ESEirini Skiadaresi

Eirini Skiadaresi

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Eirini Skiadaresi has a total of 9 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    The Italian Catquest-9SF cataract questionnaire: translation, validation and application

    by Eirini Skiadaresi, Giuseppe Ravalico, Silvio Polizzi, Mats Lundström, Miguel González-Andrades, Colm McAlinden

    To validate the Catquest-9SF questionnaire in Italian, assess the change in visual disability with cataract surgery and determine the correlation between pre-operative Catquest-9SF scores and Lens Opacities Classification System (LOCS) III cataract grading. Prospective, questionnaire validation study. The Catquest-9SF questionnaire was forward and back translated and completed by 209 Italian patients before and three months following cataract surgery. Rasch analysis was used to assess its psychometric properties. The Italian Catquest-9SF demonstrated ordered response categories, unidimensionality (item fit statistics range: 0.73–1.34), adequate person separation (2.04), and no differential item functioning. Mistargeting was evident with a mean difference in item difficulty and person ability of 2.04 logits but improved with inclusion of pre-operative data only. There was a statistically significant (Friedman tests, p < 0.001) median improvement in visual disability of 1.92, 3.57, 1.44 and 2.94 logits in patients undergoing first eye surgery with and without ocular comorbidity, and second eye surgery with and without ocular comorbidity respectively. There was no statistically significant difference in the improvements among the four groups (Kruskal-Wallis H test, X 2 (3) = 5.445, p = 0.142). There was no correlation between Catquest-9SF scores and nuclear opalescence (r s = 0.049, p = 0.478), nuclear colour (r s = 0.008, p = 0.909), cortical (r s = 0.066, p = 0.341), and posterior subcapsular components (r s = 0.048, p = 0.494). The Italian Catquest-9SF demonstrated good psychometric properties and is suitable for use in Italian speaking patients. There were similar improvements in visual disability in patients undergoing first or second eye surgery, with or without ocular comorbidity. There was no correlation between pre-operative Catquest-9SF scores and LOCS III cataract grading.


  • Open Access

    Subjective Quality of Vision Before and After Cataract Surgery

    by Eirini Skiadaresi, Colm McAlinden, Konrad Pesudovs, Silvio Polizzi, Jyoti Khadka, Giuseppe Ravalico

    Cataract surgery is one of the most commonly performed surgical procedures worldwide.1 There have been constant improvements in surgical techniques and equipment, resulting in fewer complications and quicker visual recovery.2 Concurrently, patient expectation and the role of refractive error as both indication and outcome have increased.


  • Optical coherence tomography measurements with the LENTIS Mplus multifocal intraocular lens

    by Eirini Skiadaresi, Colm McAlinden, Giuseppe Ravalico, Jonathan Moore

    Background To investigate optical coherence tomography (OCT) measurements following implantation of the LENTIS Mplus multifocal IOL, compared with a control group. Methods OCT scans were performed on 50 eyes with the Topcon 3D OCT-1000 in two groups of patients. The first group consisted of patients following implantation of the LENTIS Mplus, and a second group of age-matched control eyes following implantation of a monofocal aspheric IOL. Macular thickness and macular volume values were compared between groups and assessment for any onscreen visible artifacts. Results OCT scans were successfully performed in all 50 eyes with no visible artifacts in either group during scan acquisitions. There were no statistically significant differences (p > 0.05) in any measured or calculated macular thickness or volume values between the two groups. Conclusions OCT measurements with the Topcon 3D OCT-1000 is possible and free from visible artifacts in eyes which have had the LENTIS Mplus multifocal IOL implanted. Macular thickness and volume values were similar to those of an age-matched control group of monofocal aspheric IOLs.