Variability in estimating shunt from single pulse oximetry measurements
- 9 April 2015
- journal article
- Published by IOP Publishing in Physiological Measurement
- Vol. 36 (5) , 967-981
Abstract
Virtual shunt describes the overall loss of O 2 content between the alveolar gas and arterial blood. Clinicians indirectly estimate the magnitude of the virtual shunt by monitoring peripheral blood oxygen saturation (SpO 2 ) using non-invasive pulse oximetry. An inherent limitation of this method is the variable precision of pulse oximeters and the non-linear relationship between virtual shunt and SpO 2 which is rarely depicted. We propose a model using a combination of basic physiological equations to analyze the estimation of virtual shunt from inspired oxygen (FiO 2 ) and SpO 2 . The model emphasizes the effect of the non-linearity of the Hb–O 2 dissociation curve. Furthermore, it accounts for the variability in SpO 2 measurements due to the precision of pulse oximeters. The model was validated with experiments conducted on healthy subjects in a normobaric hypoxia chamber comparing the simultaneous readings from two different commercial pulse oximeters at FiO 2 = 21% and 17%. SpO 2 probability distributions calculated from the model were estimated. Although a variable bias (1.2–2.1%) in SpO 2 between the pulse oximeter brands was observed, the tested pulse oximeters were both within tolerance specified by the manufacturers and matched the probability distributions from the model. The theoretical and experimental findings show that the estimation of virtual shunt is challenging with a single SpO 2 measurement using pulse oximeters with tolerances of 2%. Clinical decisions must be based on an appreciation of these limitations.Keywords
This publication has 21 references indexed in Scilit:
- A simple gas exchange model predicting arterial oxygen content for various FiO2 levels2018 40th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC), 2013
- Design challenges for camera oximetry on a mobile phone2012
- HUMAN-CENTERED PHONE OXIMETER INTERFACE DESIGN FOR THE OPERATING ROOM - Pulse Oximeter Interfaced to a Mobile Device for Anesthesia Monitoring in the Developing World2011
- Minimal model quantification of pulmonary gas exchange in intensive care patientsMedical Engineering & Physics, 2010
- Hemoximetry as the “Gold Standard”? Error Assessment Based on Differences Among Identical Blood Gas Analyzer Devices of Five ManufacturersAnesthesia & Analgesia, 2007
- Non-invasive estimation of shunt and ventilation-perfusion mismatchIntensive Care Medicine, 2003
- Discriminating Between the Effect of Shunt and Reduced VA/Q on Arterial Oxygen Saturation is Particularly Useful in Clinical PracticeJournal of Clinical Monitoring and Computing, 2000
- Pulse oximetryCritical Care, 1999
- The Validity and Practicality of Sun-Reactive Skin Types I Through VIArchives of Dermatology, 1988
- THE USE OF ISO-SHUNT LINES FOR CONTROL OF OXYGEN THERAPYBritish Journal of Anaesthesia, 1973