Actual tissue temperature during ablation index‐guided high‐power short‐duration ablation versus standard ablation: Implications in terms of the efficacy and safety of atrial fibrillation ablation
- 28 October 2021
- journal article
- research article
- Published by Wiley in Journal of Cardiovascular Electrophysiology
- Vol. 33 (1) , 55-63
Abstract
Background: Actual in vivo tissue temperatures and the safety profile during high‐power short‐duration (HPSD) ablation of atrial fibrillation have not been clarified.Methods: We conducted an animal study in which, after a right thoracotomy, we implanted 6–8 thermocouples epicardially in the superior vena cava, right pulmonary vein, and esophagus close to the inferior vena cava. We recorded tissue temperatures during a 50 W‐HPSD ablation and 30 W‐standard ablation targeting an ablation index (AI) of 400 (5–15 g contact force).Results: Maximum tissue temperatures reached with HSPD ablation were significantly higher than that reached with standard ablation (62.7 ± 12.5 vs. 52.7 ± 11.4°C, p = 0.033) and correlated inversely with the distance between the catheter tip and thermocouple, regardless of the power settings (HPSD: r = −0.71; standard: r = −0.64). Achievement of lethal temperatures (≥50°C) was within 7.6 ± 3.6 and 12.1 ± 4.1 s after HPSD and standard ablation, respectively (p = 0.003), and was best predicted at cutoff points of 5.2 and 4.4 mm, respectively. All HPSD ablation lesions were transmural, but 19.2% of the standard ablation lesions were not (p = 0.011). There was no difference between HPSD and standard ablation regarding the esophageal injury rate (30% vs. 33.3%, p > 0.99), with the injury appearing to be related to the short distance from the catheter tip.Conclusions: Actual tissue temperatures reached with AI‐guided HPSD ablation appeared to be higher with a greater distance between the catheter tip and target tissue than those with standard ablation. HPSD ablation for <7 s may help prevent collateral tissue injury when ablating within a close distance.Keywords
Funding Information
- Biosense Webster
This publication has 27 references indexed in Scilit:
- Wall thickness of the pulmonary vein-left atrial junction rather than electrical information as the major determinant of dormant conduction after contact force-guided pulmonary vein isolationJournal of Interventional Cardiac Electrophysiology, 2016
- Relation Between Left Atrial Wall Thickness in Patients with Atrial Fibrillation and Intracardiac Electrogram Characteristics and ATP‐Provoked Dormant Pulmonary Vein ConductionJournal of Cardiovascular Electrophysiology, 2015
- Spatial and Time-Course Thermodynamics During Pulmonary Vein Isolation Using the Second-Generation Cryoballoon in a Canine In Vivo ModelCirculation: Arrhythmia and Electrophysiology, 2015
- Mechanism of Tissue Heating During High Intensity Focused Ultrasound Pulmonary Vein Isolation: Implications for Atrial Fibrillation Ablation Efficacy and Phrenic Nerve ProtectionJournal of Cardiovascular Electrophysiology, 2008
- The architecture of the left lateral atrial wall: a particular anatomic region with implications for ablation of atrial fibrillationEuropean Heart Journal, 2008
- Morphologic Characteristics of the Left Atrial Appendage, Roof, and Septum: Implications for the Ablation of Atrial FibrillationJournal of Cardiovascular Electrophysiology, 2006
- Discrepancies Between Catheter Tip and Tissue Temperature in Cooled-Tip AblationCirculation, 2005
- Analysis of Catheter-Tip (8-mm) and Actual Tissue Temperatures Achieved During Radiofrequency Ablation at the Orifice of the Pulmonary VeinCirculation, 2004
- Basic Aspects of Radiofrequency Catheter AblationJournal of Cardiovascular Electrophysiology, 1994
- Tissue Heating During Radiofrequency Catheter Ablation: A Thermodynamic Model and Observations in Isolated Perfused and Superfused Canine Right Ventricular Free WallPacing and Clinical Electrophysiology, 1989