Validation of a Denoising Method Using Deep Learning–Based Reconstruction to Quantify Multiple Sclerosis Lesion Load on Fast FLAIR Imaging
- 28 July 2022
- journal article
- research article
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 43 (8) , 1099-1106
Abstract
BACKGROUND AND PURPOSE: Accurate quantification of WM lesion load is essential for the care of patients with multiple sclerosis. We tested whether the combination of accelerated 3D-FLAIR and denoising using deep learning–based reconstruction could provide a relevant strategy while shortening the imaging examination. MATERIALS AND METHODS: Twenty-eight patients with multiple sclerosis were prospectively examined using 4 implementations of 3D-FLAIR with decreasing scan times (4 minutes 54 seconds, 2 minutes 35 seconds, 1 minute 40 seconds, and 1 minute 15 seconds). Each FLAIR sequence was reconstructed without and with denoising using deep learning–based reconstruction, resulting in 8 FLAIR sequences per patient. Image quality was assessed with the Likert scale, apparent SNR, and contrast-to-noise ratio. Manual and automatic lesion segmentations, performed randomly and blindly, were quantitatively evaluated against ground truth using the absolute volume difference, true-positive rate, positive predictive value, Dice similarity coefficient, Hausdorff distance, and F1 score based on the lesion count. The Wilcoxon signed-rank test and 2-way ANOVA were performed. RESULTS: Both image-quality evaluation and the various metrics showed deterioration when the FLAIR scan time was accelerated. However, denoising using deep learning–based reconstruction significantly improved subjective image quality and quantitative performance metrics, particularly for manual segmentation. Overall, denoising using deep learning–based reconstruction helped to recover contours closer to those from the criterion standard and to capture individual lesions otherwise overlooked. The Dice similarity coefficient was equivalent between the 2-minutes-35-seconds-long FLAIR with denoising using deep learning–based reconstruction and the 4-minutes-54-seconds-long reference FLAIR sequence. CONCLUSIONS: Denoising using deep learning–based reconstruction helps to recognize multiple sclerosis lesions buried in the noise of accelerated FLAIR acquisitions, a possibly useful strategy to efficiently shorten the scan time in clinical practice.Keywords
Funding Information
- ARSEP
- Agence Nationale de la Recherche (ANR-10-LABX-57)
- Roche Laboratory
This publication has 36 references indexed in Scilit:
- Optimizing treatment success in multiple sclerosisJournal of Neurology, 2015
- Revised Recommendations of the Consortium of MS Centers Task Force for a Standardized MRI Protocol and Clinical Guidelines for the Diagnosis and Follow-Up of Multiple SclerosisAmerican Journal of Neuroradiology, 2015
- Simultaneous multislice (SMS) imaging techniquesMagnetic Resonance in Medicine, 2015
- A survey on the magnetic resonance image denoising methodsBiomedical Signal Processing and Control, 2014
- Parallel MR imagingJournal of Magnetic Resonance Imaging, 2012
- Evolution of the blood–brain barrier in newly forming multiple sclerosis lesionsAnnals of Neurology, 2011
- The aligned rank transform for nonparametric factorial analyses using only anova procedures2011
- Multiple sclerosisThe Lancet, 2008
- Isotropic 3D fast FLAIR imaging of the brain in multiple sclerosis patients: initial experienceEuropean Radiology, 2002
- Halving MR imaging time by conjugation: demonstration at 3.5 kG.Radiology, 1986