Comparison of Efficacy and Complications of Cyclophotocoagulation and Second Glaucoma Drainage Device After Initial Glaucoma Drainage Device Failure
- 1 November 2017
- journal article
- research article
- Published by Wolters Kluwer Health in Journal of Glaucoma
- Vol. 26 (11) , 1010-1018
Abstract
Purpose: Compare intraocular pressure (IOP) control and complication rates of a second glaucoma drainage device (GDD) to diode transscleral cyclophotocoagulation (TSCPC) following failure of an initial GDD. Patients and Methods: Eyes with 1 GDD that required a second GDD or TSCPC for glaucoma control were included. Exclusion criteria were a cyclodestructive procedure before initial GDD, no light perception vision, or follow-up <1 year. Failure was defined as ≥1 of (1) reoperation for lowering IOP; (2) explantation of second GDD; (3) persistent hypotony; (4) use of oral carbonic anhydrase inhibitor for lowering IOP in the study eye; or (5) loss of light perception. Reoperation for lowering IOP included additional GDD implantation or additional cyclodestruction, except if additional cyclodestruction was within 6 months of the initial session. Results: A total of 75 eyes (35 in second GDD; 40 in TSCPC) were included (mean follow-up, 25.5 mo). Both procedures lowered IOP [−11.4 mm Hg (±13.6) for second GDD and −7.8 mm Hg (±11.8) for TSCPC groups] and decreased the number of IOP-lowering medications at the last visit. The second GDD group had significantly greater mean survival time [45.0 mo (±4.2)] than the TSCPC group [26.5 mo (±2.8)] but significantly more postoperative complications (60% of eyes) and non–IOP-related procedures (40% of eyes) than the TSCPC group (20% for postoperative complications and 18% for non–IOP-related procedures). Conclusions: Although both second procedures are efficacious in lowering IOP and number of IOP-lowering medications, TSCPC failed earlier, whereas a second GDD had significantly more complications.Keywords
This publication has 10 references indexed in Scilit:
- A Comparison of Sequential Glaucoma Drainage Device Implantation Versus Cyclophotocoagulation Following Failure of a Primary Drainage DeviceJournal of Glaucoma, 2017
- The Ahmed Versus Baerveldt StudyOphthalmology, 2016
- Use of Various Glaucoma Surgeries and Procedures in Medicare Beneficiaries from 1994 to 2012Ophthalmology, 2015
- Failed glaucoma drainage implant: long-term outcomes of a second glaucoma drainage device versus cyclophotocoagulationBritish Journal of Ophthalmology, 2015
- Five-Year Treatment Outcomes in the Ahmed Baerveldt Comparison StudyOphthalmology, 2015
- Transscleral Diode Laser Cyclophotocoagulation After Baerveldt Glaucoma Implant SurgeryJournal of Glaucoma, 2014
- Treatment Outcomes in the Tube Versus Trabeculectomy (TVT) Study After Five Years of Follow-upAmerican Journal of Ophthalmology, 2012
- Cyclophotocoagulation versus sequential tube shunt as a secondary intervention following primary tube shunt failure in pediatric glaucomaJournal of American Association for Pediatric Ophthalmology and Strabismus, 2009
- Long-term efficacy and visual acuity following transscleral diode laser photocoagulation in cases of refractory and non-refractory glaucomaEye, 2006
- Outcomes of sequential tube shunts in complicated glaucomaOphthalmology, 2000