Comparative Evaluation of the Clinical Efficacy of Four Different Gingival Retraction Systems: An In Vivo Study
Open Access
- 7 April 2022
- journal article
- research article
- Published by Springer Nature in Cureus
- Vol. 14 (4) , e23923
Abstract
Introduction: There are numerous gingival retraction systems available on the market. This study aimed to evaluate the clinical efficacy of four gingival retraction systems, namely, impregnated retraction cord, gingival retraction capsule, retraction paste, and polyvinyl acetate strips. Methods: A total of 20 people were chosen for the study, and 100 specimens were collected. The specimens were classified into five groups based on the materials used for gingival displacement. On the first day, a baseline impression without gingival displacement was made. Afterward, impressions were made with any of the following four gingival retraction systems: impregnated retraction cord (SURE-Cord® Plus; Sure Dent Corporation, Jungwon-gu, South Korea), retraction capsule (3M ESPE astringent retraction paste capsule; 3M Corporation, St. Paul, MN), retraction paste (Traxodent® Hemodent® Paste Retraction System; Premier Dental Co., Plymouth Meeting, PA) and polyvinylacetate strips (Merocel; Merocel Co., Mystic, CT), with a 14-day interval between each system. The amount of gingival displacement was measured using an optical microscope as the distance from the tooth to the gingiva crest in a horizontal plane. Results: All experimental groups had higher gingival displacement than the control group (P < 0.01). Among the experimental groups, polyvinyl acetate strips had the highest gingival displacement value (541.65 μm), followed by impregnated retraction cord (505.37 μm), retraction capsule (333.57 μm), and retraction paste (230.63 μm). Conclusion: Within the limits of this in vivo study, significant differences in horizontal gingival displacement were discovered among the four evaluated systems. The horizontal displacement requirements of 200 μm were exceeded by all four systems. The maximum value for gingival displacement was found in polyvinyl acetate strips (Merocel), followed by impregnated retraction cord (SURE-Cord), and retraction capsule (3M ESPE), and the lowest value was found in retraction paste (Traxodent).Keywords
This publication has 26 references indexed in Scilit:
- A review of contemporary impression materials and techniquesDental Clinics of North America, 2004
- Tissue management with a new gingival retraction material: A preliminary clinical reportThe Journal of Prosthetic Dentistry, 1996
- Altering Gingival Levels: The Restorative Connection Part I: Biologic VariablesJournal of Esthetic and Restorative Dentistry, 1994
- Oral hygiene, periodontal conditions and carious lesions in patients treated with dental bridgesJournal of Clinical Periodontology, 1993
- Evaluation of New Gingival Retraction AgentsJournal of Dental Research, 1991
- Accuracy of addition silicones as a function of techniqueThe Journal of Prosthetic Dentistry, 1986
- Review and survey of medicaments used with gingival retraction cordsThe Journal of Prosthetic Dentistry, 1985
- Clinical effectiveness of mechanical-chemical tissue displacement methodsThe Journal of Prosthetic Dentistry, 1984
- Periodontal conditions in patients treated with dental bridgesJournal of Periodontal Research, 1970
- A rubber-base impression technique for fixed partial denturesThe Journal of Prosthetic Dentistry, 1962