Multiplex real-time PCR for diagnosing malaria in a non-endemic setting: a prospective comparison to conventional methods
Open Access
- 26 September 2018
- journal article
- research article
- Published by Springer Nature in European Journal of Clinical Microbiology & Infectious Diseases
- Vol. 37 (12) , 2323-2329
Abstract
Almost a decade ago our diagnostic laboratory implemented an in-house real-time PCR for the detection of Plasmodium DNA to diagnose malaria in parallel with conventional diagnostics, i.e., microscopy (thick and thin smears), quantitative buffy coat microscopy (QBC), and a rapid diagnostic test (RDT). Here we report our experiences and make a comparison between the different diagnostic procedures used in this non-endemic setting. All patients during the period February 2009–December 2017 suspected of malaria were prospectively tested at the moment of sample collection. Both PCR and conventional malaria diagnostics were carried out on a total of 839 specimens from 825 patients. In addition, three Plasmodium falciparum (Pf) patients were closely followed by real-time PCR and microscopy after treatment. Overall, 56 samples (55 patients) tested positive by real-time PCR, of which six were missed by microscopy and seven by QBC. RDT showed fairly good results in detecting Pf, whereas specificity was not optimal. RDT failed to detect 10 of 17 non-Pf PCR positive specimens. One Plasmodium malariae patient would have been missed if only conventional diagnostic tests had been used. The high sensitivity of the PCR was confirmed by the number of PCR positive, microscopy negative post-treatment samples. In conclusion, within our routine diagnostic setting, malaria real-time PCR not only showed a high level of agreement with the conventional methods used, but also showed higher sensitivity and better specificity. Still, for complete replacement of the conventional procedures in a non-endemic setting, the time-to-results of the real-time PCR is currently too long.Keywords
Funding Information
- Leiden University Medical Center
This publication has 16 references indexed in Scilit:
- Major Threat to Malaria Control Programs byPlasmodium falciparumLacking Histidine-Rich Protein 2, EritreaEmerging Infectious Diseases, 2018
- Diagnostic performance of the loop-mediated isothermal amplification (LAMP) based illumigene® malaria assay in a non-endemic regionMalaria Journal, 2017
- Increase in imported malaria in the Netherlands in asylum seekers and VFR travellersMalaria Journal, 2017
- Malaria diagnostics: now and the futureParasitology, 2014
- Malaria rapid diagnostic tests: challenges and prospectsJournal of Medical Microbiology, 2013
- Malaria rapid diagnostic tests in travel medicineClinical Microbiology and Infection, 2013
- Quantitative buffy coat (QBC) test for rapid diagnosis of malariaEuropean Journal of Pediatrics, 2011
- Multiplexed Real-Time PCR Assay for Discrimination of Plasmodium Species with Improved Sensitivity for Mixed InfectionsJournal of Clinical Microbiology, 2009
- PCR-based methods to the diagnosis of imported malariaParasite, 2008
- Plasmodium malariae infection in spite of previous anti-malarial medicationParasitology Research, 2007