The Optimal Cuff Width for Measuring Toe Blood Pressure
- 1 August 2007
- journal article
- research article
- Published by SAGE Publications in Angiology
- Vol. 58 (4) , 472-476
Abstract
To determine the optimal cuff width for measuring toe blood pressure in patients with lower limb ischemia, this experimental prospective study examined 20 patients with symptoms of peripheral arterial disease referred for vascular examination or vascular surgery. Toe blood pressure was measured hydrostatically by the pole test using cuffs of different widths. Pole test reflects the true physiological blood pressure value and was the reference method. Blood pressures obtained using the cuffs were related to this value and to patients' toe circumference. With the 2.5-cm cuff, the patients had a mean pole test toe blood pressure of 28 mm Hg (range, 6-55 mm Hg). Compared with pole test results, the toe blood pressure was 15.6 mm Hg (95% confidence interval [CI], 8-23 mm Hg) higher when measured using the 2.0-cm cuff (P < .001) and 4.5 mm Hg (95% CI, 0-9 mm Hg) higher when measured using the 2.5-cm cuff (P = .07). Using the 1.5-cm and 3.0-cm cuffs, the differences were 27.0 mm Hg (95% CI, 13-43 mm Hg) and −2.0 mm Hg (95% CI, −11 to 8 mm Hg), respectively. The cuff width greatly affects the obtained toe blood pressure value, and larger cuffs correspond better to the hydrostatic pressure. For clinical use and as a reporting standard, we propose that toe blood pressure measurements should be made using a 2.5-cm-wide cuff.Keywords
This publication has 9 references indexed in Scilit:
- The cuff width influences the toe blood pressure valueVasa, 2004
- Variation of Method for Measurement of Brachial Artery Pressure Significantly Affects Ankle–Brachial Pressure Index ValuesEuropean Journal of Vascular and Endovascular Surgery, 2000
- Objectives and methodology of the consensus processEuropean Journal of Vascular and Endovascular Surgery, 2000
- Falsely elevated ankle pressures in severe leg ischaemia: The pole test—An alternative approachEuropean Journal of Vascular Surgery, 1994
- The effect of body heating and cooling on the ankle and toe systolic pressures in arterial diseaseJournal of Vascular Surgery, 1992
- A team approach to diabetic foot care—the Manchester experienceThe Foot, 1991
- Ratio of cuff width/arm circumference as a determinant of arterial blood pressure measurements in adultsJournal of Internal Medicine, 1990
- Raised Ankle/Brachial Pressure Index in Insulin‐treated Diabetic PatientsDiabetic Medicine, 1989
- A laser Doppler technique for measuring distal blood‐pressure: a comparison with conventional strain‐gauge techniqueClinical Physiology and Functional Imaging, 1986