Stefanie Kamann
Research Subjects
Stefanie Kamann has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- Eva Oppel
Department of Dermatology and Allergology Ludwig‐Maximilians‐University Munich Germany
5 shared publications Christof Högg
Department of Conservative Dentistry and Periodontology University Hospital, LMU Munich Germany
4 shared publicationsEva Oppel
Klinik für Dermatologie und Allergologie Ludwig‐Maximilians‐Universität München
3 shared publicationsFranz‐Xaver Reichl
Department of Conservative Dentistry and Periodontology, University Hospital, LMU Munich, Germany
3 shared publicationsLutz Heinemann
Science Consulting in Diabetes, Neuss, Germany
3 shared publicationsNicola Wagner
Hautklinik Universitätsklinik Erlangen Friedrich‐Alexander‐Universität Erlangen‐Nürnberg Erlangen
2 shared publications
Latest Publications
- Open Access
- 19 May 2022
- Published by Wiley in Contact Dermatitis
- Vol. 87 (3) , 258-264
Contact allergy to the Dexcom G6 glucose monitoring system—Role of 2,2′‐methylenebis(6‐tert‐butyl‐4‐methylphenol) monoacrylate in the new adhesive
Background: Skin reactions to the glucose monitoring systems Dexcom G5 and G6 have been rare. In 2019, the components of the adhesive were exchanged for better skin fixation. Since then, more and more patients experienced severe skin reactions. A few months ago, 2,2′‐methylenebis(6‐tert‐butyl‐4‐methylphenol) monoacrylate (MBPA) was identified as a new component in the adhesive of the G6 model. Furthermore, it was suspected that isobornyl acrylate (IBOA) was also a component of the exchanged adhesive.Objectives: Our objective was to investigate if MBPA plays a major role in the increasing skin problems of patients without a history of IBOA‐sensitization. Furthermore, our aim was to examine whether IBOA is contained in the newer model adhesive and may also contribute to allergic contact dermatitis (ACD).Patients and Methods: Five patients with a newly occurred ACD caused by the glucose monitoring system Dexcom G6 were investigated. Patch testing including MBPA in three different concentrations, as well as IBOA, were performed. Gas chromatography–mass spectrometry of the newer system Dexcom G6 was carried out.Results: All patients were shown to be sensitized to MBPA, while MBPA 0,5% showed the strongest reaction. On the other hand, IBOA was tested negative.Conclusion: In our study group, MBPA was observed to be the triggering allergen of the recently changed adhesive.
- 19 May 2022
- Published by Wiley in Contact Dermatitis
- Vol. 87 (3) , 258-264
Open AccessContact allergy to the Dexcom G6 glucose monitoring system—Role of 2,2′‐methylenebis(6‐tert‐butyl‐4‐methylphenol) monoacrylate in the new adhesive
Background: Skin reactions to the glucose monitoring systems Dexcom G5 and G6 have been rare. In 2019, the components of the adhesive were exchanged for better skin fixation. Since then, more and more patients experienced severe skin reactions. A few months ago, 2,2′‐methylenebis(6‐tert‐butyl‐4‐methylphenol) monoacrylate (MBPA) was identified as a new component in the adhesive of the G6 model. Furthermore, it was suspected that isobornyl acrylate (IBOA) was also a component of the exchanged adhesive.Objectives: Our objective was to investigate if MBPA plays a major role in the increasing skin problems of patients without a history of IBOA‐sensitization. Furthermore, our aim was to examine whether IBOA is contained in the newer model adhesive and may also contribute to allergic contact dermatitis (ACD).Patients and Methods: Five patients with a newly occurred ACD caused by the glucose monitoring system Dexcom G6 were investigated. Patch testing including MBPA in three different concentrations, as well as IBOA, were performed. Gas chromatography–mass spectrometry of the newer system Dexcom G6 was carried out.Results: All patients were shown to be sensitized to MBPA, while MBPA 0,5% showed the strongest reaction. On the other hand, IBOA was tested negative.Conclusion: In our study group, MBPA was observed to be the triggering allergen of the recently changed adhesive.
- 11 December 2021
- Published by Wiley in JDDG: Journal der Deutschen Dermatologischen Gesellschaft
- Vol. 19 (12) , 1715-1722
Moderne Sensortechnik zur kontinuierlichen Glukosemessung: Anwendungseinschränkungen durch Kontaktallergien
Zusammenfassung: Diabetes‐Erkrankungen haben in den letzten Jahren weltweit stark zugenommen. Genauso rasant entwickeln sich jedoch auch neue Technologien wie die kontinuierliche Glukosemessung mittels subkutaner Sensoren. Auch die stetig optimierte Insulinpumpentherapie trägt zur verbesserten Lebensqualität bei.Diesen modernen Geräten zur Diabetestherapie ist gemein, dass sie über mehrere Tage an einer Stelle auf der Haut fixiert werden. In den letzten Jahren wurde zunehmend über Hautreaktionen, insbesondere ausgeprägte Kontaktallergien, im Haftareal berichtet. Als Hauptallergen wurde Isobornylacrylat identifiziert, das initial in einem Sensorset zur Glukosemessung enthalten war. Die Entwicklung einer Kontaktallergie kann sowohl den notwendigen kompletten Verzicht auf das Messsystem als auch Kreuzreaktionen zu anderen Systemen bedeuten.
- 11 December 2021
- Published by Wiley in JDDG: Journal der Deutschen Dermatologischen Gesellschaft
- Vol. 19 (12) , 1715-1722
Moderne Sensortechnik zur kontinuierlichen Glukosemessung: Anwendungseinschränkungen durch Kontaktallergien
Zusammenfassung: Diabetes‐Erkrankungen haben in den letzten Jahren weltweit stark zugenommen. Genauso rasant entwickeln sich jedoch auch neue Technologien wie die kontinuierliche Glukosemessung mittels subkutaner Sensoren. Auch die stetig optimierte Insulinpumpentherapie trägt zur verbesserten Lebensqualität bei.Diesen modernen Geräten zur Diabetestherapie ist gemein, dass sie über mehrere Tage an einer Stelle auf der Haut fixiert werden. In den letzten Jahren wurde zunehmend über Hautreaktionen, insbesondere ausgeprägte Kontaktallergien, im Haftareal berichtet. Als Hauptallergen wurde Isobornylacrylat identifiziert, das initial in einem Sensorset zur Glukosemessung enthalten war. Die Entwicklung einer Kontaktallergie kann sowohl den notwendigen kompletten Verzicht auf das Messsystem als auch Kreuzreaktionen zu anderen Systemen bedeuten.
- Open Access
- 9 November 2021
- Published by Wiley in JDDG: Journal der Deutschen Dermatologischen Gesellschaft
- Vol. 19 (12) , 1715-1721
Modern diabetes devices for continuous blood sugar measuring: Limitations due to contact allergies
- 9 November 2021
- Published by Wiley in JDDG: Journal der Deutschen Dermatologischen Gesellschaft
- Vol. 19 (12) , 1715-1721
Open AccessModern diabetes devices for continuous blood sugar measuring: Limitations due to contact allergies
- 15 June 2020
- Published by Wiley in Contact Dermatitis
- Vol. 83 (5) , 429-431
Freestyle libre 2: The new isobornyl acrylate free generation
- 15 June 2020
- Published by Wiley in Contact Dermatitis
- Vol. 83 (5) , 429-431
Freestyle libre 2: The new isobornyl acrylate free generation
- 20 September 2019
- Published by SAGE Publications in Journal of Diabetes Science and Technology
- Vol. 14 (3) , 582-585
Usage of Hydrocolloid-Based Plasters in Patients Who Have Developed Allergic Contact Dermatitis to Isobornyl Acrylate While Using Continuous Glucose Monitoring Systems
Continuous glucose monitoring (CGM) systems replace more and more capillary self-monitoring of blood glucose by patients with diabetes. However, at least a subset of patients experience adverse skin reactions such as severe allergic contact dermatitis (ACD) after prolonged usage of CGM systems. A major allergen isobornyl acrylate (IBOA) has been identified recently. After developing an ACD, patients have difficulties in continuing the usage of their CGM system (and also of, eg, certain patch pumps). Most of such patients look for possibilities to continue the usage of, eg, a CGM system that requires intermittent scanning (iscCGM, Freestyle Libre). Eight patients with a known ACD were supplied with different hydrocolloid-based plasters (n = 5 with Hansaplast blister plaster, n = 2 with Cutimed Hydro B from BSN, and n = 1 with Stomahesive baseplate from Convatec). They attached these plasters to their skin underneath their iscCGM system. All patients were able to continue the usage of this iscCGM system when using such plasters. Patients with ACD benefit from the usage of such plasters; however, some limitations have to be acknowledged.
- 20 September 2019
- Published by SAGE Publications in Journal of Diabetes Science and Technology
- Vol. 14 (3) , 582-585
Usage of Hydrocolloid-Based Plasters in Patients Who Have Developed Allergic Contact Dermatitis to Isobornyl Acrylate While Using Continuous Glucose Monitoring Systems
Continuous glucose monitoring (CGM) systems replace more and more capillary self-monitoring of blood glucose by patients with diabetes. However, at least a subset of patients experience adverse skin reactions such as severe allergic contact dermatitis (ACD) after prolonged usage of CGM systems. A major allergen isobornyl acrylate (IBOA) has been identified recently. After developing an ACD, patients have difficulties in continuing the usage of their CGM system (and also of, eg, certain patch pumps). Most of such patients look for possibilities to continue the usage of, eg, a CGM system that requires intermittent scanning (iscCGM, Freestyle Libre). Eight patients with a known ACD were supplied with different hydrocolloid-based plasters (n = 5 with Hansaplast blister plaster, n = 2 with Cutimed Hydro B from BSN, and n = 1 with Stomahesive baseplate from Convatec). They attached these plasters to their skin underneath their iscCGM system. All patients were able to continue the usage of this iscCGM system when using such plasters. Patients with ACD benefit from the usage of such plasters; however, some limitations have to be acknowledged.
- 28 August 2019
- Published by Wiley in Contact Dermatitis
- Vol. 82 (2) , 101-104
The implanted glucose monitoring system Eversense: An alternative for diabetes patients with isobornyl acrylate allergy
Background: Some patients with diabetes develop skin reactions when using systems for continuous glucose monitoring (CGM) or insulin pumps. Regular usage and long wearing periods lead not only to skin irritation, but also to allergic contact dermatitis. It has been shown that allergens such as isobornyl acrylate (IBOA) are present in the plastic housing and also in the adhesives of medical devices used for diabetes treatment.Objectives: To evaluate the IBOA content of all parts of a newly introduced, implanted CGM system (Eversense) to check whether this can be an alternative for IBOA‐sensitized patients.Methods: The IBOA content of the implanted sensor itself (n = 3), the transmitter (n = 3), and two different types of adhesive (white adhesive [n = 4] and clear adhesive [n = 4]) was measured by gas chromatography/mass spectrometry.Results: No IBOA was found in any part of this CGM system.Conclusions: Patients with an IBOA allergy may be able to use this implanted CGM system.
- 28 August 2019
- Published by Wiley in Contact Dermatitis
- Vol. 82 (2) , 101-104
The implanted glucose monitoring system Eversense: An alternative for diabetes patients with isobornyl acrylate allergy
Background: Some patients with diabetes develop skin reactions when using systems for continuous glucose monitoring (CGM) or insulin pumps. Regular usage and long wearing periods lead not only to skin irritation, but also to allergic contact dermatitis. It has been shown that allergens such as isobornyl acrylate (IBOA) are present in the plastic housing and also in the adhesives of medical devices used for diabetes treatment.Objectives: To evaluate the IBOA content of all parts of a newly introduced, implanted CGM system (Eversense) to check whether this can be an alternative for IBOA‐sensitized patients.Methods: The IBOA content of the implanted sensor itself (n = 3), the transmitter (n = 3), and two different types of adhesive (white adhesive [n = 4] and clear adhesive [n = 4]) was measured by gas chromatography/mass spectrometry.Results: No IBOA was found in any part of this CGM system.Conclusions: Patients with an IBOA allergy may be able to use this implanted CGM system.
- 30 May 2019
- Published by Wiley in Contact Dermatitis
- Vol. 81 (5) , 380-381
Hydrocolloid blister plaster decreases allergic contact dermatitis caused by Freestyle Libre and isobornyl acrylate
- 30 May 2019
- Published by Wiley in Contact Dermatitis
- Vol. 81 (5) , 380-381
Hydrocolloid blister plaster decreases allergic contact dermatitis caused by Freestyle Libre and isobornyl acrylate
- 19 February 2019
- Published by Wiley in Contact Dermatitis
- Vol. 81 (1) , 32-36
The Dexcom glucose monitoring system—An isobornyl acrylate‐free alternative for diabetic patients
Background: Glucose monitoring systems, for example, Freestyle Libre (Abott) and Dexcom (Nintamed), are increasingly being used instead of conventional blood sugar measurement. However, many patients have experienced adverse skin reactions such as severe allergic contact dermatitis (ACD). Finally, in August 2017, the culprit allergen in Freestyle Libre, isobornyl acrylate (IBOA), was identified.Objectives: After patients have developed ACD, it is recommended that they no longer use their glucose monitoring systems. Thus, it is important to find an alternative IBOA‐free device.Patients and Methods: Five patients presented with ACD caused by Freestyle Libre. Each was patch tested with allergens from the baseline series and from a plastics and glues series, and additionally with IBOA 0.1% pet. Gas chromatography‐mass spectrometry (GC/MS) of the Freestyle Libre sensor and the Dexcom sensor was performed. The Dexcom sensor remained on the skin of all patients for at least 2 days.Results: All patients were sensitized to IBOA. GC/MS showed the presence of IBOA in the Freestyle Libre sensor, whereas the Dexcom sensor was IBOA‐free. None of the patients had skin reactions to the Dexcom sensor.Conclusions: Patients with Freestyle Libre and IBOA allergy may use the Dexcom sensor as an alternative for glucose monitoring.
- 19 February 2019
- Published by Wiley in Contact Dermatitis
- Vol. 81 (1) , 32-36
The Dexcom glucose monitoring system—An isobornyl acrylate‐free alternative for diabetic patients
Background: Glucose monitoring systems, for example, Freestyle Libre (Abott) and Dexcom (Nintamed), are increasingly being used instead of conventional blood sugar measurement. However, many patients have experienced adverse skin reactions such as severe allergic contact dermatitis (ACD). Finally, in August 2017, the culprit allergen in Freestyle Libre, isobornyl acrylate (IBOA), was identified.Objectives: After patients have developed ACD, it is recommended that they no longer use their glucose monitoring systems. Thus, it is important to find an alternative IBOA‐free device.Patients and Methods: Five patients presented with ACD caused by Freestyle Libre. Each was patch tested with allergens from the baseline series and from a plastics and glues series, and additionally with IBOA 0.1% pet. Gas chromatography‐mass spectrometry (GC/MS) of the Freestyle Libre sensor and the Dexcom sensor was performed. The Dexcom sensor remained on the skin of all patients for at least 2 days.Results: All patients were sensitized to IBOA. GC/MS showed the presence of IBOA in the Freestyle Libre sensor, whereas the Dexcom sensor was IBOA‐free. None of the patients had skin reactions to the Dexcom sensor.Conclusions: Patients with Freestyle Libre and IBOA allergy may use the Dexcom sensor as an alternative for glucose monitoring.
- 15 March 2018
- Published by SAGE Publications in Journal of Diabetes Science and Technology
- Vol. 12 (3) , 630-633
Further Evidence of Severe Allergic Contact Dermatitis From Isobornyl Acrylate While Using a Continuous Glucose Monitoring System
In the past decade, new diabetes technologies, including continuous glucose monitoring (CGM) systems, support patients with diabetes in their daily struggle with achieving a good glucose control. However, shortly after the first CGM systems appeared on the market, also the first concerns about adverse skin reactions were raised. Most patients claimed to suffer from (sometimes severe) skin irritation, or even allergy, which they related to the (acrylate-based) adhesive part of the device. For a long time the actual substance that caused these skin reactions with, for example, the Flash Glucose Monitoring system (iscCGM; Freestyle® Libre) could not be identified; however, recently Belgian and Swedish dermatologists reported that the majority of their patients that have developed a contact-allergic while using iscCGM react sensitively to a specific acrylate, that is, isobornyl acrylate (IBOA). Subsequently they showed by means of gas chromatography-mass spectrometry that this substance is present in the case of the glucose sensor attached by an adhesive to the skin. We report three additional cases from Germany, including a 10-year-old boy, suffering from severe allergic contact dermatitis to IBOA.
- 15 March 2018
- Published by SAGE Publications in Journal of Diabetes Science and Technology
- Vol. 12 (3) , 630-633
Further Evidence of Severe Allergic Contact Dermatitis From Isobornyl Acrylate While Using a Continuous Glucose Monitoring System
In the past decade, new diabetes technologies, including continuous glucose monitoring (CGM) systems, support patients with diabetes in their daily struggle with achieving a good glucose control. However, shortly after the first CGM systems appeared on the market, also the first concerns about adverse skin reactions were raised. Most patients claimed to suffer from (sometimes severe) skin irritation, or even allergy, which they related to the (acrylate-based) adhesive part of the device. For a long time the actual substance that caused these skin reactions with, for example, the Flash Glucose Monitoring system (iscCGM; Freestyle® Libre) could not be identified; however, recently Belgian and Swedish dermatologists reported that the majority of their patients that have developed a contact-allergic while using iscCGM react sensitively to a specific acrylate, that is, isobornyl acrylate (IBOA). Subsequently they showed by means of gas chromatography-mass spectrometry that this substance is present in the case of the glucose sensor attached by an adhesive to the skin. We report three additional cases from Germany, including a 10-year-old boy, suffering from severe allergic contact dermatitis to IBOA.
- Retracted
- 1 January 2007
- Published by Springer Nature
- p. 737
Retracted Chapter: Familiärer Pemphigus vulgaris
- 1 January 2007
- Published by Springer Nature
- p. 737
RetractedRetracted Chapter: Familiärer Pemphigus vulgaris