Abstract
The impact of a laser-induced microgroove (LIM) architecture on mechanical responses of two cemented implant systems was evaluated. One system consisted of two aluminum alloy rods bonded end-to-end by polymethylmethacrylate cement. The second system consisted of a custom-made, aluminum tibial tray (TT) cemented in an artificial canine tibia. Control specimens for each system were polished smooth at the cement interface. For LIM samples in the rod system, microgrooves were engraved (100 µm depth, 200 µm width, 500 µm spacing) on the apposing surface of one of the two rods. For TT system testing, LIM engraving (100 µm spacing) was confined to the underside and keel of the tray. Morphological analysis of processed implant surfaces revealed success in laser microgrooving procedures. For cemented rods tested under static tension, load to failure was greater for LIM samples (279.0 ± 14.9 N vs. 126.5 ± 4.5 N). Neither non-grooved nor grooved TT samples failed under cyclic compression testing (100,000 cycles at 1 Hz). Compared with control specimens, LIM TT constructs exhibited higher load to failure under static compression and higher strain at the bone interface under cyclic compression. Laser-induced microgrooving has the potential to improve the performance of cemented orthopedic implants.Keywords
Funding Information
- National Institutes of Health (5P20GM103447)
- University of Central Oklahoma (Faculty On campus grant)
This publication has 31 references indexed in Scilit:
- The effects of combined micron-/submicron-scale surface roughness and nanoscale features on cell proliferation and differentiationBiomaterials, 2011
- The influence of nanoscale grooved substrates on osteoblast behavior and extracellular matrix depositionBiomaterials, 2010
- Finite element simulation of cement‐bone interface micromechanics: A comparison to experimental resultsJournal of Orthopaedic Research, 2009
- The influence of different tibial stem designs in load sharing and stability at the cement–bone interface in revision TKAThe Knee, 2008
- In Vitro Fatigue Failure of Cemented Acetabular Replacements: A Hip Simulator StudyJournal of Biomechanical Engineering, 2008
- Computational assessment of constraint in total knee replacementJournal of Biomechanics, 2008
- Cemented fixation with PMMA or Bis-GMA resin hydroxyapatite cement: effect of implant surface roughnessBiomaterials, 2004
- Optimizing the biomechanical compatibility of orthopedic screws for bone fracture fixationMedical Engineering & Physics, 2002
- Metal plasma immersion ion implantation and deposition: a reviewSurface and Coatings Technology, 1997
- The mechanics of the knee joint in relation to normal walkingJournal of Biomechanics, 1970