Abstract
Sudden increases in the DC link voltage, caused by AC grid side voltage drops, can lead to potential damage of the equipment. Therefore, DC Choppers are widely used in offshore wind power links to absorb the excess energy and keep the voltage within safe margins. This paper investigates the existing chopper topologies and summarizes their advantages and disadvantages. On this basis, a novel DC chopper topology with both centralized and distributed resistances is proposed. It is a combination of two mainstream chopper topologies and gives the flexibility to trade-off among the pros and cons of them. In this way, the proposed topology achieves great EMI performance, precise power control and very small system disturbance. In addition, the maximum power dissipation of the distributed resistance is reduced by 75%. The switching frequency and the loss of IGBTs are also decreased. Finally, the claimed attributes of the proposed topology are verified by test and simulation.

This publication has 20 references indexed in Scilit: