Abstract
Objective: To use external anatomical landmarks to determine a new method for the estimation of appropriate insertion length of umbilical catheters, suitable for newborn infants of varying birth weight (BW) and gestational age. Study design: Neonates who had umbilical venous (UVC) or arterial (UAC) catheters placed soon after birth were included in the study. Catheters were placed using formulas derived by Shukla (1986) and/or Wright (2007), and adjusted to appropriate positions confirmed radiologically: UAC tip between T6–T10 vertebral bodies and UVC at the level of the diaphragm±0.5 cms. Final catheter length was compared with the length estimated by Shukla/Wright formulas and to four additional morphometric measurements: umbilicus to nipple (UN), umbilicus to midpoint of inter-mammary distance, umbilicus to xiphoid process and umbilicus to symphysis pubis (USp). Result: Of 216 infants, 32 were excluded; UVC was placed in 170 infants and UAC in 125 infants. Among the morphometric measurements, UN−1 cm ( UN distance minus 1 cm) provided the best estimate of accurate insertion length of UVC, (r=0.984, PPr=0.985, PPP<0.001). Conclusion: Simple and intuitive morphometric measurements UN and USp provide more accurate estimates of appropriate insertion lengths for umbilical catheters in infants with all BWs than commonly used BW-based formulas.
Keywords

This publication has 14 references indexed in Scilit: