  • Design and verification of 5-channel 1.5T knee joint receiving coil based on wearable technology

    by Gui Hao Li, Ye Li, Gai Yan Zhu, Tai Yu Yan, Xia Fei Hu, Tao Zhang, Shuang Zhang

    BACKGROUND: Over the past 20 years, magnetic resonance receiving coil technology has developed rapidly. The traditional, commercial knee joint coil has a fixed mechanical structure. To meet the imaging needs of most patients, it is necessary to ensure that the mechanical geometry of the coil is as large as possible. Therefore, different quality images can be obtained by filling coefficients under loads of knees of different sizes. Lufkin et al. [1] have demonstrated that the signal-to-noise ratio (SNR) of coil imaging is directly proportional to its filling coefficient, which is S/N≈QL*η. Thus, the pursuit of an optimal coil filling coefficient is an important way to improve the coil imaging quality. OBJECTIVE: This study combines wearable concepts and coil development techniques and applies flexible and elastic materials to coil designs. METHODS: We used an elastic material instead of the traditional fixed mechanical structure to develop a 1.5T 5-channel knee joint receiving coil that can be attached to knee joints of different sizes within a certain range, allowing the coil to achieve a maximum filling coefficient under the loads of knees of different sizes. RESULTS: Compared to commercial 8-channel knee coils, the phantom test and clinical knee joint imaging demonstrated that the SNR of the developed coil increased by four times in the shallow layer and two times in the deep layer, under different load conditions. CONCLUSION: This high SNR performance demonstrates potential for the realization of high resolution and fast imaging sequences in knee imaging.


  • Resolving phase ambiguity in dual‐echo dixon imaging using a projected power method

    by Tao Zhang, Yuxin Chen, Shanshan Bao, Marcus T. Alley, John M. Pauly, Brian A. Hargreaves, Shreyas S. Vasanawala

    Purpose To develop a fast and robust method to resolve phase ambiguity in dual‐echo Dixon imaging. Methods A major challenge in dual‐echo Dixon imaging is to estimate the phase error resulting from field inhomogeneity. In this work, a binary quadratic optimization program was formulated to resolve the phase ambiguity. A projected power method was developed to efficiently solve the optimization problem. Both the 1‐peak fat model and 6‐peak fat model were applied to three‐dimensional (3D) datasets. Additionally, the proposed method was extended to dynamic magnetic resonance imaging (MRI) applications using the 6‐peak fat model. With institutional review board (IRB) approval and patient consent/assent, the proposed method was evaluated and compared with region growing on 29 consecutive 3D high‐resolution patient datasets. Results Fast and robust water/fat separation was achieved by the proposed method in different representative 3D datasets and dynamic 3D datasets. Superior water/fat separation was achieved using the 6‐peak fat model compared with the 1‐peak fat model. Compared to region growing, the proposed method reduced water/fat swaps from 76 to 7% of the patient cohort. Conclusion The proposed method can achieve fast and robust phase error estimation in dual‐echo Dixon imaging. Magn Reson Med 77:2066–2076, 2017. © 2016 International Society for Magnetic Resonance in Medicine


  • Hybrid-Space SENSE Reconstruction for Simultaneous Multi-Slice MRI

    by Kangrong Zhu, Robert F. Dougherty, Hua Wu, Matthew J. Middione, Atsushi M. Takahashi, Tao Zhang, John M. Pauly, Adam B. Kerr

    Simultaneous Multi-Slice (SMS) magnetic resonance imaging (MRI) is a rapidly evolving technique for increasing imaging speed. Controlled aliasing techniques utilize periodic undersampling patterns to help mitigate the loss in signal-to-noise ratio (SNR) in SMS MRI. To evaluate the performance of different undersampling patterns, a quantitative description of the image SNR loss is needed. Additionally, eddy current effects in echo planar imaging (EPI) lead to slice-specific Nyquist ghosting artifacts. These artifacts cannot be accurately corrected for each individual slice before or after slice-unaliasing. In this work, we propose a hybrid-space sensitivity encoding (SENSE) reconstruction framework for SMS MRI by adopting a three-dimensional representation of the SMS acquisition. Analytical SNR loss maps are derived for SMS acquisitions with arbitrary phase encoding undersampling patterns. Moreover, we propose a matrix-decoding correction method that corrects the slice-specific Nyquist ghosting artifacts in SMS EPI acquisitions. Brain images demonstrate that the proposed hybrid-space SENSE reconstruction generates images with comparable quality to commonly used split-slice-generalized autocalibrating partially parallel acquisition reconstruction. The analytical SNR loss maps agree with those calculated by a Monte Carlo based method, but require less computation time for high quality maps. The analytical maps enable a fair comparison between the performances of coherent and incoherent SMS undersampling patterns. Phantom and brain SMS EPI images show that the matrix-decoding method performs better than the single-slice and slice-averaged Nyquist ghosting correction methods under the hybrid-space SENSE reconstruction framework.


  • Robust self‐navigated body MRI using dense coil arrays

    by Tao Zhang, Joseph Y. Cheng, Yuxin Chen, Dwight G. Nishimura, John M. Pauly, Shreyas S. Vasanawala

    Purpose: To develop a robust motion estimation method for free‐breathing body MRI using dense coil arrays.Methods: Self‐navigating pulse sequences can measure subject motion without using external motion monitoring devices. With dense coil arrays, individual coil elements can provide localized motion estimates. An averaged motion estimate over all coils is often used for motion compensation. However, this motion estimate may not accurately represent the dominant motion within the imaging volume. In this work, a coil clustering method is proposed to automatically determine the dominant motion for dense coil arrays. The feasibility of the proposed method is investigated in free‐breathing abdominal MRI and cardiac MRI, and compared with manual motion estimate selection for respiratory motion estimation and electrocardiography for cardiac motion estimation.Results: Automated motion estimation achieved similar respiratory motion estimation compared to manual selection (averaged correlation coefficient 0.989 and 0.988 for abdominal MRI and cardiac MRI, respectively), and accurate cardiac triggering compared to electrocardiography (averaged temporal variability 17.5 ms).Conclusion: The proposed method can provide accurate automated motion estimation for body MRI using dense coil arrays. It can enable self‐navigated free‐breathing abdominal and cardiac MRI without the need for external motion monitoring devices. Magn Reson Med 76:197–205, 2016.


  • Clinical performance of a free-breathing spatiotemporally accelerated 3-D time-resolved contrast-enhanced pediatric abdominal MR angiography

    by Tao Zhang, Ufra Yousaf, Albert Hsiao, Joseph Y. Cheng, Marcus T. Alley, Michael Lustig, John M. Pauly, Shreyas S. Vasanawala

    Background Pediatric contrast-enhanced MR angiography is often limited by respiration, other patient motion and compromised spatiotemporal resolution. Objective To determine the reliability of a free-breathing spatiotemporally accelerated 3-D time-resolved contrast-enhanced MR angiography method for depicting abdominal arterial anatomy in young children. Materials and methods With IRB approval and informed consent, we retrospectively identified 27 consecutive children (16 males and 11 females; mean age: 3.8 years, range: 14 days to 8.4 years) referred for contrast-enhanced MR angiography at our institution, who had undergone free-breathing spatiotemporally accelerated time-resolved contrast-enhanced MR angiography studies. A radio-frequency-spoiled gradient echo sequence with Cartesian variable density k-space sampling and radial view ordering, intrinsic motion navigation and intermittent fat suppression was developed. Images were reconstructed with soft-gated parallel imaging locally low-rank method to achieve both motion correction and high spatiotemporal resolution. Quality of delineation of 13 abdominal arteries in the reconstructed images was assessed independently by two radiologists on a five-point scale. Ninety-five percent confidence intervals of the proportion of diagnostically adequate cases were calculated. Interobserver agreements were also analyzed. Results Eleven out of 13 arteries achieved acceptable image quality (mean score range: 3.9-5.0) for both readers. Fair to substantial interobserver agreement was reached on nine arteries. Conclusion Free-breathing spatiotemporally accelerated 3-D time-resolved contrast-enhanced MR angiography frequently yields diagnostic image quality for most abdominal arteries in young children.


  • Open Access

    Coil compression for accelerated imaging with Cartesian sampling

    by Tao Zhang, John M. Pauly, Shreyas S. Vasanawala, Michael Lustig

    MRI using receiver arrays with many coil elements can provide high signal‐to‐noise ratio and increase parallel imaging acceleration. At the same time, the growing number of elements results in larger datasets and more computation in the reconstruction. This is of particular concern in 3D acquisitions and in iterative reconstructions. Coil compression algorithms are effective in mitigating this problem by compressing data from many channels into fewer virtual coils. In Cartesian sampling there often are fully sampledk‐space dimensions. In this work, a new coil compression technique for Cartesian sampling is presented that exploits the spatially varying coil sensitivities in these nonsubsampled dimensions for better compression and computation reduction. Instead of directly compressing ink‐space, coil compression is performed separately for each spatial location along the fully sampled directions, followed by an additional alignment process that guarantees the smoothness of the virtual coil sensitivities. This important step provides compatibility with autocalibrating parallel imaging techniques. Its performance is not susceptible to artifacts caused by a tight imaging field‐of‐view. High quality compression of in vivo 3D data from a 32 channel pediatric coil into six virtual coils is demonstrated. Magn Reson Med, 2013.