Hans-Ivar Påhlsson
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Hans-Ivar Påhlsson has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
E. Wahlberg
2 shared publicationsG. Jörneskog
2 shared publicationsAnna Andersson
Department of Molecular Medecine and Surgery, Karolinska Institute, Stockholm Sweden
1 shared publicationCarolina Laskar
Department of Molecular Medecine and Surgery, Karolinska Institute, Stockholm Sweden
1 shared publicationEric Wahlberg
Department of Molecular Medecine and Surgery, Karolinska Institute, Stockholm Sweden
1 shared publicationK. Lund
1 shared publication
Latest Publications
- 1 November 2008
- Published by Elsevier in European Journal of Vascular and Endovascular Surgery
- Vol. 36 (5) , 576-581
The Validity and Reliability of Automated and Manually Measured Toe Blood Pressure in Ischemic Legs of Diabetic Patients
- 1 November 2008
- Published by Elsevier in European Journal of Vascular and Endovascular Surgery
- Vol. 36 (5) , 576-581
The Validity and Reliability of Automated and Manually Measured Toe Blood Pressure in Ischemic Legs of Diabetic Patients
- 1 August 2007
- Published by SAGE Publications in Angiology
- Vol. 58 (4) , 472-476
The Optimal Cuff Width for Measuring Toe Blood Pressure
To determine the optimal cuff width for measuring toe blood pressure in patients with lower limb ischemia, this experimental prospective study examined 20 patients with symptoms of peripheral arterial disease referred for vascular examination or vascular surgery. Toe blood pressure was measured hydrostatically by the pole test using cuffs of different widths. Pole test reflects the true physiological blood pressure value and was the reference method. Blood pressures obtained using the cuffs were related to this value and to patients' toe circumference. With the 2.5-cm cuff, the patients had a mean pole test toe blood pressure of 28 mm Hg (range, 6-55 mm Hg). Compared with pole test results, the toe blood pressure was 15.6 mm Hg (95% confidence interval [CI], 8-23 mm Hg) higher when measured using the 2.0-cm cuff (P < .001) and 4.5 mm Hg (95% CI, 0-9 mm Hg) higher when measured using the 2.5-cm cuff (P = .07). Using the 1.5-cm and 3.0-cm cuffs, the differences were 27.0 mm Hg (95% CI, 13-43 mm Hg) and −2.0 mm Hg (95% CI, −11 to 8 mm Hg), respectively. The cuff width greatly affects the obtained toe blood pressure value, and larger cuffs correspond better to the hydrostatic pressure. For clinical use and as a reporting standard, we propose that toe blood pressure measurements should be made using a 2.5-cm-wide cuff.
- 1 August 2007
- Published by SAGE Publications in Angiology
- Vol. 58 (4) , 472-476
The Optimal Cuff Width for Measuring Toe Blood Pressure
To determine the optimal cuff width for measuring toe blood pressure in patients with lower limb ischemia, this experimental prospective study examined 20 patients with symptoms of peripheral arterial disease referred for vascular examination or vascular surgery. Toe blood pressure was measured hydrostatically by the pole test using cuffs of different widths. Pole test reflects the true physiological blood pressure value and was the reference method. Blood pressures obtained using the cuffs were related to this value and to patients' toe circumference. With the 2.5-cm cuff, the patients had a mean pole test toe blood pressure of 28 mm Hg (range, 6-55 mm Hg). Compared with pole test results, the toe blood pressure was 15.6 mm Hg (95% confidence interval [CI], 8-23 mm Hg) higher when measured using the 2.0-cm cuff (P < .001) and 4.5 mm Hg (95% CI, 0-9 mm Hg) higher when measured using the 2.5-cm cuff (P = .07). Using the 1.5-cm and 3.0-cm cuffs, the differences were 27.0 mm Hg (95% CI, 13-43 mm Hg) and −2.0 mm Hg (95% CI, −11 to 8 mm Hg), respectively. The cuff width greatly affects the obtained toe blood pressure value, and larger cuffs correspond better to the hydrostatic pressure. For clinical use and as a reporting standard, we propose that toe blood pressure measurements should be made using a 2.5-cm-wide cuff.
- 1 November 2004
- Published by Hogrefe Publishing Group in Vasa
- Vol. 33 (4) , 215-218
The cuff width influences the toe blood pressure value
Background: Toe blood pressure is a valuable and often used parameter when lower limb ischaemia is evaluated in patients with diabetes, but little has been done to standardise the method. The aim of this study was to evaluate if the cuff size influences the toe blood pressure values obtained in patients with diabetes. Patients and methods: Eleven patients with diabetes without a history of peripheral vascular disease, and six age matched healthy subjects were investigated. Their blood pressures were measured in the upper arm and at the ankle level repetitively. For measurement of toe blood pressure two different cuff widths were used. Results: All blood pressures were similar in patients and control subjects, as well as over time. The toe blood pressure values were 18 mmHg higher (p < 0.01) if measured with a 2.0-cm compared to a 2.5-cm wide cuff. There was a relationship (r = 0.63, p < 0.05 for patients) between toe circumference and the toe blood pressure value, where smaller halluxes gave lower values. Conclusions: The cuff width influences the obtained toe blood pressure value and needs to be considered when evaluating limb ischemia in patients with diabetes.
- 1 November 2004
- Published by Hogrefe Publishing Group in Vasa
- Vol. 33 (4) , 215-218
The cuff width influences the toe blood pressure value
Background: Toe blood pressure is a valuable and often used parameter when lower limb ischaemia is evaluated in patients with diabetes, but little has been done to standardise the method. The aim of this study was to evaluate if the cuff size influences the toe blood pressure values obtained in patients with diabetes. Patients and methods: Eleven patients with diabetes without a history of peripheral vascular disease, and six age matched healthy subjects were investigated. Their blood pressures were measured in the upper arm and at the ankle level repetitively. For measurement of toe blood pressure two different cuff widths were used. Results: All blood pressures were similar in patients and control subjects, as well as over time. The toe blood pressure values were 18 mmHg higher (p < 0.01) if measured with a 2.0-cm compared to a 2.5-cm wide cuff. There was a relationship (r = 0.63, p < 0.05 for patients) between toe circumference and the toe blood pressure value, where smaller halluxes gave lower values. Conclusions: The cuff width influences the obtained toe blood pressure value and needs to be considered when evaluating limb ischemia in patients with diabetes.