Modification of the wavelet method used in transiently evoked otoacoustic emission pass/fail criterion to increase its accuracy
Authors:
- 1 January 2002
- journal article
- research article
- Published by Springer Nature in Medical & Biological Engineering & Computing
- Vol. 40 (1) , 34-40
Abstract
Transiently evoked otoacoustic emissions (TEOAEs) are widely used in newborn hearing screening programmes for early detection of hearing losses. To increase the accuracy of a TEOAE pass/fail criterion that uses the wavelet method, it was demonstrated that the large estimation variance is a possible reason for the inaccuracy, and a modified wavelet method is proposed to solve the inaccuracy problem. In the modified wavelet method, N paired buffers, instead of only one, were used to store the total 512 subaveraged responses, and then the average of the calculated N cross-correlation coefficients between N pairs of TEOAE signals was taken in the pass/fail criterion. Four sets of 256 synthesised noise and eight sets of 256 synthesised noisy TEOAE signals were tested, and each set was tested 1000 times. The results showed that the standard deviation of the correlation estimation was greatly reduced by using this average value with N selected as 4. As a result, the total number of single-scale cross-correlation coefficients below 50% decreased from 1281 to 195 for noisy TEOAE signals, and the total number of single-scale cross-correlation coefficients above 50% decreased from 90 to 0 for synthesised noise.Keywords
This publication has 13 references indexed in Scilit:
- Data processing options and response scoring for OAE-based newborn hearing screeningThe Journal of the Acoustical Society of America, 2001
- Otoacoustic emissions and improved pass/fail separation using wavelet analysis and time windowingMedical & Biological Engineering & Computing, 2001
- Optimal Band Pass Filtering of Transient Evoked Otoacoustic Emissions in NeonatesInternational Journal of Audiology, 1999
- Evaluation of Click Evoked Otoacoustic Emissions in Newborns: Effects of Time-windowingInternational Journal of Audiology, 1999
- Effects of Background Noise on Click-Evoked Otoacoustic EmissionsEar & Hearing, 1998
- Time-Windowing of Click-Evoked Otoacoustic Emissions to Increase Signal-to-Noise RatioEar & Hearing, 1995
- The effects of noise in transient EOAE newborn hearing screeningInternational Journal of Pediatric Otorhinolaryngology, 1994
- Analysis of transient-evoked otoacoustic emissions in normal-hearing and hearing-impaired earsThe Journal of the Acoustical Society of America, 1993
- A Guide to the Effective Use of Otoacoustic EmissionsEar & Hearing, 1990
- Stimulated acoustic emissions from within the human auditory systemThe Journal of the Acoustical Society of America, 1978