RARobert Amelard

Robert Amelard

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Robert Amelard has a total of 4 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Temporal convolutional networks predict dynamic oxygen uptake response from wearable sensors across exercise intensities

    by Robert Amelard, Eric T. Hedge, Richard L. Hughson

    Oxygen consumption ( $$\dot{\,{{\mbox{V}}}}{{{\mbox{O}}}}_{2}$$ V ̇ O 2 ) provides established clinical and physiological indicators of cardiorespiratory function and exercise capacity. However, $$\dot{\,{{\mbox{V}}}}{{{\mbox{O}}}}_{2}$$ V ̇ O 2 monitoring is largely limited to specialized laboratory settings, making its widespread monitoring elusive. Here we investigate temporal prediction of $$\dot{\,{{\mbox{V}}}}{{{\mbox{O}}}}_{2}$$ V ̇ O 2 from wearable sensors during cycle ergometer exercise using a temporal convolutional network (TCN). Cardiorespiratory signals were acquired from a smart shirt with integrated textile sensors alongside ground-truth $$\dot{\,{{\mbox{V}}}}{{{\mbox{O}}}}_{2}$$ V ̇ O 2 from a metabolic system on 22 young healthy adults. Participants performed one ramp-incremental and three pseudorandom binary sequence exercise protocols to assess a range of $$\dot{\,{{\mbox{V}}}}{{{\mbox{O}}}}_{2}$$ V ̇ O 2 dynamics. A TCN model was developed using causal convolutions across an effective history length to model the time-dependent nature of $$\dot{\,{{\mbox{V}}}}{{{\mbox{O}}}}_{2}$$ V ̇ O 2 . Optimal history length was determined through minimum validation loss across hyperparameter values. The best performing model encoded 218 s history length (TCN-VO2 A), with 187, 97, and 76 s yielding <3% deviation from the optimal validation loss. TCN-VO2 A showed strong prediction accuracy (mean, 95% CI) across all exercise intensities (−22 ml min−1, [−262, 218]), spanning transitions from low–moderate (−23 ml min−1, [−250, 204]), low–high (14 ml min−1, [−252, 280]), ventilatory threshold–high (−49 ml min−1, [−274, 176]), and maximal (−32 ml min−1, [−261, 197]) exercise. Second-by-second classification of physical activity across 16,090 s of predicted $$\dot{\,{{\mbox{V}}}}{{{\mbox{O}}}}_{2}$$ V ̇ O 2 was able to discern between vigorous, moderate, and light activity with high accuracy (94.1%). This system enables quantitative aerobic activity monitoring in non-laboratory settings, when combined with tidal volume and heart rate reserve calibration, across a range of exercise intensities using wearable sensors for monitoring exercise prescription adherence and personal fitness.


  • Open Access

    Temporal convolutional networks predict dynamic oxygen uptake response from wearable sensors across exercise intensities

    by Robert Amelard, Eric T Hedge, Richard L Hughson

    Oxygen consumption (VO$_2$) provides established clinical and physiological indicators of cardiorespiratory function and exercise capacity. However, VO$_2$ monitoring is largely limited to specialized laboratory settings, making its widespread monitoring elusive. Here, we investigate temporal prediction of VO$_2$ from wearable sensors during cycle ergometer exercise using a temporal convolutional network (TCN). Cardiorespiratory signals were acquired from a smart shirt with integrated textile sensors alongside ground-truth VO$_2$ from a metabolic system on twenty-two young healthy adults. Participants performed one ramp-incremental and three pseudorandom binary sequence exercise protocols to assess a range of VO$_2$ dynamics. A TCN model was developed using causal convolutions across an effective history length to model the time-dependent nature of VO$_2$. Optimal history length was determined through minimum validation loss across hyperparameter values. The best performing model encoded 218 s history length (TCN-VO$_2$ A), with 187 s, 97 s, and 76 s yielding less than 3% deviation from the optimal validation loss. TCN-VO$_2$ A showed strong prediction accuracy (mean, 95% CI) across all exercise intensities (-22 ml.min$^{-1}$, [-262, 218]), spanning transitions from low-moderate (-23 ml.min$^{-1}$, [-250, 204]), low-high (14 ml.min$^{-1}$, [-252, 280]), ventilatory threshold-high (-49 ml.min$^{-1}$, [-274, 176]), and maximal (-32 ml.min$^{-1}$, [-261, 197]) exercise. Second-by-second classification of physical activity across 16090 s of predicted VO$_2$ was able to discern between vigorous, moderate, and light activity with high accuracy (94.1%). This system enables quantitative aerobic activity monitoring in non-laboratory settings across a range of exercise intensities using wearable sensors for monitoring exercise prescription adherence and personal fitness.