BXBing Xia

Bing Xia

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Bing Xia has a total of 11 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • A Novel DC Chopper Topology for VSC-Based Offshore Wind Farm Connection

    by Bin Xu, Chong Gao, Jing Zhang, Jun Yang, Bing Xia, Zhiyuan He

    Sudden increases in the DC link voltage, caused by AC grid side voltage drops, can lead to potential damage of the equipment. Therefore, DC Choppers are widely used in offshore wind power links to absorb the excess energy and keep the voltage within safe margins. This paper investigates the existing chopper topologies and summarizes their advantages and disadvantages. On this basis, a novel DC chopper topology with both centralized and distributed resistances is proposed. It is a combination of two mainstream chopper topologies and gives the flexibility to trade-off among the pros and cons of them. In this way, the proposed topology achieves great EMI performance, precise power control and very small system disturbance. In addition, the maximum power dissipation of the distributed resistance is reduced by 75%. The switching frequency and the loss of IGBTs are also decreased. Finally, the claimed attributes of the proposed topology are verified by test and simulation.


  • Decentralized Control Method for Modular Multilevel Converters

    by Bing Xia, Yaohua Li, Zixin Li, Georgios Konstantinou, Fei Xu, Fanqiang Gao, Ping Wang

    A decentralized control method for power module (PM) capacitor voltage and switching frequency balancing in modular multilevel converter (MMC) is presented in this paper. The proposed method is composed of a central controller, six arm controllers and several group controllers. The group controller is only in charge of the PM capacitor voltage balancing within a corresponding group and the arm controller is in charge of the PM capacitor voltage balancing and PM switching frequency balancing among groups within an arm. The key advantages of the proposed method are the reduction in the number of the PM capacitor voltages that need to be transmitted and sorted in each group controller as well as the reduction of the communication burden between the group and arm controllers. The proposed method is also highly effective under PM faults. The voltage ripple factor and the PM switching frequency of the proposed method are almost identical to the conventional centralized methods. The RT-LAB based real-time control hardware in the loop (HIL) test results of a ±350 kV/1000 MW MMC system verify the correctness and effectiveness of the proposed method.