Initial single surgeon evaluation comparing C-arm fluoroscopy with the Cirq robotic assistance device for instrumentation of the thoracolumbar spine
Open Access
- 19 December 2022
- journal article
- research article
- Published by Springer Nature in BMC Surgery
- Vol. 22 (1) , 1-6
Abstract
Objective: To compare our experience with pedicle screw insertion of the thoracolumbar spine utilizing the Cirq robot assistance device compared with traditional paradigm using fluoroscopy. Methods: We prospectively collected data of patients undergoing pedicle screw instrumentation in the thoracolumbar spine performed by a single surgeon at three different centers. One center took delivery of the Cirq robotic assistance device. Remaining two centers used C-arm fluoroscopy. Demographic information, diagnosis, total OR time, intraoperative complications, unexpected return to the operating room, and hospital readmissions within 90 days was compared between the two cohorts. Results: A total of 166 screws were placed during the study period. Forty percent were placed using the Cirq. Two thirds the patients had traumatic diagnoses with remaining degenerative spine disease. There were no misplaced pedicle screws in either group. While total OR time was longer in the Cirq cohort by 123 min (p = 0.04), actual procedural time was not statistically different (p = 0.11). Nonetheless there were also more hospital readmissions in the Cirq cohort compared with the C arm group (p = 0.04). Conclusions: Thoracolumbar screws inserted using C-arm fluoroscopy utilize less total operating room time with similar accuracy compared with the Cirq robotic assistance device. Further studies are warranted.Keywords
This publication has 10 references indexed in Scilit:
- Postoperative Urinary Retention Following Thoracolumbosacral Spinal Fusion: Prevalence, Risk Factors, and OutcomesCureus, 2021
- Robotic Assistance for Minimally Invasive Cervical Pedicle Instrumentation: Report on Feasibility and SafetyWorld Neurosurgery, 2021
- The Path to Surgical Robotics in NeurosurgeryOperative Neurosurgery, 2021
- Cirq® Robotic Assistance for Minimally Invasive C1-C2 Posterior Instrumentation: Report on Feasibility and SafetyOperative Neurosurgery, 2020
- Risk factors for deep surgical site infection following thoracolumbar spinal surgeryJournal of Neurosurgery: Spine, 2020
- Robot-Assisted Pedicle Screw Placement: Learning Curve ExperienceWorld Neurosurgery, 2019
- First experience with the jump-starting robotic assistance device CirqNeurosurgical Focus, 2018
- Increased Total Anesthetic Time Leads to Higher Rates of Surgical Site Infections in Spinal FusionsSpine, 2017
- Accuracy of robot-guided versus freehand fluoroscopy-assisted pedicle screw insertion in thoracolumbar spinal surgeryNeurosurgical Focus, 2017