Małgorzata Wrzesień
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Małgorzata Wrzesień has a total of 29 co-authors. Here are the top co-authors by number of shared publications:
- Jurek Olszewski
Clinic of Otolaryngology, Laryngological Oncology, Audiology and Phoniatrics at the 2nd Department of Otolaryngology of the Medical University of Lodz, Department of Polish Dialectology and Logopedics of the University of Lodz, Poland
10 shared publications - Łukasz Albiniak
University of Lodz
8 shared publications J. Jankowski
Department of Nuclear Physics and Radiation Safety , University of Lodz , Pomorska 149/153, 90-236 Lodz , Poland 2 Department of Radiation Protection , Nofer Institute of Occupational Medicine , Teresy 8, 91-348 Lodz , Poland
2 shared publicationsKatarzyna Napolska
PET/CT Laboratory, Medical Diagnostic Centre VOXEL, Polnocna 42, Lodz 91-425, Poland
2 shared publicationsArkadiusz Jeziorski
Department of Surgical Oncology, Medical University of Lodz, Lodz, Poland
1 shared publication- Arkadiusz Jeziorski
Medical University of Lodz
1 shared publication
Latest Publications
- Open Access
- 1 September 2026
- Published by Walter de Gruyter GmbH in Polish Journal of Medical Physics And Engineering
- Vol. 32 (3) , 138-145
Analysis of 177 Lu-DOTATATE injection methods and their impact on the exposure of hands of nuclear medicine facility staff
Purpose: The increasing use of peptide receptor radionuclide therapy (PRRT) with 177 Lu-DOTATATE increases the need to assess occupational radiation exposure of nuclear medicine staff, particularly to the hands. This study aimed to evaluate and compare fingertip exposure associated with three administration methods: gravitational infusion, infusion pump, and manual injection. Materials and Methods: Dosimetric measurements were performed in two nuclear medicine centres using LiF:Mg,Cu,P thermoluminescent detectors placed on the fingertips and at the base of the middle finger of both hands of staff involved in radiopharmaceutical preparation and administration. Measurements were collected for physicists, radiopharmacists, nurses, and physicians. A total of 126 measurements were collected in four measurement sessions. The personal dose equivalent H p (0.07) was determined, normalised to administered activity (µSv/GBq), and analysed separately for preparation and administration procedures. Results: Manual administration resulted in the highest fingertip exposure, with maximum normalized H p (0.07) values of 26.95 µSv/GBq during preparation and 40.23 µSv/GBq during administration. Infusion pump administration showed intermediate exposure levels, while gravitational infusion yielded the lowest values, often close to the minimum detectable dose. Dominant hand fingertips, particularly the thumb and index finger, were most exposed. Estimated annual doses remained well below the skin dose limit. Conclusions: The administration technique significantly influences occupational hand exposure during 177 Lu- DOTATATE procedures. Manual administration leads to the highest doses, whereas gravitational and infusion pump methods substantially reduce staff exposure.
- 1 September 2026
- Published by Walter de Gruyter GmbH in Polish Journal of Medical Physics And Engineering
- Vol. 32 (3) , 138-145
Open AccessAnalysis of 177 Lu-DOTATATE injection methods and their impact on the exposure of hands of nuclear medicine facility staff
Purpose: The increasing use of peptide receptor radionuclide therapy (PRRT) with 177 Lu-DOTATATE increases the need to assess occupational radiation exposure of nuclear medicine staff, particularly to the hands. This study aimed to evaluate and compare fingertip exposure associated with three administration methods: gravitational infusion, infusion pump, and manual injection. Materials and Methods: Dosimetric measurements were performed in two nuclear medicine centres using LiF:Mg,Cu,P thermoluminescent detectors placed on the fingertips and at the base of the middle finger of both hands of staff involved in radiopharmaceutical preparation and administration. Measurements were collected for physicists, radiopharmacists, nurses, and physicians. A total of 126 measurements were collected in four measurement sessions. The personal dose equivalent H p (0.07) was determined, normalised to administered activity (µSv/GBq), and analysed separately for preparation and administration procedures. Results: Manual administration resulted in the highest fingertip exposure, with maximum normalized H p (0.07) values of 26.95 µSv/GBq during preparation and 40.23 µSv/GBq during administration. Infusion pump administration showed intermediate exposure levels, while gravitational infusion yielded the lowest values, often close to the minimum detectable dose. Dominant hand fingertips, particularly the thumb and index finger, were most exposed. Estimated annual doses remained well below the skin dose limit. Conclusions: The administration technique significantly influences occupational hand exposure during 177 Lu- DOTATATE procedures. Manual administration leads to the highest doses, whereas gravitational and infusion pump methods substantially reduce staff exposure.
- Open Access
- 4 September 2023
- Published by Elsevier in Radiation Physics and Chemistry
- Vol. 214
Risk factors for eye lens opacity in nuclear medicine workers – An overview
- 4 September 2023
- Published by Elsevier in Radiation Physics and Chemistry
- Vol. 214
Open AccessRisk factors for eye lens opacity in nuclear medicine workers – An overview
- 1 August 2020
- Published by Elsevier in Zeitschrift für Medizinische Physik
- Vol. 30 (3) , 222-226
Calibration of the LiF - thermoluminescent detectors used for personal dose equivalent Hp(3) assessment
- 1 August 2020
- Published by Elsevier in Zeitschrift für Medizinische Physik
- Vol. 30 (3) , 222-226
Calibration of the LiF - thermoluminescent detectors used for personal dose equivalent Hp(3) assessment
- Open Access
- 22 February 2020
- Published by Springer Nature in Radiation and Environmental Biophysics
- Vol. 59 (2) , 331-336
The photo-transferred thermoluminescence phenomenon in case of emergency dose assessment
A major disadvantage of dose reconstruction by means of thermoluminescence (TL) is the fact that during readout of any TL material exposed to ionizing radiation (i.e., during measuring the glow curve), the radiation-induced signal gets lost. Application of the photo-transferred thermoluminescence phenomenon (PTTL) may offer a solution to this problem. In PTTL, the residual signal that is not destroyed by conventional TL readout (because it comes from deeper electron traps) can be readout through simultaneous stimulation by UV light and heating, allowing to obtain information about the absorbed dose in a second run. The present paper describes the application of PTTL for emergency dose assessment. For this, MTS-N thermoluminescent detectors (LiF: Mg, Ti) were exposed using a high-energy Clinac 2300 medical linear accelerator to doses of 100 mGy, 300 mGy, 500 mGy, 700 mGy and 1000 mGy. Irradiation with UV radiation allowed the determination of the optimal heating time of 3 h, while the optimal temperature was identified to be 70 °C. The results obtained demonstrated the usefulness of the PTTL method for emergency dose assessment. The efficiency of the PTTL method was determined as 19%. Finally it was found that the detector background after UV exposure should not be underestimated during routine dose measurements.
- 22 February 2020
- Published by Springer Nature in Radiation and Environmental Biophysics
- Vol. 59 (2) , 331-336
Open AccessThe photo-transferred thermoluminescence phenomenon in case of emergency dose assessment
A major disadvantage of dose reconstruction by means of thermoluminescence (TL) is the fact that during readout of any TL material exposed to ionizing radiation (i.e., during measuring the glow curve), the radiation-induced signal gets lost. Application of the photo-transferred thermoluminescence phenomenon (PTTL) may offer a solution to this problem. In PTTL, the residual signal that is not destroyed by conventional TL readout (because it comes from deeper electron traps) can be readout through simultaneous stimulation by UV light and heating, allowing to obtain information about the absorbed dose in a second run. The present paper describes the application of PTTL for emergency dose assessment. For this, MTS-N thermoluminescent detectors (LiF: Mg, Ti) were exposed using a high-energy Clinac 2300 medical linear accelerator to doses of 100 mGy, 300 mGy, 500 mGy, 700 mGy and 1000 mGy. Irradiation with UV radiation allowed the determination of the optimal heating time of 3 h, while the optimal temperature was identified to be 70 °C. The results obtained demonstrated the usefulness of the PTTL method for emergency dose assessment. The efficiency of the PTTL method was determined as 19%. Finally it was found that the detector background after UV exposure should not be underestimated during routine dose measurements.
- Open Access
- 1 January 2020
- Published by Nofer Institute of Occupational Medicine in Medycyna Pracy
- Vol. 71 (3) , 398
CALIBRATION OF THERMOLUMINESCENT DETECTORS IN HP(0.07) UNITS BY USING AN X-RAY TUBE AND A 137CS SOURCE (vol 70, pg 669, 2019)
The original version of the article can be found at http://medpr.imp.lodz.pl/Calibration-of-thermoluminescent-detectors-in-H-p-0-07-units-by-using-an-X-ray-tube,109931,0,2.html.
- 1 January 2020
- Published by Nofer Institute of Occupational Medicine in Medycyna Pracy
- Vol. 71 (3) , 398
Open AccessCALIBRATION OF THERMOLUMINESCENT DETECTORS IN HP(0.07) UNITS BY USING AN X-RAY TUBE AND A 137CS SOURCE (vol 70, pg 669, 2019)
The original version of the article can be found at http://medpr.imp.lodz.pl/Calibration-of-thermoluminescent-detectors-in-H-p-0-07-units-by-using-an-X-ray-tube,109931,0,2.html.
- 1 January 2020
- Published by Sievert Association in Rap 2019 Conference Proceedings
A NEED FOR EYE LENS DOSIMETRY IN NUCLEAR MEDICINE
- 1 January 2020
- Published by Sievert Association in Rap 2019 Conference Proceedings
A NEED FOR EYE LENS DOSIMETRY IN NUCLEAR MEDICINE
- Open Access
- 3 December 2019
- Published by Nofer Institute of Occupational Medicine in Medycyna Pracy
- Vol. 70 (6) , 669-673
Calibration of thermoluminescent detectors in Hp(0.07) units by using an X-ray tube and a 137Cs source
Background: The method of measuring doses based on the thermoluminescence phenomenon is not an absolute method. For this reason, to obtain correct results, it is necessary to calibrate detectors in the known radiation field. This paper presents a method for calibrating thermoluminescent...
- 3 December 2019
- Published by Nofer Institute of Occupational Medicine in Medycyna Pracy
- Vol. 70 (6) , 669-673
Open AccessCalibration of thermoluminescent detectors in Hp(0.07) units by using an X-ray tube and a 137Cs source
Background: The method of measuring doses based on the thermoluminescence phenomenon is not an absolute method. For this reason, to obtain correct results, it is necessary to calibrate detectors in the known radiation field. This paper presents a method for calibrating thermoluminescent...
- 1 December 2018
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 182 (4) , 464-471
THYROID EXPOSURE DURING 18F-FDG PRODUCTION PROCEDURES
The production of radiopharmaceuticals for the needs of positron emission tomography (PET), in particular F-18-FDG, is a multi-step process performed most often by physicists and chemists. The monitoring of occupational exposure of staff employed in radiopharmaceutical production centres includes the measurement of the Hp(10) and Hp(0.07) values. Occupational exposure to ionising radiation means that the thyroid may be, among others, affected by the radiation field. This work analyses the exposure of the thyroid gland of employees of centres that produce the isotopes for PET, in particular fluorine-18. The analysis take into account the employment structure and work system of the discussed centres. Measurements were carried out by using high-sensitivity thermoluminescence detectors (MCP-N). The measurements covered 17 employees. Our results show that the estimated maximum annual thyroid gland exposure will not exceed 30 mSv.
- 1 December 2018
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 182 (4) , 464-471
THYROID EXPOSURE DURING 18F-FDG PRODUCTION PROCEDURES
The production of radiopharmaceuticals for the needs of positron emission tomography (PET), in particular F-18-FDG, is a multi-step process performed most often by physicists and chemists. The monitoring of occupational exposure of staff employed in radiopharmaceutical production centres includes the measurement of the Hp(10) and Hp(0.07) values. Occupational exposure to ionising radiation means that the thyroid may be, among others, affected by the radiation field. This work analyses the exposure of the thyroid gland of employees of centres that produce the isotopes for PET, in particular fluorine-18. The analysis take into account the employment structure and work system of the discussed centres. Measurements were carried out by using high-sensitivity thermoluminescence detectors (MCP-N). The measurements covered 17 employees. Our results show that the estimated maximum annual thyroid gland exposure will not exceed 30 mSv.
- 29 November 2018
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 184 (2) , 224-229
THE STRUCTURE OF Hp(0.07) VALUES OBTAINED BY THE NUCLEAR MEDICINE PERSONNEL DURING 18F-FDG PRODUCTION AND INJECTION
The production of 18F-FDG is a multi-stage process, which includes not only obtaining the marker and labelling the radiopharmaceutical but also carrying out the quality control of the obtained compound. The staff can be exposed to ionizing radiation at any stage of production. This article presents the results of hands exposure of staff members employed in a facility, where 18F-FDG is produced and injected into patients. High-sensitivity thermoluminescent detectors (MCP-N) were used for measurements. The measurements were conducted with regard to the occupational structure the employees and the performed procedures. The obtained results showed that the highest risk of radiation exposure for personnel was associated with the quality control of the radiopharmaceutical. The daily doses registered by MCP-N detectors on fingertips reached 4.5 mSv, which may result in exceeding the annual radiation limit of 500 mSv.
- 29 November 2018
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 184 (2) , 224-229
THE STRUCTURE OF Hp(0.07) VALUES OBTAINED BY THE NUCLEAR MEDICINE PERSONNEL DURING 18F-FDG PRODUCTION AND INJECTION
The production of 18F-FDG is a multi-stage process, which includes not only obtaining the marker and labelling the radiopharmaceutical but also carrying out the quality control of the obtained compound. The staff can be exposed to ionizing radiation at any stage of production. This article presents the results of hands exposure of staff members employed in a facility, where 18F-FDG is produced and injected into patients. High-sensitivity thermoluminescent detectors (MCP-N) were used for measurements. The measurements were conducted with regard to the occupational structure the employees and the performed procedures. The obtained results showed that the highest risk of radiation exposure for personnel was associated with the quality control of the radiopharmaceutical. The daily doses registered by MCP-N detectors on fingertips reached 4.5 mSv, which may result in exceeding the annual radiation limit of 500 mSv.
- 23 November 2018
- Published by IOP Publishing in Journal of Radiological Protection
- Vol. 38 (4) , 1512-1523
68 Ga-DOTA-TATE—a source of eye lens exposure for nuclear medicine department workers
Introduction. Obtaining 68 Ga-DOTA-TATE (a radioconjugate consisting of the somatostatin analogue tyrosine-3-octreotate (Tyr3-octreotate or TATE) labelled with the positron emission tomography tracer gallium 68 Ga via the macrocyclic chelating agent dodecanetetraacetic acid (DOTA)) is a complex process and, as with any radiopharmaceutical whose basis is a short-lived radionuclide generator, it is based on a sequence of procedures beginning from the 68 Ge/ 68 Ga generator elution, labelling ligands with a radioisotope, dispensing doses of 68 Ga-DOTA-TATE for patients and finally injection of the preparation to patients. The complexity of this process may contribute to an increased exposure of eye lenses of the staff who perform the above-mentioned procedures, which is especially important at a time when the dose limit on the lens of the eye is being reduced from 150 to 20 mSv yr –1 . Objective. The work presents the exposure of eye lenses of the personnel of a nuclear medicine department who prepare and inject 68 Ga-DOTA-TATE. Materials and methods. Radiochemists and nurses were monitored by dosimetry measurements with thermoluminescent detectors (TLDs). Results. The values of H p (3)/A—normalised personal eye dose equivalent recorded in the group of radiochemists during the procedure of dispensing the doses of 68 Ga-DOTA-TATE for patients exceeded the value of 274 μ Sv/GBq. Conclusions. The estimated annual H p (3) values may exceed 20 mSv, which is particularly important due to the fact that procedures using the 68 Ga radioactivity are only a small part of the daily professional activity of the staff, resulting from the performance of other procedures that require the use of other radioisotopes.
- 23 November 2018
- Published by IOP Publishing in Journal of Radiological Protection
- Vol. 38 (4) , 1512-1523
68 Ga-DOTA-TATE—a source of eye lens exposure for nuclear medicine department workers
Introduction. Obtaining 68 Ga-DOTA-TATE (a radioconjugate consisting of the somatostatin analogue tyrosine-3-octreotate (Tyr3-octreotate or TATE) labelled with the positron emission tomography tracer gallium 68 Ga via the macrocyclic chelating agent dodecanetetraacetic acid (DOTA)) is a complex process and, as with any radiopharmaceutical whose basis is a short-lived radionuclide generator, it is based on a sequence of procedures beginning from the 68 Ge/ 68 Ga generator elution, labelling ligands with a radioisotope, dispensing doses of 68 Ga-DOTA-TATE for patients and finally injection of the preparation to patients. The complexity of this process may contribute to an increased exposure of eye lenses of the staff who perform the above-mentioned procedures, which is especially important at a time when the dose limit on the lens of the eye is being reduced from 150 to 20 mSv yr –1 . Objective. The work presents the exposure of eye lenses of the personnel of a nuclear medicine department who prepare and inject 68 Ga-DOTA-TATE. Materials and methods. Radiochemists and nurses were monitored by dosimetry measurements with thermoluminescent detectors (TLDs). Results. The values of H p (3)/A—normalised personal eye dose equivalent recorded in the group of radiochemists during the procedure of dispensing the doses of 68 Ga-DOTA-TATE for patients exceeded the value of 274 μ Sv/GBq. Conclusions. The estimated annual H p (3) values may exceed 20 mSv, which is particularly important due to the fact that procedures using the 68 Ga radioactivity are only a small part of the daily professional activity of the staff, resulting from the performance of other procedures that require the use of other radioisotopes.