Aseptic midterm survival rates between different cemented tibial stem designs in hinged total knee arthroplasty: a 6-year evaluation from the German Arthroplasty Registry
Open Access
- 16 April 2024
- journal article
- research article
- Published by Springer Nature in Archives of orthopaedic and trauma surgery
- Vol. 144 (5) , 2283-2295
Abstract
Introduction: The rate of revision TKA and thus the use of hinged implants (HI) steadily rises. Aseptic loosening lies on the top of the failure patterns. However, no evidence exists until now based on national scale high-caseloads that analyzes the impact of cemented HI stem-design on aseptic survival rates. Methods: Data on aseptic HI-revisions with full-cemented tibia-stems were conducted from the German Arthroplasty Registry. Cases were divided in primary HI (PHI) and HI used in revision operations (RHI). Endpoint was a new revision following either a PHI or an RHI. The impact of stem conicity (conical vs. cylindrical), diameter (≤ 13 mm vs. > 13 mm), length (≤ 90 mm vs. > 90 mm) and offset on the 6-Year-Cumulative-Aseptic-Revision-Rate (6Y-CARR) was estimated via Kaplan–Meier curve and compared between groups via Log-Rank-Tests. Results: 3953 PHI and 2032 RHI fulfilled inclusion-criteria. Stem conicity had no impact on 6Y-CARR (p = 0.08 and p = 0.8). Diameter > 13 mm hat an impact on PHI (p = 0.05) with lower 6Y-CARR but not on RHI (p = 0.2). Length > 90 mm showed significantly worst 6Y-CARR in PHI (p = 0.0001) but not in RHI (p = 0.3). Offset-stems showed significantly better 6Y-CARR in PHI (p = 0.04), but not in RHI (p = 0.7). Conclusion: There was no significant impact of the cemented tibia-stem conicity on 6Y-CARR, neither in PHI nor in RHI. The effect of length, diameter and offset on the 6Y-CARR observed in the PHI, was not detectable in the more complex RHI-cases reflecting its limited clinical relevance by itself in more multifactorial backgrounds. Therefore, results must be interpreted with caution due to considerable system-effects and different utilization-scenarios.Keywords
Funding Information
- Universitätsklinikum Jena
This publication has 75 references indexed in Scilit:
- Impact of stem profile on the revisability and the need for osteotomy in well-fixed cemented revision total knee arthroplasty implantsArchives of orthopaedic and trauma surgery, 2022
- A novel radiological classification system of the distal femurArchives of orthopaedic and trauma surgery, 2021
- Risk factors for aseptic loosening in complex revision total knee arthroplasty using rotating hinge implantsInternational Orthopaedics, 2020
- The projected volume of primary and revision total knee arthroplasty will place an immense burden on future health care systems over the next 30 yearsKnee Surgery, Sports Traumatology, Arthroscopy, 2020
- Sagittal profile has a significant impact on the explantability of well-fixed cemented stems in revision knee arthroplasty: a biomechanical comparison study of five established knee implant modelsArchives of orthopaedic and trauma surgery, 2019
- Cemented conical stems can be removed more easily than cylindrical stems, regardless of cone angle in revision knee arthroplastyArchives of orthopaedic and trauma surgery, 2018
- The survivorship of the link endo-rotational hinge total knee arthroplasty: 5–12-year follow-up of 100 patientsArchives of orthopaedic and trauma surgery, 2018
- Fixation techniques and stem dimensions in hinged total knee arthroplasty: a finite element studyArchives of orthopaedic and trauma surgery, 2016
- Implant survival and outcome after rotating-hinge total knee revision arthroplasty: a minimum 6-year follow-upArchives of orthopaedic and trauma surgery, 2011
- Failure following revision total knee arthroplasty: infection is the major causeInternational Orthopaedics, 2010