Optimization of beam quality for photon-counting spectral computed tomography in head imaging: simulation study
- 1 October 2015
- journal article
- Published by SPIE-Intl Soc Optical Eng in Journal of Medical Imaging
- Vol. 2 (4) , 043504
Abstract
Head computed tomography (CT) plays an important role in the comprehensive evaluation of acute stroke. Photon-counting spectral detectors, as promising candidates for use in the next generation of x-ray CT systems, allow for assigning more weight to low-energy x-rays that generally contain more contrast information. Most importantly, the spectral information can be utilized to decompose the original set of energy-selective images into several basis function images that are inherently free of beam-hardening artifacts, a potential advantage for further improving the diagnosis accuracy. We are developing a photon-counting spectral detector for CT applications. The purpose of this work is to determine the optimal beam quality for material decomposition in two head imaging cases: nonenhanced imaging and K-edge imaging. A cylindrical brain tissue of 16-cm diameter, coated by a 6-mm-thick bone layer and 2-mm-thick skin layer, was used as a head phantom. The imaging target was a 5-mm-thick blood vessel centered in the head phantom. In K-edge imaging, two contrast agents, iodine and gadolinium, with the same concentration () were studied. Three parameters that affect beam quality were evaluated: kVp settings (50 to 130 kVp), filter materials ( to 83), and filter thicknesses [0 to 2 half-value layer (HVL)]. The image qualities resulting from the varying x-ray beams were compared in terms of two figures of merit (FOMs): squared signal-difference-to-noise ratio normalized by brain dose () and that normalized by skin dose (). For nonenhanced imaging, the results show that the use of the 120-kVp spectrum filtered by 2 HVL copper () provides the best performance in both FOMs. When iodine is used in K-edge imaging, the optimal filter is 2 HVL iodine () and the optimal kVps are 60 kVp in terms of and 75 kVp in terms of . A tradeoff of 65 kVp was proposed to lower the potential risk of skin injuries if a relatively long exposure time is necessarily performed in the iodinated imaging. In the case of gadolinium imaging, both SD and BD can be minimized at 120 kVp filtered with 2 HVL thulium (). The results also indicate that with the same concentration and their respective optimal spectrum, the values of and in gadolinium imaging are, respectively, around 3 and 10 times larger than those in iodine imaging. However, since gadolinium is used in much lower concentrations than iodine in the clinic, iodine may be a preferable candidate for K-edge imaging.
Keywords
This publication has 42 references indexed in Scilit:
- Toward quantifying the composition of soft tissues by spectral CT with Medipix3Medical Physics, 2012
- Performance evaluation of a sub-millimetre spectrally resolved CT system on high- and low-frequency imaging tasks: a simulationPhysics in Medicine & Biology, 2012
- Projection x-ray imaging with photon energy weighting: experimental evaluation with a prototype detectorPhysics in Medicine & Biology, 2009
- Cramér–Rao lower bound of basis image noise in multiple-energy x-ray imagingPhysics in Medicine & Biology, 2009
- Experimental feasibility of multi-energy photon-counting K-edge imaging in pre-clinical computed tomographyPhysics in Medicine & Biology, 2008
- Mechanical Thrombectomy for Acute Ischemic StrokeStroke, 2008
- Beam hardening artefacts in computed tomography with photon counting, charge integrating and energy weighting detectors: a simulation studyPhysics in Medicine & Biology, 2005
- A framework for optimising the radiographic technique in digital X-ray imagingRadiation Protection Dosimetry, 2005
- SNR and noise measurements for medical imaging: I. A practical approach based on statistical decision theoryPhysics in Medicine & Biology, 1993
- Energy-selective reconstructions in X-ray computerised tomographyPhysics in Medicine & Biology, 1976