Comparison of Free-Living and Laboratory Activity Outcomes from ActiGraph Accelerometers Worn on the Dominant and Non-Dominant Wrists
- 11 August 2020
- journal article
- research article
- Published by Taylor & Francis in Measurement in Physical Education and Exercise Science
- Vol. 24 (4) , 247-257
Abstract
This study evaluated agreement in activity outcomes from ActiGraph accelerometers worn on both wrists in a laboratory and free-living setting. Part 1: Thirty-seven participants (25.5 ± 10.5 years) completed laboratory activities. Part 2: Thirty-nine participants (28.5 ± 9.8 years) wore accelerometers for 7 days. Outcomes included average acceleration and the intensity gradient (IG). Part 1: Average acceleration was equivalent at the group level between devices across all activity intensities. Wide limits of agreement ranging from 20.6% lower to 34.9% higher for the dominant wrist across all activities were observed. Part 2: The IG was equivalent between wrist locations, but average acceleration was approximately 8.5% higher when measured from the dominant wrist. Adjusting average acceleration values by −8.5% from the dominant wrist resulted in average acceleration falling within a strict 5% equivalence zone. Reducing average acceleration values from the dominant wrist by 8.5% results in equivalent outcomes between wrists during free-living.Keywords
This publication has 31 references indexed in Scilit:
- Effects of Frequency Filtering on Intensity and Noise in Accelerometer-Based Physical Activity MeasurementsSensors, 2019
- Comparing physical activity estimates in children from hip-worn Actigraph GT3X+ accelerometers using raw and counts based processing methodsJournal of Sports Sciences, 2018
- A comparison of physical activity from Actigraph GT3X+ accelerometers worn on the dominant and non‐dominant wristClinical Physiology and Functional Imaging, 2018
- A Primer on the Use of Equivalence Testing for Evaluating Measurement AgreementMedicine & Science in Sports & Exercise, 2018
- Large Scale Population Assessment of Physical Activity Using Wrist Worn Accelerometers: The UK Biobank StudyPLOS ONE, 2017
- Physical activity using wrist‐worn accelerometers: comparison of dominant and non‐dominant wristClinical Physiology and Functional Imaging, 2016
- 2011 Compendium of Physical ActivitiesMedicine & Science in Sports & Exercise, 2011
- Validation of the GENEA AccelerometerMedicine & Science in Sports & Exercise, 2011
- Measuring agreement in method comparison studiesStatistical Methods in Medical Research, 1999
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986