Rami M. A. Al-Dirini
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Rami M. A. Al-Dirini has a total of 47 co-authors. Here are the top co-authors by number of shared publications:
- Mark Taylor
College of Science and Engineering Flinders University Adelaide Australia
14 shared publications - Dermot O'ROurke
ARC ITTC for Joint Biomechanics, Queensland University of Technology, Brisbane, Australia; School of Mechanical, Medical, and Process Engineering, Queensland University of Technology, Brisbane, Australia; Centre for Orthopaedic & Trauma Research, The University of Adelaide, Adelaide, Australia; Medical Device Research Institute, College of Science and Engineering, Flinders University, Adelaide, Australia
5 shared publications - Joshua Twiggs
360 Med Care Sydney Australia
5 shared publications Brad Miles
360 Med Care Sydney Australia
4 shared publicationsDaniel Huff
DePuy Synthes, Johnson and Johnson, Warsaw, USA
4 shared publications- Dominic Thewlis
University of Adelaide
4 shared publications
Latest Publications
- Open Access
- 29 August 2025
- Published by Elsevier in JSES International
- Vol. 9 (6) , 2127-2140
Clinical accuracy of humeral and glenoid component placement in total shoulder arthroplasty using ASTRA patient-specific guides
- 29 August 2025
- Published by Elsevier in JSES International
- Vol. 9 (6) , 2127-2140
Open AccessClinical accuracy of humeral and glenoid component placement in total shoulder arthroplasty using ASTRA patient-specific guides
- Open Access
- 29 June 2025
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
- Vol. 33 (10) , 3675-3685
Coronal plane alignment of the knee classification system does not reliably predict tibiofemoral joint gaps in arthritic knees undergoing total knee arthroplasty
Purpose: Achieving optimal mediolateral balance in extension and flexion is critical for improving outcomes in total knee arthroplasty (TKA). Knee classification tools, like coronal plane alignment of the knee (CPAK), do not directly consider the soft tissue profile of the joint. This study evaluated the variation in tibiofemoral gap measurements across CPAK phenotypes and examined the relationships between preoperative tibiofemoral joint gaps and the arithmetic hip‐knee‐ankle angle (aHKA) and joint line obliquity (JLO), important for TKA planning and execution.Methods: A retrospective analysis of 433 knees from the Joint Dynamics Registry computed tomography (CT) database was performed. Patients received preoperative long‐leg CT scans and extension and flexion distracted radiographs. The CT scans were segmented and landmarked to produce three‐dimensional bone models and derive anatomical measurements, including aHKA and JLO. The models were registered to the two distracted radiographs, and an osteophyte correction algorithm was applied to calculate the medial and lateral joint gaps in extension and flexion. Composite gap measurements (mean and difference) were also determined. Pearson's correlation and multivariate regression assessed the relationships between joint gaps and aHKA and JLO. ANOVA compared joint gaps across CPAK groups.Results: Small but statistically significant differences in joint gap measurements were observed between CPAK groups I and III, and II and III. Weak univariate correlations were observed between aHKA and joint gaps (r ≤ |0.32 |), with fewer statistically significant relationships for JLO (r ≤ |0.15 |). Multivariate regression explained only 10.2% and 1.4% of aHKA and JLO variance, respectively.Conclusion: While useful for describing coronal alignment, CPAK displayed limited predictive capability for preoperative tibiofemoral joint gaps in TKA patients. Direct assessment of joint gaps remains crucial for surgical planning. Future research should focus on integrating joint gap measurements with bony morphology in preoperative planning workflows to improve TKA personalisation.Level of Evidence: Level II.
- 29 June 2025
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
- Vol. 33 (10) , 3675-3685
Open AccessCoronal plane alignment of the knee classification system does not reliably predict tibiofemoral joint gaps in arthritic knees undergoing total knee arthroplasty
Purpose: Achieving optimal mediolateral balance in extension and flexion is critical for improving outcomes in total knee arthroplasty (TKA). Knee classification tools, like coronal plane alignment of the knee (CPAK), do not directly consider the soft tissue profile of the joint. This study evaluated the variation in tibiofemoral gap measurements across CPAK phenotypes and examined the relationships between preoperative tibiofemoral joint gaps and the arithmetic hip‐knee‐ankle angle (aHKA) and joint line obliquity (JLO), important for TKA planning and execution.Methods: A retrospective analysis of 433 knees from the Joint Dynamics Registry computed tomography (CT) database was performed. Patients received preoperative long‐leg CT scans and extension and flexion distracted radiographs. The CT scans were segmented and landmarked to produce three‐dimensional bone models and derive anatomical measurements, including aHKA and JLO. The models were registered to the two distracted radiographs, and an osteophyte correction algorithm was applied to calculate the medial and lateral joint gaps in extension and flexion. Composite gap measurements (mean and difference) were also determined. Pearson's correlation and multivariate regression assessed the relationships between joint gaps and aHKA and JLO. ANOVA compared joint gaps across CPAK groups.Results: Small but statistically significant differences in joint gap measurements were observed between CPAK groups I and III, and II and III. Weak univariate correlations were observed between aHKA and joint gaps (r ≤ |0.32 |), with fewer statistically significant relationships for JLO (r ≤ |0.15 |). Multivariate regression explained only 10.2% and 1.4% of aHKA and JLO variance, respectively.Conclusion: While useful for describing coronal alignment, CPAK displayed limited predictive capability for preoperative tibiofemoral joint gaps in TKA patients. Direct assessment of joint gaps remains crucial for surgical planning. Future research should focus on integrating joint gap measurements with bony morphology in preoperative planning workflows to improve TKA personalisation.Level of Evidence: Level II.
- Open Access
- 3 September 2024
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
- Vol. 33 (2) , 621-633
Functional preoperative assessment of coronal knee laxity better predicts postoperative patient outcomes than intraoperative surgeon‐defined laxity in total knee arthroplasty
Purpose: Intraoperative laxity assessments in total knee arthroplasty (TKA) are subjective, with few studies comparing against standardised preoperative and postoperative assessments. This study compares coronal knee laxity in TKA patients awake and anaesthetised, preprosthesis and postprosthesis implantation, evaluating relationships to patient‐reported outcome measures.Methods: A retrospective analysis of 49 TKA joints included preoperative and postoperative computed tomography scans, stress radiographs and knee injury and osteoarthritis outcome score (KOOS) questionnaire results preoperatively and 12 months postoperatively. The imaging was used to assess functional laxity (FL) in awake patients, whereas computer navigation measured intraoperative surgical laxity (SL) preimplantation and postimplantation, with patients anaesthetised. Varus and valgus stress states and their difference, joint laxity, were measured.Results: SL was greater than FL in both preimplantation [8.1° (interquartile range, IQR 2.0°) and 3.8° (IQR 2.9°), respectively] and postimplantation [3.5° (IQR 2.3°) and 2.5° (IQR 2.7°), respectively]. Preimplantation, SL was more likely than FL to categorise knees as correctable to ±3° of the mechanical axis. Preoperative FL correlated with KOOS Symptoms (r = 0.33, p = .02) and quality of life (QOL) (r = 0.38, p = .01), whereas reducing medial laxity with TKA enhanced postoperative QOL outcomes (p = .02).Conclusions: Functional coronal knee laxity assessment of awake patients is generally lower than intraoperative surgical assessments of anaesthetised patients. Preoperative SL may result in overcorrection of coronal TKA alignment, whereas preoperative FL better predicts postoperative patient outcomes and reflects the patients' native and tolerable knee laxity. Preoperative FL assessment can be used to guide surgical planning.Level of Evidence: Level II.
- 3 September 2024
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
- Vol. 33 (2) , 621-633
Open AccessFunctional preoperative assessment of coronal knee laxity better predicts postoperative patient outcomes than intraoperative surgeon‐defined laxity in total knee arthroplasty
Purpose: Intraoperative laxity assessments in total knee arthroplasty (TKA) are subjective, with few studies comparing against standardised preoperative and postoperative assessments. This study compares coronal knee laxity in TKA patients awake and anaesthetised, preprosthesis and postprosthesis implantation, evaluating relationships to patient‐reported outcome measures.Methods: A retrospective analysis of 49 TKA joints included preoperative and postoperative computed tomography scans, stress radiographs and knee injury and osteoarthritis outcome score (KOOS) questionnaire results preoperatively and 12 months postoperatively. The imaging was used to assess functional laxity (FL) in awake patients, whereas computer navigation measured intraoperative surgical laxity (SL) preimplantation and postimplantation, with patients anaesthetised. Varus and valgus stress states and their difference, joint laxity, were measured.Results: SL was greater than FL in both preimplantation [8.1° (interquartile range, IQR 2.0°) and 3.8° (IQR 2.9°), respectively] and postimplantation [3.5° (IQR 2.3°) and 2.5° (IQR 2.7°), respectively]. Preimplantation, SL was more likely than FL to categorise knees as correctable to ±3° of the mechanical axis. Preoperative FL correlated with KOOS Symptoms (r = 0.33, p = .02) and quality of life (QOL) (r = 0.38, p = .01), whereas reducing medial laxity with TKA enhanced postoperative QOL outcomes (p = .02).Conclusions: Functional coronal knee laxity assessment of awake patients is generally lower than intraoperative surgical assessments of anaesthetised patients. Preoperative SL may result in overcorrection of coronal TKA alignment, whereas preoperative FL better predicts postoperative patient outcomes and reflects the patients' native and tolerable knee laxity. Preoperative FL assessment can be used to guide surgical planning.Level of Evidence: Level II.
- Open Access
- 12 May 2024
- Published by Wiley in Journal of Orthopaedic Research
- Vol. 42 (10) , 2181-2188
Development and validation of a biomechanically fidelic surgical training knee model
Knee arthroplasty technique is constantly evolving and the opportunity for surgeons to practice new techniques is currently highly dependent on the availability of cadaveric specimens requiring certified facilities. The high cost, limited supply, and heterogeneity of cadaveric specimens has increased the demand for synthetic training models, which are currently limited by a lack of biomechanical fidelity. Here, we aimed to design, manufacture, and experimentally validate a synthetic knee surgical training model which reproduces the flexion dependent varus‐valgus (VV) and anterior‐posterior (AP) mechanics of cadaveric knees, while maintaining anatomic accuracy. A probabilistic finite element modeling approach was employed to design physical models to exhibit passive cadaveric VV and AP mechanics. Seven synthetic models were manufactured and tested in a six‐degree‐of‐freedom hexapod robot. Overall, the synthetic models exhibited cadaver‐like VV and AP mechanics across a wide range of flexion angles with little variation between models. In the extended position, two models showed increased valgus rotation (<0.5°), and three models showed increased posterior tibial translation (<1.7 mm) when compared to the 95% confidence interval (CI) of cadaveric measurements. At full flexion, all models showed VV and AP mechanics within the 95% CI of cadaveric measurements. Given the repeatable mechanics exhibited, the knee models developed in this study can be used to reduce the current reliance on cadaveric specimens in surgical training.
- 12 May 2024
- Published by Wiley in Journal of Orthopaedic Research
- Vol. 42 (10) , 2181-2188
Open AccessDevelopment and validation of a biomechanically fidelic surgical training knee model
Knee arthroplasty technique is constantly evolving and the opportunity for surgeons to practice new techniques is currently highly dependent on the availability of cadaveric specimens requiring certified facilities. The high cost, limited supply, and heterogeneity of cadaveric specimens has increased the demand for synthetic training models, which are currently limited by a lack of biomechanical fidelity. Here, we aimed to design, manufacture, and experimentally validate a synthetic knee surgical training model which reproduces the flexion dependent varus‐valgus (VV) and anterior‐posterior (AP) mechanics of cadaveric knees, while maintaining anatomic accuracy. A probabilistic finite element modeling approach was employed to design physical models to exhibit passive cadaveric VV and AP mechanics. Seven synthetic models were manufactured and tested in a six‐degree‐of‐freedom hexapod robot. Overall, the synthetic models exhibited cadaver‐like VV and AP mechanics across a wide range of flexion angles with little variation between models. In the extended position, two models showed increased valgus rotation (<0.5°), and three models showed increased posterior tibial translation (<1.7 mm) when compared to the 95% confidence interval (CI) of cadaveric measurements. At full flexion, all models showed VV and AP mechanics within the 95% CI of cadaveric measurements. Given the repeatable mechanics exhibited, the knee models developed in this study can be used to reduce the current reliance on cadaveric specimens in surgical training.
- 8 April 2024
- Published by Wiley in Journal of Orthopaedic Research
- Vol. 42 (9) , 2035-2042
Determination of preoperative risk factors for iliopsoas tendonitis after total hip arthroplasty: A simulation study
This study aims to identify preoperative risk factors for iliopsoas tendonitis after total hip arthroplasty, a complication typically attributed to acetabular cup position and orientation, using a validated iliopsoas impingement detection simulation. Analyzing CT scans and X‐rays of 448 patients using a validated preoperative planning protocol, patients were simulated for iliopsoas impingement and categorized into at‐risk and not at‐risk groups based on a prior validation study, with a 23% at‐risk incidence. Implementing a propensity score matching algorithm to reduce covariate imbalance, we identified factors that may exacerbate risk of iliopsoas tendonitis. Parameters that were investigated included standing pelvic tilt, functional femoral rotation, and the difference between the planned acetabular cup diameter and native femoral head diameter (ΔC‐NFH). Comparing pelvic tilt, we found a significant difference between the groups (at‐risk: −6.0°, not at‐risk: −0.7°; p << 0.01). A similar trend was noted for ΔC‐NFH (at‐risk: +5.7 mm, not at‐risk: +5.1 mm; p = 0.01). Additional simulations of at‐risk patients indicated increased anteversion of the acetabular cup reduces impingement risk more effectively than medialisation. These findings suggest that spinopelvic parameters may exacerbate iliopsoas irritation risk, underscoring their importance in preoperative planning and patient expectation management. Similar findings of a greater than 6 mm difference between cup size and native femoral head diameter being a significant risk for iliopsoas tendonitis have been observed before, underscoring its potential veracity. These results may provide surgeons with a simple threshold that can be used in determining a cup size to reduce the risk of iliopsoas tendonitis.
- 8 April 2024
- Published by Wiley in Journal of Orthopaedic Research
- Vol. 42 (9) , 2035-2042
Determination of preoperative risk factors for iliopsoas tendonitis after total hip arthroplasty: A simulation study
This study aims to identify preoperative risk factors for iliopsoas tendonitis after total hip arthroplasty, a complication typically attributed to acetabular cup position and orientation, using a validated iliopsoas impingement detection simulation. Analyzing CT scans and X‐rays of 448 patients using a validated preoperative planning protocol, patients were simulated for iliopsoas impingement and categorized into at‐risk and not at‐risk groups based on a prior validation study, with a 23% at‐risk incidence. Implementing a propensity score matching algorithm to reduce covariate imbalance, we identified factors that may exacerbate risk of iliopsoas tendonitis. Parameters that were investigated included standing pelvic tilt, functional femoral rotation, and the difference between the planned acetabular cup diameter and native femoral head diameter (ΔC‐NFH). Comparing pelvic tilt, we found a significant difference between the groups (at‐risk: −6.0°, not at‐risk: −0.7°; p << 0.01). A similar trend was noted for ΔC‐NFH (at‐risk: +5.7 mm, not at‐risk: +5.1 mm; p = 0.01). Additional simulations of at‐risk patients indicated increased anteversion of the acetabular cup reduces impingement risk more effectively than medialisation. These findings suggest that spinopelvic parameters may exacerbate iliopsoas irritation risk, underscoring their importance in preoperative planning and patient expectation management. Similar findings of a greater than 6 mm difference between cup size and native femoral head diameter being a significant risk for iliopsoas tendonitis have been observed before, underscoring its potential veracity. These results may provide surgeons with a simple threshold that can be used in determining a cup size to reduce the risk of iliopsoas tendonitis.
- Open Access
- 17 February 2024
- Published by Wiley in Journal of Orthopaedic Research
- Vol. 42 (7) , 1577-1586
Comparison of iliopsoas tendonitis after hip resurfacing arthroplasty and total hip arthroplasty: A case‐controlled investigation using a validated simulation
Iliopsoas tendonitis, typically caused by impingement with the acetabular cup, occurs in up to 18% of patients after total hip arthroplasty (THA) and up to 30% of patients after hip resurfacing arthroplasty (HRA). We have developed a simulation for detecting iliopsoas impingement and validated it in a previous study of THA patients. However, due to the difference in incidence between HRA and THA, this study had two aims. First, to validate the simulation in a cohort of HRA patients and, second, to comparethe results of the HRA and THA patients to understand any differences in their etiology. We conducted a retrospective search in an experienced surgeon's database for HRA patients with iliopsoas tendonitisand control patients without iliopsoas tendonitis, resulting in two cohorts of 12 patients. Using CT scans, 3D models of the each patient's prosthetic and bony anatomy were generated, landmarked, and simulated. Regarding validation of the simulation for HRA patients, impingement significantly predicted the probability of iliopsoas tendonitis in logistic regression models and the simulation had a sensitivity of 83%, specificity of 100%, and an AUC ROC curve of 0.95. Unexpectedly, the HRA cohort exhibited less impingement than the THA cohort. Our novel simulation has now been demonstrated to detect iliopsoas impingement and differentiate between the symptomatic and asymptomatic cohorts in investigations of THA and HRA patients. This tool has the potential to be used preoperatively, to guide decisions about optimal cup placement, and postoperatively, to assist in the diagnosis of iliopsoas tendonitis.
- 17 February 2024
- Published by Wiley in Journal of Orthopaedic Research
- Vol. 42 (7) , 1577-1586
Open AccessComparison of iliopsoas tendonitis after hip resurfacing arthroplasty and total hip arthroplasty: A case‐controlled investigation using a validated simulation
Iliopsoas tendonitis, typically caused by impingement with the acetabular cup, occurs in up to 18% of patients after total hip arthroplasty (THA) and up to 30% of patients after hip resurfacing arthroplasty (HRA). We have developed a simulation for detecting iliopsoas impingement and validated it in a previous study of THA patients. However, due to the difference in incidence between HRA and THA, this study had two aims. First, to validate the simulation in a cohort of HRA patients and, second, to comparethe results of the HRA and THA patients to understand any differences in their etiology. We conducted a retrospective search in an experienced surgeon's database for HRA patients with iliopsoas tendonitisand control patients without iliopsoas tendonitis, resulting in two cohorts of 12 patients. Using CT scans, 3D models of the each patient's prosthetic and bony anatomy were generated, landmarked, and simulated. Regarding validation of the simulation for HRA patients, impingement significantly predicted the probability of iliopsoas tendonitis in logistic regression models and the simulation had a sensitivity of 83%, specificity of 100%, and an AUC ROC curve of 0.95. Unexpectedly, the HRA cohort exhibited less impingement than the THA cohort. Our novel simulation has now been demonstrated to detect iliopsoas impingement and differentiate between the symptomatic and asymptomatic cohorts in investigations of THA and HRA patients. This tool has the potential to be used preoperatively, to guide decisions about optimal cup placement, and postoperatively, to assist in the diagnosis of iliopsoas tendonitis.
- 19 February 2023
- Published by Wiley in Journal of Orthopaedic Research
- Vol. 41 (8) , 1709-1716
Determining the relationship between tibiofemoral geometry and passive motion with partial least squares regression
Tibiofemoral geometry influences knee passive motion and understanding their relationship can provide insight into knee function and mechanisms of injury. However, the complexity of the geometric constraints has made characterizing the relationship challenging. The aim of this study was to determine the tibiofemoral bone geometries that explain the variation in passive motion using a partial least squares regression (PLSR) model. The PLSR model was developed for 29 healthy cadaver specimens (10 female, 19 male) with femur and tibia geometries retrieved from MRI images and six degree‐of‐freedom tibiofemoral kinematics determined during a flexion cycle with minimal medial pressure. The first 13 partial least squares (PLS) components explained 90% of the variation in the kinematics and accounted for 89% of the variation in geometry. The first three PLS components which shared geometric changes to particular surface congruencies of the tibial and femoral condyles explained the most amount of variation in the kinematics, primarily in anterior–posterior translation. Meanwhile, variations in femoral condyle width and the intercondylar space, tibia plateau size and conformity, and tibia eminences heights in PLS 2 and 4 explained the greatest amount of variation in internal–external rotation. PLS 4 exhibiting variation in overall size of the knee accounted for greatest amount of variation in geometry (50%) and had the greatest influence on the abduction–adduction motion and some on internal–external rotation but, overall, explained only a small proportion of the kinematics (10%). Elucidating the complex relationship between tibiofemoral bone geometry and passive kinematics may help personalize treatments for improved functional outcomes in patients.
- 19 February 2023
- Published by Wiley in Journal of Orthopaedic Research
- Vol. 41 (8) , 1709-1716
Determining the relationship between tibiofemoral geometry and passive motion with partial least squares regression
Tibiofemoral geometry influences knee passive motion and understanding their relationship can provide insight into knee function and mechanisms of injury. However, the complexity of the geometric constraints has made characterizing the relationship challenging. The aim of this study was to determine the tibiofemoral bone geometries that explain the variation in passive motion using a partial least squares regression (PLSR) model. The PLSR model was developed for 29 healthy cadaver specimens (10 female, 19 male) with femur and tibia geometries retrieved from MRI images and six degree‐of‐freedom tibiofemoral kinematics determined during a flexion cycle with minimal medial pressure. The first 13 partial least squares (PLS) components explained 90% of the variation in the kinematics and accounted for 89% of the variation in geometry. The first three PLS components which shared geometric changes to particular surface congruencies of the tibial and femoral condyles explained the most amount of variation in the kinematics, primarily in anterior–posterior translation. Meanwhile, variations in femoral condyle width and the intercondylar space, tibia plateau size and conformity, and tibia eminences heights in PLS 2 and 4 explained the greatest amount of variation in internal–external rotation. PLS 4 exhibiting variation in overall size of the knee accounted for greatest amount of variation in geometry (50%) and had the greatest influence on the abduction–adduction motion and some on internal–external rotation but, overall, explained only a small proportion of the kinematics (10%). Elucidating the complex relationship between tibiofemoral bone geometry and passive kinematics may help personalize treatments for improved functional outcomes in patients.
- Open Access
- 1 January 2023
- Published by British Editorial Society of Bone & Joint Surgery in Bone & Joint Open
- Vol. 4 (1) , 3-12
Iliopsoas tendonitis after total hip arthroplasty
Aims: Iliopsoas impingement occurs in 4% to 30% of patients after undergoing total hip arthroplasty (THA). Despite a relatively high incidence, there are few attempts at modelling impingement between the iliopsoas and acetabular component, and no attempts at modelling this in a representative cohort of subjects. The purpose of this study was to develop a novel computational model for quantifying the impingement between the iliopsoas and acetabular component and validate its utility in a case-controlled investigation. Methods: This was a retrospective cohort study of patients who underwent THA surgery that included 23 symptomatic patients diagnosed with iliopsoas tendonitis, and 23 patients not diagnosed with iliopsoas tendonitis. All patients received postoperative CT imaging, postoperative standing radiography, and had minimum six months’ follow-up. 3D models of each patient’s prosthetic and bony anatomy were generated, landmarked, and simulated in a novel iliopsoas impingement detection model in supine and standing pelvic positions. Logistic regression models were implemented to determine if the probability of pain could be significantly predicted. Receiver operating characteristic curves were generated to determine the model’s sensitivity, specificity, and area under the curve (AUC). Results: Highly significant differences between the symptomatic and asymptomatic cohorts were observed for iliopsoas impingement. Logistic regression models determined that the impingement values significantly predicted the probability of groin pain. The simulation had a sensitivity of 74%, specificity of 100%, and an AUC of 0.86. Conclusion: We developed a computational model that can quantify iliopsoas impingement and verified its accuracy in a case-controlled investigation. This tool has the potential to be used preoperatively, to guide decisions about optimal cup placement, and postoperatively, to assist in the diagnosis of iliopsoas tendonitis. Cite this article: Bone Jt Open 2023;4(1):3–12.
- 1 January 2023
- Published by British Editorial Society of Bone & Joint Surgery in Bone & Joint Open
- Vol. 4 (1) , 3-12
Open AccessIliopsoas tendonitis after total hip arthroplasty
Aims: Iliopsoas impingement occurs in 4% to 30% of patients after undergoing total hip arthroplasty (THA). Despite a relatively high incidence, there are few attempts at modelling impingement between the iliopsoas and acetabular component, and no attempts at modelling this in a representative cohort of subjects. The purpose of this study was to develop a novel computational model for quantifying the impingement between the iliopsoas and acetabular component and validate its utility in a case-controlled investigation. Methods: This was a retrospective cohort study of patients who underwent THA surgery that included 23 symptomatic patients diagnosed with iliopsoas tendonitis, and 23 patients not diagnosed with iliopsoas tendonitis. All patients received postoperative CT imaging, postoperative standing radiography, and had minimum six months’ follow-up. 3D models of each patient’s prosthetic and bony anatomy were generated, landmarked, and simulated in a novel iliopsoas impingement detection model in supine and standing pelvic positions. Logistic regression models were implemented to determine if the probability of pain could be significantly predicted. Receiver operating characteristic curves were generated to determine the model’s sensitivity, specificity, and area under the curve (AUC). Results: Highly significant differences between the symptomatic and asymptomatic cohorts were observed for iliopsoas impingement. Logistic regression models determined that the impingement values significantly predicted the probability of groin pain. The simulation had a sensitivity of 74%, specificity of 100%, and an AUC of 0.86. Conclusion: We developed a computational model that can quantify iliopsoas impingement and verified its accuracy in a case-controlled investigation. This tool has the potential to be used preoperatively, to guide decisions about optimal cup placement, and postoperatively, to assist in the diagnosis of iliopsoas tendonitis. Cite this article: Bone Jt Open 2023;4(1):3–12.
- 21 October 2019
- Published by Springer Nature in Biomechanics and Modeling in Mechanobiology
- Vol. 19 (4) , 1283-1295
Computational efficient method for assessing the influence of surgical variability on primary stability of a contemporary femoral stem in a cohort of subjects
Finite element (FE) modelling can provide detailed information on implant stability; however, its computational cost limits the possibility of completing large numerical analyses into the effect of surgical variability in a cohort of patients. The aim of this study was to develop an efficient surrogate model for a cohort of patients implanted using a common cementless hip stem. FE models of implanted femora were generated from computed tomography images for 20 femora (11 males, 9 females; 50–80 years; 52–116 kg). An automated pipeline generated FE models for 61 different unique scenarios that span the femur-specific range of implant positions. Peak hip contact and muscle forces for stair climbing were scaled to the donors’ body weight and applied to the models. A cohort-specific surrogate for implant micromotion was constructed from Gaussian process models trained using data from FE simulations representing the median and extreme implant positions for each femur. A convergence study confirmed suitability of the sampling method for cohorts with 10+ femora. The final model was trained using data from the 20 femora. Results showed very good agreement between the FE and the surrogate predictions for a total of 1036 alignment scenarios [root mean squared error (RMSE) < 20 µm; \(R_{\text{validation}}^{2}\) = 0.81]. The total time required for the surrogate model to predict the micromotion range associated with surgical variability was approximately one-eighth of the corresponding full FE analysis. This confirms that the developed model is an accurate yet computationally cheaper alternative to full FE analysis when studying the implant robustness in a cohort of 10+ femora.- 21 October 2019
- Published by Springer Nature in Biomechanics and Modeling in Mechanobiology
- Vol. 19 (4) , 1283-1295
Computational efficient method for assessing the influence of surgical variability on primary stability of a contemporary femoral stem in a cohort of subjects
Finite element (FE) modelling can provide detailed information on implant stability; however, its computational cost limits the possibility of completing large numerical analyses into the effect of surgical variability in a cohort of patients. The aim of this study was to develop an efficient surrogate model for a cohort of patients implanted using a common cementless hip stem. FE models of implanted femora were generated from computed tomography images for 20 femora (11 males, 9 females; 50–80 years; 52–116 kg). An automated pipeline generated FE models for 61 different unique scenarios that span the femur-specific range of implant positions. Peak hip contact and muscle forces for stair climbing were scaled to the donors’ body weight and applied to the models. A cohort-specific surrogate for implant micromotion was constructed from Gaussian process models trained using data from FE simulations representing the median and extreme implant positions for each femur. A convergence study confirmed suitability of the sampling method for cohorts with 10+ femora. The final model was trained using data from the 20 femora. Results showed very good agreement between the FE and the surrogate predictions for a total of 1036 alignment scenarios [root mean squared error (RMSE) < 20 µm; \(R_{\text{validation}}^{2}\) = 0.81]. The total time required for the surrogate model to predict the micromotion range associated with surgical variability was approximately one-eighth of the corresponding full FE analysis. This confirms that the developed model is an accurate yet computationally cheaper alternative to full FE analysis when studying the implant robustness in a cohort of 10+ femora.- 24 January 2019
- Published by Wiley in Journal of Orthopaedic Research
- Vol. 37 (5) , 1033-1041
Influence of stems and metaphyseal sleeve on primary stability of cementless revision tibial trays used to reconstruct AORI IIB defects
Metaphyseal augments, such as sleeves, have been introduced to augment the fixation of revision total knee replacement (rTKR) components, and can be used with or without a stem. The effect of sleeve size in combination with stems on the primary stability and load transfer of a rTKR implant in AORI type IIB defects where the defect involves both condyles are poorly understood. The aim of this study was to examine the primary stability of revision tibial tray augmented with a sleeve in an AORI type IIB defect which involves both condyles with loss of cortical and cancellous bone. Finite element models were generated from computed tomography (CT) scans of nine individuals. All the bones used in the study had an AORI type IIB defect. The cohort included eight females (mean weight: 64 kg, height: 1.6 m). Material properties were sampled from CT data and assigned to the FE model. Joint contact forces for level gait, stair descent, and squat were applied. Stemless sleeved implants under various loading conditions were shown to have adequate primary stability in all AORI type IIB defects investigated. Adding a stem only marginally improved the primary stability of the implant but reduced the strain in the metaphysis compared to stemless implants. Once good initial mechanical stability was established with a sleeve, there was no benefit, in terms of primary stability or bone strains, from increasing sleeve size. This study suggests that metaphyseal sleeves, without a stem, can provide the required primary stability required by a rTKR tibial implant, to reconstruct an AORI type IIB defect. © 2019 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res
- 24 January 2019
- Published by Wiley in Journal of Orthopaedic Research
- Vol. 37 (5) , 1033-1041
Influence of stems and metaphyseal sleeve on primary stability of cementless revision tibial trays used to reconstruct AORI IIB defects
Metaphyseal augments, such as sleeves, have been introduced to augment the fixation of revision total knee replacement (rTKR) components, and can be used with or without a stem. The effect of sleeve size in combination with stems on the primary stability and load transfer of a rTKR implant in AORI type IIB defects where the defect involves both condyles are poorly understood. The aim of this study was to examine the primary stability of revision tibial tray augmented with a sleeve in an AORI type IIB defect which involves both condyles with loss of cortical and cancellous bone. Finite element models were generated from computed tomography (CT) scans of nine individuals. All the bones used in the study had an AORI type IIB defect. The cohort included eight females (mean weight: 64 kg, height: 1.6 m). Material properties were sampled from CT data and assigned to the FE model. Joint contact forces for level gait, stair descent, and squat were applied. Stemless sleeved implants under various loading conditions were shown to have adequate primary stability in all AORI type IIB defects investigated. Adding a stem only marginally improved the primary stability of the implant but reduced the strain in the metaphysis compared to stemless implants. Once good initial mechanical stability was established with a sleeve, there was no benefit, in terms of primary stability or bone strains, from increasing sleeve size. This study suggests that metaphyseal sleeves, without a stem, can provide the required primary stability required by a rTKR tibial implant, to reconstruct an AORI type IIB defect. © 2019 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res