Motion-Robust Atrial Fibrillation Detection Based on Remote-Photoplethysmography
- 5 May 2022
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Biomedical and Health Informatics
- Vol. 27 (6) , 2705-2716
Abstract
Atrial fibrillation (AF) has been proven highly correlated to stroke; more than 43 million people suffer from AF worldwide. However, most of these patients are unaware of their disease. There is no convenient tool by which to conduct a comprehensive screening to identify asymptomatic AF patients. Hence, we provide a non-contact AF detection approach based on remote photoplethysmography (rPPG). We address motion disturbance, the most challenging issue in rPPG technology, with the NR-Net, ATT-Net, and SQ-Mask modules. NR-Net is designed to eliminate motion noise with a CNN model, and ATT-Net and SQ-Mask utilize channel-wise and temporal attention to reduce the influence of poor signal segments. Moreover, we present an AF dataset collected from hospital wards which contains 452 subjects (mean age, 69.313.0 years; women, 46%) and 7,306 30-second segments to verify the proposed algorithm. To our best knowledge, this dataset has the most participants and covers the full age range of possible AF patients. The proposed method yields accuracy, sensitivity, and specificity of 95.69%, 96.76%, and 94.33%, respectively, when discriminating AF from normal sinus rhythm. More than previous studies, other arrhythmias are also taken into consideration, leading to a further investigation of AF vs. Non-AF and AF vs. Other scenarios. For the three scenarios, the proposed approach outperforms the benchmark algorithms. Additionally, the accuracy of the slight motion data improves to 95.82%, 92.39%, and 89.18% for the three scenarios, respectively, while that of full motion data increases by over 3%.Keywords
Funding Information
- Ministry of Science and Technology, Taiwan (MOST 110-2221-E-A49-125)
This publication has 34 references indexed in Scilit:
- Calibration of Contactless Pulse OximetryAnesthesia & Analgesia, 2017
- Algorithmic Principles of Remote PPGIEEE Transactions on Biomedical Engineering, 2016
- Diagnostic Performance of a Smartphone‐Based Photoplethysmographic Application for Atrial Fibrillation Screening in a Primary Care SettingJournal of the American Heart Association, 2016
- PULSE‐SMART: Pulse‐Based Arrhythmia Discrimination Using a Novel Smartphone ApplicationJournal of Cardiovascular Electrophysiology, 2015
- DistancePPG: Robust non-contact vital signs monitoring using a cameraBiomedical Optics Express, 2015
- Detection of atrial fibrillation using contactless facial video monitoringHeart Rhythm, 2015
- Robust Pulse Rate From Chrominance-Based rPPGIEEE Transactions on Biomedical Engineering, 2013
- LIBSVMACM Transactions on Intelligent Systems and Technology, 2011
- Contribution of Atrial Fibrillation to Incidence and Outcome of Ischemic StrokeStroke, 2005
- Anticoagulants for preventing stroke in patients with nonrheumatic atrial fibrillation and a history of stroke or transient ischaemic attackCochrane Database of Systematic Reviews, 2004