The photo-transferred thermoluminescence phenomenon in case of emergency dose assessment
Open Access
- 22 February 2020
- journal article
- research article
- Published by Springer Nature in Radiation and Environmental Biophysics
- Vol. 59 (2) , 331-336
Abstract
A major disadvantage of dose reconstruction by means of thermoluminescence (TL) is the fact that during readout of any TL material exposed to ionizing radiation (i.e., during measuring the glow curve), the radiation-induced signal gets lost. Application of the photo-transferred thermoluminescence phenomenon (PTTL) may offer a solution to this problem. In PTTL, the residual signal that is not destroyed by conventional TL readout (because it comes from deeper electron traps) can be readout through simultaneous stimulation by UV light and heating, allowing to obtain information about the absorbed dose in a second run. The present paper describes the application of PTTL for emergency dose assessment. For this, MTS-N thermoluminescent detectors (LiF: Mg, Ti) were exposed using a high-energy Clinac 2300 medical linear accelerator to doses of 100 mGy, 300 mGy, 500 mGy, 700 mGy and 1000 mGy. Irradiation with UV radiation allowed the determination of the optimal heating time of 3 h, while the optimal temperature was identified to be 70 °C. The results obtained demonstrated the usefulness of the PTTL method for emergency dose assessment. The efficiency of the PTTL method was determined as 19%. Finally it was found that the detector background after UV exposure should not be underestimated during routine dose measurements.Keywords
Funding Information
- Ministerstwo Nauki i Szkolnictwa Wyższego (B 181 150 000 1916.02)
This publication has 12 references indexed in Scilit:
- Application of phototransferred thermoluminescence (PTTL) for dose re-assessment in routine dosimetry using MTS-N (LiF:Mg,Ti) thermoluminescent detectorsRadiation Measurements, 2014
- Dose reassessment by using PTTL method in MTS-N (LiF:Mg, Ti) thermoluminescent detectorsRadiation Measurements, 2013
- Reassessment of doses in TLD-100 after long storage timesRadiation Measurements, 2008
- On the reassessment of doses in TL-dosimetry by measuring the residual doseRadiation Protection Dosimetry, 2006
- Application of Individually Calibrated Solid LiF,Ti (MTS-N) Detectors in Clinical DosimetryRadiation Protection Dosimetry, 1999
- PTTL Dose Re-estimation Applied to Quality Control in TLD-100 Based Personal DosimetryRadiation Protection Dosimetry, 1999
- Phototransferred thermoluminescenceJournal of Physics D: Applied Physics, 1998
- The time and wavelength response of phototransferred thermoluminescence in natural and synthetic quartzRadiation Measurements, 1997
- A Simple UV Irradiator for Low Dose Reassessment with LiF TLD-100Radiation Protection Dosimetry, 1996
- Application of Glow Curve Analysis Methods to Improve TLD-100 Dose Reassessment PerformanceHealth Physics, 1992