Analysis of low‐concentration gas samples with continuous‐flow isotope ratio mass spectrometry: eliminating sources of contamination to achieve high precision
- 9 November 2009
- journal article
- Published by Wiley in Rapid Communications in Mass Spectrometry
- Vol. 23 (23) , 3868-3874
Abstract
Developments in continuous‐flow isotope ratio mass spectrometry have made possible the rapid analysis of δ 13 C in CO 2 of small‐volume gas samples with precisions of ≤0.1‰. Prior research has validated the integrity of septum‐capped vials for collection and short‐term storage of gas samples. However, there has been little investigation into the sources of contamination during the preparation and analysis of low‐concentration gas samples. In this study we determined (1) sources of contamination on a Gasbench II, (2) developed an analytical procedure to reduce contamination, and (3) identified an efficient, precise method for introducing sample gas into vials. We investigated three vial‐filling procedures: (1) automated flush‐fill (AFF), (2) vacuum back‐fill (VBF), and (3) hand‐fill (HF). Treatments were evaluated based on the time required for preparation, observed contamination, and multi‐vial precision. The worst‐case observed contamination was 4.5% of sample volume. Our empirical estimate showed that this level of contamination results in an error of 1.7‰ for samples with near‐ambient CO 2 concentrations and isotopic values that followed a high‐concentration carbonate reference with an isotope ratio of −47‰ (IAEA‐CO‐9). This carry‐over contamination on the Gasbench can be reduced by placing a helium‐filled vial between the standard and the succeeding sample or by ignoring the first two of five sample peaks generated by each analysis. High‐precision (SD ≤0.1‰) results with no detectable room‐air contamination were observed for AFF and VBF treatments. In contrast, the precision of HF treatments was lower (SD ≥0.2‰). VBF was optimal for the preparation of gas samples, as it yielded faster throughput at similar precision to AFF. Copyright © 2009 John Wiley & Sons, Ltd.Keywords
This publication has 17 references indexed in Scilit:
- Collection and storage of CO 2 for 13 C analysis: an application to separate soil CO 2 efflux into root‐ and soil‐derived componentsRapid Communications in Mass Spectrometry, 2006
- Flushing time and storage effects on the accuracy and precision of carbon and oxygen isotope ratios of sample using the Gasbench II techniqueRapid Communications in Mass Spectrometry, 2006
- New Guidelines for δ13C MeasurementsAnalytical Chemistry, 2006
- Partitioning the net CO2 flux of a deciduous forest into respiration and assimilation using stable carbon isotopesGlobal Biogeochemical Cycles, 2005
- Kel‐F™ discs improve storage time of canopy air samples in 10‐mL vials for CO 2 ‐δ 13 C analysisRapid Communications in Mass Spectrometry, 2004
- Changes in Composition of Nitrogen‐15‐Labeled Gases during Storage in Septum‐Capped VialsSoil Science Society of America Journal, 2003
- Using septum‐capped vials with continuous‐flow isotope ratio mass spectrometric analysis of atmospheric CO 2 for Keeling plot applicationsRapid Communications in Mass Spectrometry, 2001
- Sample vial influences on the accuracy and precision of carbon and oxygen isotope ratio analysis in continuous flow mass spectrometric applicationsRapid Communications in Mass Spectrometry, 2000
- High-precision continuous-flow isotope ratio mass spectrometryMass Spectrometry Reviews, 1997
- Rapid, automated analysis of13C and18O of CO2 in gas samples by continuous-flow, isotope ratio mass spectrometryJournal of Mass Spectrometry, 1991