Temporal convolutional networks predict dynamic oxygen uptake response from wearable sensors across exercise intensities
Open Access
- 11 November 2021
- journal article
- research article
- Published by Springer Nature in npj Digital Medicine
- Vol. 4 (1) , 1-8
Abstract
Oxygen consumption ( $$\dot{\,{{\mbox{V}}}}{{{\mbox{O}}}}_{2}$$ ) provides established clinical and physiological indicators of cardiorespiratory function and exercise capacity. However, $$\dot{\,{{\mbox{V}}}}{{{\mbox{O}}}}_{2}$$ monitoring is largely limited to specialized laboratory settings, making its widespread monitoring elusive. Here we investigate temporal prediction of $$\dot{\,{{\mbox{V}}}}{{{\mbox{O}}}}_{2}$$ from wearable sensors during cycle ergometer exercise using a temporal convolutional network (TCN). Cardiorespiratory signals were acquired from a smart shirt with integrated textile sensors alongside ground-truth $$\dot{\,{{\mbox{V}}}}{{{\mbox{O}}}}_{2}$$ from a metabolic system on 22 young healthy adults. Participants performed one ramp-incremental and three pseudorandom binary sequence exercise protocols to assess a range of $$\dot{\,{{\mbox{V}}}}{{{\mbox{O}}}}_{2}$$ dynamics. A TCN model was developed using causal convolutions across an effective history length to model the time-dependent nature of $$\dot{\,{{\mbox{V}}}}{{{\mbox{O}}}}_{2}$$ . Optimal history length was determined through minimum validation loss across hyperparameter values. The best performing model encoded 218 s history length (TCN-VO2 A), with 187, 97, and 76 s yielding <3% deviation from the optimal validation loss. TCN-VO2 A showed strong prediction accuracy (mean, 95% CI) across all exercise intensities (−22 ml min−1, [−262, 218]), spanning transitions from low–moderate (−23 ml min−1, [−250, 204]), low–high (14 ml min−1, [−252, 280]), ventilatory threshold–high (−49 ml min−1, [−274, 176]), and maximal (−32 ml min−1, [−261, 197]) exercise. Second-by-second classification of physical activity across 16,090 s of predicted $$\dot{\,{{\mbox{V}}}}{{{\mbox{O}}}}_{2}$$ was able to discern between vigorous, moderate, and light activity with high accuracy (94.1%). This system enables quantitative aerobic activity monitoring in non-laboratory settings, when combined with tidal volume and heart rate reserve calibration, across a range of exercise intensities using wearable sensors for monitoring exercise prescription adherence and personal fitness.
Keywords
All Related Versions
Funding Information
- Gouvernement du Canada | Natural Sciences and Engineering Research Council of Canada (PDF-503038-2017, RGPIN-6473)
- Gouvernement du Canada | Canadian Institutes of Health Research (201911FBD-434513-72081)
This publication has 44 references indexed in Scilit:
- Influence of exercise intensity on pulmonary oxygen uptake kinetics in young and late middle-aged adultsAmerican Journal of Physiology-Regulatory, Integrative and Comparative Physiology, 2012
- Relationship between oxygen consumption kinetics and BODE Index in COPD patientsInternational Journal of Chronic Obstructive Pulmonary Disease, 2012
- Clinical recommendations for cardiopulmonary exercise testing data assessment in specific patient populationsEuropean Heart Journal, 2012
- Oxygen Uptake Kinetics2012
- Endurance exercise performance: the physiology of championsThe Journal of Physiology, 2008
- Agreement Between Methods of Measurement with Multiple Observations Per IndividualJournal of Biopharmaceutical Statistics, 2007
- Effects of Training Status and Exercise Intensity on Phase II &OV0312;O2 KineticsMedicine & Science in Sports & Exercise, 2004
- Prognostic significance of oxygen uptake kinetics during low level exercise in patients with heart failureThe American Journal of Cardiology, 1999
- Coupling of ventilation and gas exchange during transitions in work rate by humansRespiration Physiology, 1995
- Value of peak exercise oxygen consumption for optimal timing of cardiac transplantation in ambulatory patients with heart failure.Circulation, 1991