Bing-Jhang Wu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Bing-Jhang Wu has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Bing-Fei Wu
Institute of Electrical and Control Engineering, National Yang Ming Chiao Tung University, Hsinchu, Taiwan
2 shared publications - Chi-Po Hsu
Institute of Electrical and Control Engineering, National Yang Ming Chiao Tung University, Hsinchu, Taiwan
2 shared publications Bing-Fei Wu
Institute of Electrical and Control Engineering, National Yang Ming Chiao Tung University, Hsinchu, Taiwan
1 shared publication- Bing-Ruei Tsai
National Yang Ming Chiao Tung University, Hsinchu, Taiwan
1 shared publication - Meng-Liang Chung
FaceHeart Inc., Hsinchu, Taiwan
1 shared publication - Po-Wei Huang
Institute of Electrical and Control Engineering, National Chiao Tung University, Hsinchu, Taiwan
1 shared publication
Latest Publications
- 24 November 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 72 (00189456) , 1-13
Camera-Based Blood Pressure Estimation via Windkessel Model and Waveform Features
Blood pressure (BP) is generally regarded as the vital sign most strongly correlated with human health. However, for decades, BP measurement has involved a cuff, which causes discomfort and even carries a risk of infection, given the current prevalence of COVID-19. Some studies address these problems using remote photoplethysmography (rPPG), which has shown great success in heart rate detection. Nevertheless, these approaches are not robust, and few have been evaluated with a sufficiently large dataset. We propose an rPPG-based BP estimation algorithm that predicts BP by leveraging the Windkessel model and hand-crafted waveform characteristics. A waveform processing procedure is presented for the rPPG signals to obtain a robust waveform template and thus extract BP-related features. Redundant and unstable features are eliminated via Monte Carlo simulation and according to their relationship with latent parameters in the Windkessel model. For a comprehensive evaluation, the Chiao Tung Blood Pressure (CTBP) dataset was constructed. The experiment was conducted over a four week period of time to evaluate the validity period of the personalization in our system. On all the data, the proposed method outperforms the benchmark algorithms and yields mean absolute errors of 6.48 mmHg and 5.06 mmHg for SBP and DBP, respectively. The performance achieves a “B” grade according to the validation protocol from the British Hypertension Society for both SBP and DBP.
- 24 November 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 72 (00189456) , 1-13
Camera-Based Blood Pressure Estimation via Windkessel Model and Waveform Features
Blood pressure (BP) is generally regarded as the vital sign most strongly correlated with human health. However, for decades, BP measurement has involved a cuff, which causes discomfort and even carries a risk of infection, given the current prevalence of COVID-19. Some studies address these problems using remote photoplethysmography (rPPG), which has shown great success in heart rate detection. Nevertheless, these approaches are not robust, and few have been evaluated with a sufficiently large dataset. We propose an rPPG-based BP estimation algorithm that predicts BP by leveraging the Windkessel model and hand-crafted waveform characteristics. A waveform processing procedure is presented for the rPPG signals to obtain a robust waveform template and thus extract BP-related features. Redundant and unstable features are eliminated via Monte Carlo simulation and according to their relationship with latent parameters in the Windkessel model. For a comprehensive evaluation, the Chiao Tung Blood Pressure (CTBP) dataset was constructed. The experiment was conducted over a four week period of time to evaluate the validity period of the personalization in our system. On all the data, the proposed method outperforms the benchmark algorithms and yields mean absolute errors of 6.48 mmHg and 5.06 mmHg for SBP and DBP, respectively. The performance achieves a “B” grade according to the validation protocol from the British Hypertension Society for both SBP and DBP.
- 5 May 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Biomedical and Health Informatics
- Vol. 27 (6) , 2705-2716
Motion-Robust Atrial Fibrillation Detection Based on Remote-Photoplethysmography
Atrial fibrillation (AF) has been proven highly correlated to stroke; more than 43 million people suffer from AF worldwide. However, most of these patients are unaware of their disease. There is no convenient tool by which to conduct a comprehensive screening to identify asymptomatic AF patients. Hence, we provide a non-contact AF detection approach based on remote photoplethysmography (rPPG). We address motion disturbance, the most challenging issue in rPPG technology, with the NR-Net, ATT-Net, and SQ-Mask modules. NR-Net is designed to eliminate motion noise with a CNN model, and ATT-Net and SQ-Mask utilize channel-wise and temporal attention to reduce the influence of poor signal segments. Moreover, we present an AF dataset collected from hospital wards which contains 452 subjects (mean age, 69.313.0 years; women, 46%) and 7,306 30-second segments to verify the proposed algorithm. To our best knowledge, this dataset has the most participants and covers the full age range of possible AF patients. The proposed method yields accuracy, sensitivity, and specificity of 95.69%, 96.76%, and 94.33%, respectively, when discriminating AF from normal sinus rhythm. More than previous studies, other arrhythmias are also taken into consideration, leading to a further investigation of AF vs. Non-AF and AF vs. Other scenarios. For the three scenarios, the proposed approach outperforms the benchmark algorithms. Additionally, the accuracy of the slight motion data improves to 95.82%, 92.39%, and 89.18% for the three scenarios, respectively, while that of full motion data increases by over 3%.
- 5 May 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Biomedical and Health Informatics
- Vol. 27 (6) , 2705-2716
Motion-Robust Atrial Fibrillation Detection Based on Remote-Photoplethysmography
Atrial fibrillation (AF) has been proven highly correlated to stroke; more than 43 million people suffer from AF worldwide. However, most of these patients are unaware of their disease. There is no convenient tool by which to conduct a comprehensive screening to identify asymptomatic AF patients. Hence, we provide a non-contact AF detection approach based on remote photoplethysmography (rPPG). We address motion disturbance, the most challenging issue in rPPG technology, with the NR-Net, ATT-Net, and SQ-Mask modules. NR-Net is designed to eliminate motion noise with a CNN model, and ATT-Net and SQ-Mask utilize channel-wise and temporal attention to reduce the influence of poor signal segments. Moreover, we present an AF dataset collected from hospital wards which contains 452 subjects (mean age, 69.313.0 years; women, 46%) and 7,306 30-second segments to verify the proposed algorithm. To our best knowledge, this dataset has the most participants and covers the full age range of possible AF patients. The proposed method yields accuracy, sensitivity, and specificity of 95.69%, 96.76%, and 94.33%, respectively, when discriminating AF from normal sinus rhythm. More than previous studies, other arrhythmias are also taken into consideration, leading to a further investigation of AF vs. Non-AF and AF vs. Other scenarios. For the three scenarios, the proposed approach outperforms the benchmark algorithms. Additionally, the accuracy of the slight motion data improves to 95.82%, 92.39%, and 89.18% for the three scenarios, respectively, while that of full motion data increases by over 3%.
- 8 April 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 71 (00189456) , 1-13
A Facial-Image-Based Blood Pressure Measurement System Without Calibration
Blood pressure (BP) is a major vital sign that is highly correlated with human health. However, for decades BP measurement has involved a cuff, which can be uncomfortable and even carry the risk of infection. The remote photoplethysmography (rPPG) technique has gained great success in heart rate monitoring for tackling these problems. Some studies integrate the pulse transit time (PTT) into the system and ask users put their hand beside their face. A calibration procedure is usually needed for such methods. Other methods measure the BP with several rPPG waveform features or the whole rPPG segment. However, these methods remain inconvenient, and few methods evaluate their algorithm with large enough datasets to be effective. Hence, we propose a calibration-free and facial-image-based blood pressure measurement system which takes a deep neural network as the backbone. Seven physiological indicators are derived and fed into the network together with three-channel rPPG signals. We also propose a novel strategy for training the models. For a fair and complete evaluation, we compile three massive datasets containing 1143 subjects and 2291 data. These datasets were collected under different scenarios: one from a school laboratory and the other two from two hospital departments. On the complete testing data, the proposed approach yields an MAE of 11.54 mmHg for SBP and 8.09 mmHg for DBP, outperforming previous studies.
- 8 April 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 71 (00189456) , 1-13
A Facial-Image-Based Blood Pressure Measurement System Without Calibration
Blood pressure (BP) is a major vital sign that is highly correlated with human health. However, for decades BP measurement has involved a cuff, which can be uncomfortable and even carry the risk of infection. The remote photoplethysmography (rPPG) technique has gained great success in heart rate monitoring for tackling these problems. Some studies integrate the pulse transit time (PTT) into the system and ask users put their hand beside their face. A calibration procedure is usually needed for such methods. Other methods measure the BP with several rPPG waveform features or the whole rPPG segment. However, these methods remain inconvenient, and few methods evaluate their algorithm with large enough datasets to be effective. Hence, we propose a calibration-free and facial-image-based blood pressure measurement system which takes a deep neural network as the backbone. Seven physiological indicators are derived and fed into the network together with three-channel rPPG signals. We also propose a novel strategy for training the models. For a fair and complete evaluation, we compile three massive datasets containing 1143 subjects and 2291 data. These datasets were collected under different scenarios: one from a school laboratory and the other two from two hospital departments. On the complete testing data, the proposed approach yields an MAE of 11.54 mmHg for SBP and 8.09 mmHg for DBP, outperforming previous studies.
- 24 September 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Biomedical and Health Informatics
- Vol. 25 (5) , 1397-1408
A Heart Rate Monitoring Framework for Real-World Drivers Using Remote Photoplethysmography
Remote photoplethysmography (rPPG) is an unobtrusive solution to heart rate monitoring in drivers. However, disturbances that occur during driving such as driver behavior, motion artifacts, and illuminance variation complicate the monitoring of heart rate. Faced with disturbance, one commonly used assumption is heart rate periodicity (or spectrum sparsity). Several methods improve stability at the expense of tracking sensitivity for heart rate variation. Based on statistical signal processing (SSP) and Monte Carlo simulations, the outlier probability is derived and ADaptive spectral filter banks (AD) is proposed as a new algorithm which provides an explicable tuning option for spectral filter banks to strike a balance between robustness and sensitivity in remote monitoring for driving scenarios. Moreover, we construct a driving database containing over 23 hours of data to verify the proposed algorithm. The influence on rPPG from driver habits (both amateurs and professionals), vehicle types (compact cars and buses), and routes are also evaluated. In comparison to state-of-the-art rPPG for driving scenarios, the mean absolute error in the Passengers, Compact Cars, and Buses scenarios is 3.43, 7.85, and 5.02 beats per minute, respectively.
- 24 September 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Biomedical and Health Informatics
- Vol. 25 (5) , 1397-1408
A Heart Rate Monitoring Framework for Real-World Drivers Using Remote Photoplethysmography
Remote photoplethysmography (rPPG) is an unobtrusive solution to heart rate monitoring in drivers. However, disturbances that occur during driving such as driver behavior, motion artifacts, and illuminance variation complicate the monitoring of heart rate. Faced with disturbance, one commonly used assumption is heart rate periodicity (or spectrum sparsity). Several methods improve stability at the expense of tracking sensitivity for heart rate variation. Based on statistical signal processing (SSP) and Monte Carlo simulations, the outlier probability is derived and ADaptive spectral filter banks (AD) is proposed as a new algorithm which provides an explicable tuning option for spectral filter banks to strike a balance between robustness and sensitivity in remote monitoring for driving scenarios. Moreover, we construct a driving database containing over 23 hours of data to verify the proposed algorithm. The influence on rPPG from driver habits (both amateurs and professionals), vehicle types (compact cars and buses), and routes are also evaluated. In comparison to state-of-the-art rPPG for driving scenarios, the mean absolute error in the Passengers, Compact Cars, and Buses scenarios is 3.43, 7.85, and 5.02 beats per minute, respectively.