A multinebulization technique for the determination of trace metals in a marine biota sample by on-line isotope dilution inductively coupled plasma mass spectrometry (OID-ICP-MS)
- 18 August 2020
- journal article
- research article
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 35 (11) , 2509-2516
Abstract
A new concept of nebulizer (i.e., multinebulizer) has been employed for trace elements (e.g., Cd, Cu, Hg, Ni, Pb, and Zn) determination in marine biota sample (e.g., fish sample). To this end, an analytical methodology based on the combination of a multinebulizer with isotope dilution (ID) calibration strategy and inductively coupled plasma mass spectrometry (ICP-MS) has been proposed. In this way, the on-line isotope dilution (OID) is accomplished by the simultaneous introduction of the liquid samples/standard and the isotopic reference solution (i.e., spike) into the plasma with an efficient mixing between them, which takes place at the inner cavity of the multinebulizer tip. The proposed OID-ICP-MS analytical methodology allows the fast determination of Cd, Cu, Hg, Ni, Pb and Zn in a biota sample certified reference material (CRM) (e.g., IAEA-476) with a limit of detection of 0.006, 0.4, 0.09, 30, 0.2 and 4 ng g-1, respectively, and recovery values ranging from 97 to 103 %. The primary advantage offered by the proposed analytical methodology is that the time-consuming spiking step in the conventional IDA is avoided. This yields savings in both total time and cost of the analysis per sample. Hence, it has been proved that the OID-ICP-MS using the multinebulizer is a promising solution for the trace element analysis of samples with high matrix content, which simplifies operation and significantly increases sample throughput and productivity.Keywords
Funding Information
- Ministerio de Economía y Competitividad (CTQ2016-79991-R)
- Universidad de Alicante (UAUST119-05)
This publication has 26 references indexed in Scilit:
- On-line species-unspecific isotope dilution analysis in the picomolar range reveals the time- and species-depending mercury uptake in human astrocytesAnalytical and Bioanalytical Chemistry, 2014
- Fraction-related quantification of silver nanoparticlesvia on-line species-unspecific post-channel isotope dilution in combination with asymmetric flow-field-flow fractionation (AF4)/sector field ICP-mass spectrometry (ICP-SF-MS)Journal of Analytical Atomic Spectrometry, 2013
- HPLC/ICP-MS in Combination with “Reverse” Online Isotope Dilution in Drug Metabolism StudiesAnalytical Chemistry, 2012
- Lead isotopes in environmental sciences: A reviewEnvironment International, 2008
- Isotope dilution with ICP-MS—simplified uncertainty estimation using a robust procedure based on a higher target value of uncertaintyJournal of Analytical Atomic Spectrometry, 2005
- Isotope-dilution ICP?MS for trace element determination and speciation: from a reference method to a routine method?Analytical and Bioanalytical Chemistry, 2004
- Evaluation of detector dead time calculation models for ICP-MSJournal of Analytical Atomic Spectrometry, 2001
- An experimental study of the behaviour of several elements in inductively coupled plasma mass spectrometry using the single-bore high-pressure pneumatic nebulizerSpectrochimica Acta Part B: Atomic Spectroscopy, 1995
- ‘Zone model’ as an explanation for signal behaviour and non-spectral interferences in inductively coupled plasma mass spectrometryJournal of Analytical Atomic Spectrometry, 1993
- Sample analysis by on-line isotope dilution inductively coupled plasma mass spectrometryJournal of Analytical Atomic Spectrometry, 1989