Abstract
Metaphyseal augments, such as sleeves, have been introduced to augment the fixation of revision total knee replacement (rTKR) components, and can be used with or without a stem. The effect of sleeve size in combination with stems on the primary stability and load transfer of a rTKR implant in AORI type IIB defects where the defect involves both condyles are poorly understood. The aim of this study was to examine the primary stability of revision tibial tray augmented with a sleeve in an AORI type IIB defect which involves both condyles with loss of cortical and cancellous bone. Finite element models were generated from computed tomography (CT) scans of nine individuals. All the bones used in the study had an AORI type IIB defect. The cohort included eight females (mean weight: 64 kg, height: 1.6 m). Material properties were sampled from CT data and assigned to the FE model. Joint contact forces for level gait, stair descent, and squat were applied. Stemless sleeved implants under various loading conditions were shown to have adequate primary stability in all AORI type IIB defects investigated. Adding a stem only marginally improved the primary stability of the implant but reduced the strain in the metaphysis compared to stemless implants. Once good initial mechanical stability was established with a sleeve, there was no benefit, in terms of primary stability or bone strains, from increasing sleeve size. This study suggests that metaphyseal sleeves, without a stem, can provide the required primary stability required by a rTKR tibial implant, to reconstruct an AORI type IIB defect. © 2019 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop ResKeywords
Funding Information
- DePuy Synthes (IRGP 49)
This publication has 47 references indexed in Scilit:
- The influence of stem length and fixation on initial femoral component stability in revision total knee replacementBone & Joint Research, 2012
- Influence of loading and activity on the primary stability of cementless tibial traysJournal of Orthopaedic Research, 2012
- Analysis of bone–prosthesis interface micromotion for cementless tibial prosthesis fixation and the influence of loading conditionsJournal of Biomechanics, 2010
- Statistical modelling of the whole human femur incorporating geometric and material propertiesMedical Engineering & Physics, 2009
- Porous Tantalum Cones for Large Metaphyseal Tibial Defects in Revision Total Knee ArthroplastyThe Journal of Arthroplasty, 2009
- The management of bone loss in revision total knee replacementThe Journal of Bone and Joint Surgery. British volume, 2008
- Finite element modelling of primary hip stem stability: The effect of interference fitJournal of Biomechanics, 2008
- Tibial Component Fixation in Total Knee Arthroplasty: A Comparison of Pegged and Stemmed DesignsThe Journal of Arthroplasty, 2007
- Impaction Grafting for Bone Defects in Revision Total Knee ArthroplastyClinical Orthopaedics and Related Research, 2006
- Tissue ingrowth into titanium and hydroxyapatite‐coated implants during stable and unstable mechanical conditionsJournal of Orthopaedic Research, 1992