MGMiriam García

Miriam García

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Miriam García has a total of 5 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • A multinebulization technique for the determination of trace metals in a marine biota sample by on-line isotope dilution inductively coupled plasma mass spectrometry (OID-ICP-MS)

    by Miriam García, Miguel Ángel Aguirre, Emilia Vassileva, Antonio Canals

    A new concept of nebulizer (i.e., multinebulizer) has been employed for trace elements (e.g., Cd, Cu, Hg, Ni, Pb, and Zn) determination in marine biota sample (e.g., fish sample). To this end, an analytical methodology based on the combination of a multinebulizer with isotope dilution (ID) calibration strategy and inductively coupled plasma mass spectrometry (ICP-MS) has been proposed. In this way, the on-line isotope dilution (OID) is accomplished by the simultaneous introduction of the liquid samples/standard and the isotopic reference solution (i.e., spike) into the plasma with an efficient mixing between them, which takes place at the inner cavity of the multinebulizer tip. The proposed OID-ICP-MS analytical methodology allows the fast determination of Cd, Cu, Hg, Ni, Pb and Zn in a biota sample certified reference material (CRM) (e.g., IAEA-476) with a limit of detection of 0.006, 0.4, 0.09, 30, 0.2 and 4 ng g-1, respectively, and recovery values ranging from 97 to 103 %. The primary advantage offered by the proposed analytical methodology is that the time-consuming spiking step in the conventional IDA is avoided. This yields savings in both total time and cost of the analysis per sample. Hence, it has been proved that the OID-ICP-MS using the multinebulizer is a promising solution for the trace element analysis of samples with high matrix content, which simplifies operation and significantly increases sample throughput and productivity.


  • A new multinebulizer for spectrochemical analysis: wear metal determination in used lubricating oils by on-line standard dilution analysis (SDA) using inductively coupled plasma optical emission spectrometry (ICP OES)

    by Miriam García, Miguel Ángel Aguirre, Antonio Canals

    A new multinebulizer has been employed for wear metal (e.g., Cd, Cr, Cu, Fe, Mn, Ni, and Pb) determination in used lubricating oils. To this end, a multinebulizer-based analytical methodology combined with on-line standard dilution analysis (on-line SDA) and inductively coupled plasma optical emission spectrometry (ICP OES) (multinebulizer/SDA/ICP OES) has been proposed, which is able to overcome typical limitations related to organic sample analysis by ICP-based techniques. This is accomplished by the simultaneous introduction of organic samples and aqueous calibration standards, with a minimal sample pretreatment (i.e., dilution). The multinebulizer/SDA/ICP OES combination allows the determination of Cd, Cr, Cu, Fe, Mn, Ni and Pb in used lubricating oils with a limit of detection of 20, 10, 6, 20, 4, 30 and 200 ng g−1, respectively. The subsequent analysis of spiked commercial lubricating oil samples has led to recovery values which range from 91 to 108%. The efficiency of the proposed methodology has been checked by comparing its results with values obtained with conventional standard addition calibration and both limits of detection and recovery values were of the same order of magnitude. The proposed analytical methodology has the main advantage of ease of operation, as time and cost of analysis are reduced and the use of organic calibration standards is also avoided. Hence, the synergistic association multinebulizer/SDA is a simple, fast, relatively economic, environmentally friendly, direct and reliable method of wear metal monitoring in used lubricating oils by ICP OES.


  • Determination of As, Se, and Hg in fuel samples by in-chamber chemical vapor generation ICP OES using a Flow Blurring® multinebulizer

    by Miriam García, Miguel Ángel Aguirre, Antonio Canals

    In this work, a new and simple analytical methodology based on in-chamber chemical vapor generation has been developed for the spectrochemical analysis of commercial fuel samples. A multiple nebulizer with three nebulization units has been employed for this purpose: One unit was used for sample introduction, while the other two were used for the necessary reagent introduction. In this way, the aerosols were mixed inside the spray chamber. Through this method, analyte transport and, therefore, sensitivity are improved in inductively coupled plasma-optical emission spectrometry. The factors (i.e., variables), influencing chemical vapor generation, have been optimized using a multivariate approach. Under optimum chemical vapor generation conditions ([NaBH4] = 1.39%, [HCl] = 2.97 M, total liquid flow = 936 μL min−1), the proposed sample introduction system allowed the determination of arsenic, selenium, and mercury up to 5 μg g−1 with a limit of detection of 25, 140, and 13 μg kg−1, respectively. Analyzing spiked commercial fuel samples, recovery values obtained were between 96 and 113%, and expanded uncertainty values ranged from 4 to 16%. The most striking practical conclusion of this investigation is that no carbon deposit appears on the plasma torch after extended periods of working. A new and simple analytical methodology based on in-chamber chemical vapor generation has been developed for the spectrochemical analysis of commercial fuel samples in ICP OES