$^{88}$Sr$^{+}$ optical clock with $7.9\times 10^{-19}$ systematic uncertainty and measurement of its absolute frequency with $9.8\times 10^{-17}$ uncertainty
Authors:
- T. LindvallTLT. Lindvall
- T. FordellTFT. Fordell
- K. J. HanhijärviKHK. J. Hanhijärvi
- M. DoležalMDM. Doležal
- J. RahmJRJ. Rahm
- S. WeyersSWS. Weyers
- A. E. WallinAWA. E. Wallin
Preprint
Abstract
We report on a $^{88}$Sr$^{+}$ single-ion optical clock with an estimated fractional systematic uncertainty of $7.9\times 10^{-19}$. The low uncertainty is enabled by small rf losses, a thorough evaluation of the blackbody-radiation temperature, and our recent measurement of the differential polarizability. A detailed uncertainty evaluation is presented. We also report on two absolute frequency measurements: one against a remote cesium fountain clock and one against International Atomic Time (TAI). The former lasted 12 days and resulted in a frequency value of 444779044095485.49(15) Hz. The latter spanned ten months with monthly optical-clock uptimes between 68% and 99% and yielded a frequency value of 444779044095485.373(44) Hz. With a fractional uncertainty of $9.8\times 10^{-17}$, it is, to our knowledge, the most accurate optical frequency measurement reported to date. Both frequency values are in agreement with other recent measurements, providing further evidence that the 2021 CIPM recommended frequency value is too high by 1.6 times its uncertainty.
Keywords
All Related Versions
This publication has 61 references indexed in Scilit:
- Frequency ratio measurements at 18-digit accuracy using an optical clock networkNature, 2021
- Test of general relativity by a pair of transportable optical lattice clocksNature Photonics, 2020
- NKG2016LU: a new land uplift model for Fennoscandia and the Baltic RegionJournal of Geodesy, 2019
- Optical clock comparison for Lorentz symmetry testingNature, 2019
- Atomic clock performance enabling geodesy below the centimetre levelNature, 2018
- Geodesy and metrology with a transportable optical clockNature Physics, 2018
- Geodetic methods to determine the relativistic redshift at the level of 10−18 in the context of international timescales: a review and practical resultsJournal of Geodesy, 2017
- Budget of Uncertainties in the Cesium Frequency Frame of Fountain TypeMeasurement Techniques, 2017
- Absolute optical frequency measurement of saturated absorption lines in Rb near 422 nmApplied Physics B, 2007
- Quantum dynamics of cold trapped ions with application to quantum computationApplied Physics B, 1998