Optical coherence tomography measurements with the LENTIS Mplus multifocal intraocular lens
- 4 January 2012
- journal article
- other
- Published by Springer Nature in Graefe's Archive for Clinical and Experimental Ophthalmology
- Vol. 250 (9) , 1395-1398
Abstract
Background To investigate optical coherence tomography (OCT) measurements following implantation of the LENTIS Mplus multifocal IOL, compared with a control group. Methods OCT scans were performed on 50 eyes with the Topcon 3D OCT-1000 in two groups of patients. The first group consisted of patients following implantation of the LENTIS Mplus, and a second group of age-matched control eyes following implantation of a monofocal aspheric IOL. Macular thickness and macular volume values were compared between groups and assessment for any onscreen visible artifacts. Results OCT scans were successfully performed in all 50 eyes with no visible artifacts in either group during scan acquisitions. There were no statistically significant differences (p > 0.05) in any measured or calculated macular thickness or volume values between the two groups. Conclusions OCT measurements with the Topcon 3D OCT-1000 is possible and free from visible artifacts in eyes which have had the LENTIS Mplus multifocal IOL implanted. Macular thickness and volume values were similar to those of an age-matched control group of monofocal aspheric IOLs.Keywords
This publication has 15 references indexed in Scilit:
- The Development of an Instrument to Measure Quality of Vision: The Quality of Vision (QoV) QuestionnaireInvestigative Ophthalmology & Visual Science, 2010
- Correlation between nerve fibre layer thickness measured with spectral domain OCT and visual field in patients with different stages of glaucomaGraefe's Archive for Clinical and Experimental Ophthalmology, 2010
- OCT patterns of macular edema and response to bevacizumab therapy in retinal vein occlusionGraefe's Archive for Clinical and Experimental Ophthalmology, 2010
- Multifocal contact lenses and posterior pole imagingContact Lens and Anterior Eye, 2010
- Cirrus OCT versus Spectralis OCT: differences in segmentation in fibrovascular pigment epithelial detachmentGraefe's Archive for Clinical and Experimental Ophthalmology, 2010
- Relationship between angiographic and optical coherence tomographic (OCT) parameters for quantifying choroidal neovascular lesionsGraefe's Archive for Clinical and Experimental Ophthalmology, 2009
- Wavy horizontal artifacts on optical coherence tomography line-scanning images caused by diffractive multifocal intraocular lensesJournal of Cataract & Refractive Surgery, 2009
- Optical coherence tomography of the retina and optic nerve – a reviewClinical & Experimental Ophthalmology, 2009
- Sixteen S‐squared over D‐squared: A relation for crude sample size estimatesStatistics in Medicine, 1992
- Optical Coherence TomographyScience, 1991