 258-264
Abstract
Background: Skin reactions to the glucose monitoring systems Dexcom G5 and G6 have been rare. In 2019, the components of the adhesive were exchanged for better skin fixation. Since then, more and more patients experienced severe skin reactions. A few months ago, 2,2′‐methylenebis(6‐tert‐butyl‐4‐methylphenol) monoacrylate (MBPA) was identified as a new component in the adhesive of the G6 model. Furthermore, it was suspected that isobornyl acrylate (IBOA) was also a component of the exchanged adhesive.Objectives: Our objective was to investigate if MBPA plays a major role in the increasing skin problems of patients without a history of IBOA‐sensitization. Furthermore, our aim was to examine whether IBOA is contained in the newer model adhesive and may also contribute to allergic contact dermatitis (ACD).Patients and Methods: Five patients with a newly occurred ACD caused by the glucose monitoring system Dexcom G6 were investigated. Patch testing including MBPA in three different concentrations, as well as IBOA, were performed. Gas chromatography–mass spectrometry of the newer system Dexcom G6 was carried out.Results: All patients were shown to be sensitized to MBPA, while MBPA 0,5% showed the strongest reaction. On the other hand, IBOA was tested negative.Conclusion: In our study group, MBPA was observed to be the triggering allergen of the recently changed adhesive.Keywords
This publication has 16 references indexed in Scilit:
- Evaluation of Isobornyl Acrylate Content in Medical Devices for Diabetes TreatmentDiabetes Technology & Therapeutics, 2019
- The Dexcom glucose monitoring system—An isobornyl acrylate‐free alternative for diabetic patientsContact Dermatitis, 2019
- Allergic contact dermatitis caused by medical devices for diabetes patients: A reviewContact Dermatitis, 2018
- Isobornyl acrylate contained in the insulin patch pump OmniPod as the cause of severe allergic contact dermatitisContact Dermatitis, 2018
- Allergic contact dermatitis caused by isobornyl acrylate in OmniPod, an innovative tubeless insulin pumpContact Dermatitis, 2018
- Further Evidence of Severe Allergic Contact Dermatitis From Isobornyl Acrylate While Using a Continuous Glucose Monitoring SystemJournal of Diabetes Science and Technology, 2018
- Manufacturing Process Changes and Reduced Skin Irritations of an Adhesive Patch Used for Continuous Glucose Monitoring DevicesJournal of Diabetes Science and Technology, 2017
- Allergic contact dermatitis caused by isobornyl acrylate in Freestyle® Libre, a newly introduced glucose sensorContact Dermatitis, 2017
- Adhesives Used for Diabetes Medical DevicesJournal of Diabetes Science and Technology, 2016
- Sensitization to cyanoacrylates caused by prolonged exposure to a glucose sensor set in a diabetic childContact Dermatitis, 2016