SYShuenn-Tsong Young

Shuenn-Tsong Young

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Shuenn-Tsong Young has a total of 26 co-authors. Here are the top co-authors by number of shared publications:

  • L. -P. Yang

    Department of Electrical Engineering, National Taiwan University, Taipei, Taiwan

    2 shared publications
  • P. -C. Li

    National Yang-Ming University

    2 shared publications
  • T. -S. Kuo

    National Taiwan University

    2 shared publications
  • Cheng-Jung Wu

    Department of Speech and Hearing Disorders and Sciences, National Taipei College of Nursing, Taipei, Taiwan

    1 shared publication
  • H. K. Chiang

    Institute of Biomedical Engineering, National Yang-Ming University, Division of Experimental Surgery, Department of Surgery, Veterans General Hospital-Taipei, Taipei, Taiwan

    1 shared publication
  • J. -H. Lin

    Institute of Biomedical Engineering, National Yang-Ming University, Taipei, China

    1 shared publication

Latest Publications

  • Development of a Mandarin Monosyllable Recognition Test

    by Kuen-Shian Tsai, Li-Hui Tseng, Cheng-Jung Wu, Shuenn-Tsong Young

    Objective: This study aimed to develop a set of 50- and 25-item word lists that exhibited familiarity, homogeneity, and phonemic balance for a Mandarin monosyllable recognition test (MMRT). Design: To achieve the design goal of high subject familiarity with the test material, we selected the 700 most frequently occurring monosyllables to be the test material. The homogeneity of the test material was achieved by evaluating five psychometric characteristics of these 700 monosyllables to obtain 348 homogeneous monosyllables with similar psychometric functions for constructing the word lists. The phonemic balance of the 50-item word lists was achieved by deriving the desired numbers of initials, finals, and tones in these lists according to their occurrence frequencies in 4733 monosyllabic words. The phonemic balance of the 25-item word lists was achieved by equally dividing the desired numbers of initials, finals, and tones in the 50-item word lists into two groups, called half-A and half-B lists. Three half-A lists and three half-B lists were constructed from the 348 homogeneous monosyllables, and they could be paired to form nine 50-item word lists. Accordingly, all of the MMRT word lists are familiar, homogeneous, and phonemically balanced. Results: The homogeneity of the MMRT word lists was examined by evaluating the interlist equivalence, interitem variability, and intersubject variability. A χ2 test was used to evaluate the interlist equivalence among the MMRT word lists; that is, to determine whether the values of percent correct recognition were distributed identically at 12 different presentation levels among the six 25-item word lists and nine 50-item word lists. No statistically significant differences were found among the word lists: χ2(55) = 12.004 and p = 1.000 for the six 25-item word lists, χ2(88) = 7.695 and p = 1.000 for the nine 50-item word lists, and χ2(154) = 19.699 and p = 1.000 for the six 25-item word lists plus nine 50-item word lists. The χ2 tests indicated that the six 25-item word lists and nine 50-item word lists exhibited interlist equivalence. The mean interitem variability (2.0 dB) and mean intersubject variability (2.3 dB) are lower for the MMRT word lists than for previously reported word recognition tests. Conclusion: This study applied an innovative approach to design MMRT word lists from familiar and homogeneous monosyllables, in which the familiarity, homogeneity, and phonemic balance of the six 25-item and nine 50-item word lists were strictly controlled. These word lists exhibit interlist equivalence with respect to their psychometric functions and five psychometric characteristics; moreover, their interitem and intersubject variability are lower than those of previously reported lists. Future clinical experiments should examine whether such a design approach can improve the reliability and diagnostic sensitivity of word recognition tests for hearing-impaired listeners.


  • Genetic algorithm for the efficient selection of disyllabic word lists used in Mandarin speech discrimination tests

    by P. -C. Li, Y. -Y. Chiang, K. -S. Tsai, S. -T. Young

    Speech audiometric tests have been widely used for advanced hearing diagnoses and in rehabilitation. However, there are no standardised speech tests for more than 90% of the world's population, who do not speak English. A major problem in the design of a speech audiometric test is that the selection of test materials is subject to multiple criteria, and its complexity rises dramatically as the structure of test items changes from phonemic or monosyllabic forms to disyllabic or polysyllabic forms. A genetic algorithm is presented that can automatically select a set of disyllabic words from a large Mandarin corpus. The selection accords with the following principal criteria for the items constituting a speech discrimination test: similarity in structure, familiarity to the subjects, and a phonemically balanced composition. The performance of the genetic algorithm was evaluated by computation of the distance between a target vector, specifying the desired distribution of initial and final syllables and tone patterns for daily disyllabic word usage, and the vector derived by the search results of the algorithm. The use of the genetic algorithm was illustrated by its application to the selection of test lists from two Mandarin corpora. The results showed that, for a given corpus, at least 12 disyllabic word lists with a distance of less than 20 could be generated within 72 h. The genetic algorithm performed an efficient, robust and low-complexity search of the problem space and can be easily modified to adapt to the material selection of other languages.


  • Design considerations for an acoustic MEMS filter

    by S.-H. Shen, W. Fang, S.-T. Young


  • Rapid Prototyping Strategy for a Surgical Data Warehouse

    by S.-T. Tang, Y.-F. Huang, M.-L. Hsiao, S.-H. Yang, S.-T. Young

    Objectives: Healthcare processes typically generate an enormous volume of patient information. This information largely represents unexploited knowledge, since current hospital operational systems (e.g., HIS, RIS) are not suitable for knowledge exploitation. Data warehousing provides an attractive method for solving these problems, but the process is very complicated. This study presents a novel strategy for effectively implementing a healthcare data warehouse. Methods: This study adopted the rapid prototyping (RP) method, which involves intensive interactions. System developers and users were closely linked throughout the life cycle of the system development. The presence of iterative RP loops meant that the system requirements were increasingly integrated and problems were gradually solved, such that the prototype system evolved into the final operational system. Results: The results were analyzed by monitoring the series of iterative RP loops. First a definite workflow for ensuring data completeness was established, taking a patient-oriented viewpoint when collecting the data. Subsequently the system architecture was determined for data retrieval, storage, and manipulation. This architecture also clarifies the relationships among the novel system and legacy systems. Finally, a graphic user interface for data presentation was implemented. Conclusions: Our results clearly demonstrate the potential for adopting an RP strategy in the successful establishment of a healthcare data warehouse. The strategy can be modified and expanded to provide new services or support new application domains. The design patterns and modular architecture used in the framework will be useful in solving problems in different healthcare domains.


  • Effects of noise on transient-evoked oto-acoustic emission pass/fail criteria

    by L. -P. Yang, S. -T. Young, T. -S. Kuo

    This study investigated the effects of noise on typical transient-evoked oto-acoustic emission (TEOAE) pass/fail criteria. Different levels of synthesised noise were added to one TEOAE signal, to determine the relationship between the signal-to-noise ratio (SNR) and typical TEOAE parameters: reproducibility, TEOAE level and corrected TEOAE level. Results showed that, with the same TEOAE signal, if the SNR decreased from 19 dB to −7 dB, the means of estimated reproducibility decreased from 97% to 7%, and the means of estimated TEOAE levels were doubled. Only the means ofestimated corrected TEOAE levels were relatively insensitive to SNR. The standard deviations of all TEOAE parameter estimators increased with decreasing SNR. With these results, this study proposed that each typical TEOAE parameter alone should not be taken as the absolute pass/fail criterion. A combination of the corrected TEOAE level and the reproducibility would be better.


  • Modification of the wavelet method used in transiently evoked otoacoustic emission pass/fail criterion to increase its accuracy

    by L. -P. Yang, S. -T. Young, T. -S. Kuo

    Transiently evoked otoacoustic emissions (TEOAEs) are widely used in newborn hearing screening programmes for early detection of hearing losses. To increase the accuracy of a TEOAE pass/fail criterion that uses the wavelet method, it was demonstrated that the large estimation variance is a possible reason for the inaccuracy, and a modified wavelet method is proposed to solve the inaccuracy problem. In the modified wavelet method, N paired buffers, instead of only one, were used to store the total 512 subaveraged responses, and then the average of the calculated N cross-correlation coefficients between N pairs of TEOAE signals was taken in the pass/fail criterion. Four sets of 256 synthesised noise and eight sets of 256 synthesised noisy TEOAE signals were tested, and each set was tested 1000 times. The results showed that the standard deviation of the correlation estimation was greatly reduced by using this average value with N selected as 4. As a result, the total number of single-scale cross-correlation coefficients below 50% decreased from 1281 to 195 for noisy TEOAE signals, and the total number of single-scale cross-correlation coefficients above 50% decreased from 90 to 0 for synthesised noise.


    • 26 February 2000
      • Vol. 44  (1)

    Autostage sperm tracing system for semen evaluation.

    by Y L Kuo, W L Tzeng, P C Li, T S Tang, S T Young


  • New System for Long-Term Monitoring of Sperm Motility: Edta Effect on Semen

    by Y. L. Kuo, W. L. Tzeng, H. K. Chiang, R. F. Ni, T. C. Lee, S. T. Young

    Many drugs act as sperm stimulants and are of clinical value for male infertility. Current research deals with the physiological mechanisms of sperm motility/sperm stimulation and how long the effect lasts. For such a study, long-term monitoring of sperm motility becomes essential for traditional semen evaluation. A new system was designed to deal with the microscopic images of semen. Its performance was evaluated by studying the effect of EDTA on sperm motility. EDTA increased sperm curvilinear velocity (Vel) and straight-line velocity (Vei) by 31 and 20%. EDTA also prolonged the duration of motility by 68 and 61%, respectively. However, EDTA had less effect on the linearity of forward progression (Lin). The proposed system can analyze semen and does well at monitoring sperm motility for short term and long term. It may be valuable to test the possible role of sperm stimulation for male infertility and assisted reproduction.