Design and verification of 5-channel 1.5T knee joint receiving coil based on wearable technology
- 18 September 2020
- journal article
- research article
- Published by SAGE Publications in Technology and Health Care
- Vol. 28 (5) , 495-505
Abstract
BACKGROUND: Over the past 20 years, magnetic resonance receiving coil technology has developed rapidly. The traditional, commercial knee joint coil has a fixed mechanical structure. To meet the imaging needs of most patients, it is necessary to ensure that the mechanical geometry of the coil is as large as possible. Therefore, different quality images can be obtained by filling coefficients under loads of knees of different sizes. Lufkin et al. [1] have demonstrated that the signal-to-noise ratio (SNR) of coil imaging is directly proportional to its filling coefficient, which is S/N≈QL*η. Thus, the pursuit of an optimal coil filling coefficient is an important way to improve the coil imaging quality. OBJECTIVE: This study combines wearable concepts and coil development techniques and applies flexible and elastic materials to coil designs. METHODS: We used an elastic material instead of the traditional fixed mechanical structure to develop a 1.5T 5-channel knee joint receiving coil that can be attached to knee joints of different sizes within a certain range, allowing the coil to achieve a maximum filling coefficient under the loads of knees of different sizes. RESULTS: Compared to commercial 8-channel knee coils, the phantom test and clinical knee joint imaging demonstrated that the SNR of the developed coil increased by four times in the shallow layer and two times in the deep layer, under different load conditions. CONCLUSION: This high SNR performance demonstrates potential for the realization of high resolution and fast imaging sequences in knee imaging.Keywords
This publication has 11 references indexed in Scilit:
- RF Surface Receive Array Coils: The Art of an LC CircuitJournal of Magnetic Resonance Imaging, 2013
- A 64‐channel 3T array coil for accelerated brain MRIMagnetic Resonance in Medicine, 2012
- Stretchable coil arrays: Application to knee imaging under varying flexion anglesMagnetic Resonance in Medicine, 2011
- An MRI Receiver Coil Produced by Inkjet Printing Directly on to a Flexible SubstrateIEEE Transactions on Medical Imaging, 2010
- Mechanically adjustable coil array for wrist MRIMagnetic Resonance in Medicine, 2009
- 128‐channel body MRI with a flexible high‐density receiver‐coil arrayJournal of Magnetic Resonance Imaging, 2008
- Inkjet printing as a deposition and patterning tool for polymers and inorganic particlesSoft Matter, 2008
- Direct ink-jet printing and low temperature conversion of conductive silver patternsJournal of Materials Science, 2006
- 32‐channel 3 Tesla receive‐only phased‐array head coil with soccer‐ball element geometryMagnetic Resonance in Medicine, 2006
- The NMR phased arrayMagnetic Resonance in Medicine, 1990