Design of the fast-imaging FIDA diagnostic system in the HL-2A tokamak
- 2 April 2026
- journal article
- Published by IOP Publishing in Plasma Science and Technology
- Vol. 28 (7) , 075101
Abstract
The study of the fast ion distribution and its transport behavior is important for magnetically confined fusion plasma physics. In this paper, a fast-imaging fast ion deuterium alpha emission diagnostic (FI-FIDA) system on the tangential window of the HL-2A device is designed with the aid of the open-source code FIDASIM. Since active FIDA (aFIDA) radiation viewed by tangential sightlines is heavily influenced by spectral lines such as neutral beam emission spectra (BES), direct charge exchange spectra (DCX) and halo spectra (Halo), and the passive FIDA (pFIDA) emission can reach detectable levels comparable to aFIDA radiation in the edge region, this FI-FIDA system design is based on the edge pFIDA radiation. The simulation results show that under the typical HL-2A discharge conditions, the FI-FIDA system can be used to achieve a time resolution of the order of (10–100) μ s and a spectral resolution of 1 nm with channle-channel view chords spacing of 0.5 ○ ±0.1 ○ which is about 2 cm radial separation in the plasma volume at the same time. Taking advantage of the existing BES diagnostic system in HL-2A experiments, the pFIDA signal was observed, verifying the feasibility of the design.Keywords
Funding Information
- SWIP Innovation Initiative Project (202001XWCXRC001)
- Youth Science and Technology Innovation Team of Sichuan Province (2022JDTD0003)
This publication has 55 references indexed in Scilit:
- Near midplane scintillator-based fast ion loss detector on DIII-DReview of Scientific Instruments, 2012
- Measurements of the deuterium ion toroidal rotation in the DIII-D tokamak and comparison to neoclassical theoryPhysics of Plasmas, 2012
- Measurements and modeling of Alfvén eigenmode induced fast ion transport and loss in DIII-D and ASDEX UpgradePhysics of Plasmas, 2011
- Fast-ion Dα measurements of the fast-ion distribution (invited)Review of Scientific Instruments, 2010
- A new fast-ion Dα diagnostic for DIII-DReview of Scientific Instruments, 2008
- The NSTX fast-ion D-alpha diagnosticReview of Scientific Instruments, 2008
- Measurement of the Dα spectrum produced by fast ions in DIII-DReview of Scientific Instruments, 2007
- Fast-ion D-alpha diagnostic for NSTXReview of Scientific Instruments, 2006
- The tokamak Monte Carlo fast ion module NUBEAM in the National Transport Code Collaboration libraryComputer Physics Communications, 2004
- ANTIC: A code for calculation of neutral transport in cylindrical plasmasJournal of Computational Physics, 1981