Hikaru Fukutomi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Hikaru Fukutomi has a total of 95 co-authors. Here are the top co-authors by number of shared publications:
- Takayuki Yamamoto
Department of Diagnostic Imaging and Nuclear Medicine, Graduate School of Medicine, Kyoto University, Kyoto, Japan
5 shared publications - Thomas Tourdias
Centre Hospitalier Universitaire (CHU) de Bordeaux, Neuroimagerie Diagnostique et Thérapeutique , 33076 Bordeaux
4 shared publications - Vincent Dousset
From the Institut de Bio-imagerie IBIO (F.M., T.T., V.D.), Université Bordeaux, Bordeaux, France
4 shared publications Kaori Togashi
Department of Diagnostic Imaging and Nuclear Medicine, Kyoto University Graduate School of Medicine, Kawaramachi 54, Shogoin, Sakyo-ku, Kyoto city, 606-8507, Japan
3 shared publications- Bei Zhang
Canon Medical Systems Europe, Bovenkerkerweg 59, 1185XB Amstelveen, Netherlands
2 shared publications - Hui Zhang
Centre for Medical Image Computing and Department of Computer Science, University College London, London, UK
2 shared publications
Latest Publications
- 11 December 2025
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 47 (1) , 225-233
Enhanced Spinal Cord Lesion Detection in MS Using White-Matter-Nulled 3D MPRAGE with Deep Learning Reconstruction
BACKGROUND AND PURPOSE: Spinal cord (SC) lesions are critical in MS diagnosis and progression, yet their detection remains challenging. Conventional sequences such as 2D T2-weighted FSE and STIR have suboptimal sensitivity, both in the cervical and thoracic spine. This study evaluated the diagnostic performance of a new imaging technique for SC lesion detection, the 3D white-matter-nulled (WMn) MPRAGE sequence, compared with conventional MRI sequences. MATERIALS AND METHODS: Thirty-eight patients with MS or clinically isolated syndrome were prospectively evaluated with 3T SC MRI, acquiring 2D T2-weighted FSE, 2D STIR, 3D MPRAGE, and 3D WMn. A deep learning denoising method was applied to 3D WMn to compensate the inherent low signal. Four blinded neuroradiologists independently assessed lesion count, confidence in lesion detection, and image quality (eg, artifacts). Contrast-to-noise ratio (CNR) was also computed for all lesions detected on all sequences. Statistical comparisons were performed across sequences. RESULTS: In the cervicothoracic spine, the 3D WMn sequence detected significantly more lesions than 2D T2-weighted FSE (+62%; P < .001), STIR (+47%; P < .05), and 3D MPRAGE (+50%; P < .01). In the thoracolumbar spine, the 3D WMn sequence detected significantly more lesions than 2D T2-weighted FSE (+53%, P < .05). The 3D WMn sequence demonstrated a higher CNR and improved lesion conspicuity while exhibiting fewer artifacts than STIR. These advantages contributed to greater rater confidence in lesion detection by using the 3D WMn sequence, with over 75% of strong confidence reported by the 2 most experienced raters, along with the highest interreader agreement. CONCLUSIONS: The 3D WMn sequence associated with deep learning–based denoising significantly improves SC lesion detection, outperforming all conventional sequences. Three-dimensional WMn represents, then, a promising alternative for SC imaging in MS.
- 11 December 2025
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 47 (1) , 225-233
Enhanced Spinal Cord Lesion Detection in MS Using White-Matter-Nulled 3D MPRAGE with Deep Learning Reconstruction
BACKGROUND AND PURPOSE: Spinal cord (SC) lesions are critical in MS diagnosis and progression, yet their detection remains challenging. Conventional sequences such as 2D T2-weighted FSE and STIR have suboptimal sensitivity, both in the cervical and thoracic spine. This study evaluated the diagnostic performance of a new imaging technique for SC lesion detection, the 3D white-matter-nulled (WMn) MPRAGE sequence, compared with conventional MRI sequences. MATERIALS AND METHODS: Thirty-eight patients with MS or clinically isolated syndrome were prospectively evaluated with 3T SC MRI, acquiring 2D T2-weighted FSE, 2D STIR, 3D MPRAGE, and 3D WMn. A deep learning denoising method was applied to 3D WMn to compensate the inherent low signal. Four blinded neuroradiologists independently assessed lesion count, confidence in lesion detection, and image quality (eg, artifacts). Contrast-to-noise ratio (CNR) was also computed for all lesions detected on all sequences. Statistical comparisons were performed across sequences. RESULTS: In the cervicothoracic spine, the 3D WMn sequence detected significantly more lesions than 2D T2-weighted FSE (+62%; P < .001), STIR (+47%; P < .05), and 3D MPRAGE (+50%; P < .01). In the thoracolumbar spine, the 3D WMn sequence detected significantly more lesions than 2D T2-weighted FSE (+53%, P < .05). The 3D WMn sequence demonstrated a higher CNR and improved lesion conspicuity while exhibiting fewer artifacts than STIR. These advantages contributed to greater rater confidence in lesion detection by using the 3D WMn sequence, with over 75% of strong confidence reported by the 2 most experienced raters, along with the highest interreader agreement. CONCLUSIONS: The 3D WMn sequence associated with deep learning–based denoising significantly improves SC lesion detection, outperforming all conventional sequences. Three-dimensional WMn represents, then, a promising alternative for SC imaging in MS.
- 1 February 2023
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 306 (2) , e220080
Location-weighted versus Volume-weighted Mismatch at MRI for Response to Mechanical Thrombectomy in Acute Stroke
A location-weighted mismatch and infarction core model based on diffusion and perfusion MRI improved the identification of patients with acute stroke who would benefit from mechanical thrombectomy. Background A target mismatch profile can identify good clinical response to recanalization after acute ischemic stroke, but does not consider region specificities. Purpose To test whether location-...
- 1 February 2023
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 306 (2) , e220080
Location-weighted versus Volume-weighted Mismatch at MRI for Response to Mechanical Thrombectomy in Acute Stroke
A location-weighted mismatch and infarction core model based on diffusion and perfusion MRI improved the identification of patients with acute stroke who would benefit from mechanical thrombectomy. Background A target mismatch profile can identify good clinical response to recanalization after acute ischemic stroke, but does not consider region specificities. Purpose To test whether location-...
- 28 July 2022
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 43 (8) , 1099-1106
Validation of a Denoising Method Using Deep Learning–Based Reconstruction to Quantify Multiple Sclerosis Lesion Load on Fast FLAIR Imaging
BACKGROUND AND PURPOSE: Accurate quantification of WM lesion load is essential for the care of patients with multiple sclerosis. We tested whether the combination of accelerated 3D-FLAIR and denoising using deep learning–based reconstruction could provide a relevant strategy while shortening the imaging examination. MATERIALS AND METHODS: Twenty-eight patients with multiple sclerosis were prospectively examined using 4 implementations of 3D-FLAIR with decreasing scan times (4 minutes 54 seconds, 2 minutes 35 seconds, 1 minute 40 seconds, and 1 minute 15 seconds). Each FLAIR sequence was reconstructed without and with denoising using deep learning–based reconstruction, resulting in 8 FLAIR sequences per patient. Image quality was assessed with the Likert scale, apparent SNR, and contrast-to-noise ratio. Manual and automatic lesion segmentations, performed randomly and blindly, were quantitatively evaluated against ground truth using the absolute volume difference, true-positive rate, positive predictive value, Dice similarity coefficient, Hausdorff distance, and F1 score based on the lesion count. The Wilcoxon signed-rank test and 2-way ANOVA were performed. RESULTS: Both image-quality evaluation and the various metrics showed deterioration when the FLAIR scan time was accelerated. However, denoising using deep learning–based reconstruction significantly improved subjective image quality and quantitative performance metrics, particularly for manual segmentation. Overall, denoising using deep learning–based reconstruction helped to recover contours closer to those from the criterion standard and to capture individual lesions otherwise overlooked. The Dice similarity coefficient was equivalent between the 2-minutes-35-seconds-long FLAIR with denoising using deep learning–based reconstruction and the 4-minutes-54-seconds-long reference FLAIR sequence. CONCLUSIONS: Denoising using deep learning–based reconstruction helps to recognize multiple sclerosis lesions buried in the noise of accelerated FLAIR acquisitions, a possibly useful strategy to efficiently shorten the scan time in clinical practice.
- 28 July 2022
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 43 (8) , 1099-1106
Validation of a Denoising Method Using Deep Learning–Based Reconstruction to Quantify Multiple Sclerosis Lesion Load on Fast FLAIR Imaging
BACKGROUND AND PURPOSE: Accurate quantification of WM lesion load is essential for the care of patients with multiple sclerosis. We tested whether the combination of accelerated 3D-FLAIR and denoising using deep learning–based reconstruction could provide a relevant strategy while shortening the imaging examination. MATERIALS AND METHODS: Twenty-eight patients with multiple sclerosis were prospectively examined using 4 implementations of 3D-FLAIR with decreasing scan times (4 minutes 54 seconds, 2 minutes 35 seconds, 1 minute 40 seconds, and 1 minute 15 seconds). Each FLAIR sequence was reconstructed without and with denoising using deep learning–based reconstruction, resulting in 8 FLAIR sequences per patient. Image quality was assessed with the Likert scale, apparent SNR, and contrast-to-noise ratio. Manual and automatic lesion segmentations, performed randomly and blindly, were quantitatively evaluated against ground truth using the absolute volume difference, true-positive rate, positive predictive value, Dice similarity coefficient, Hausdorff distance, and F1 score based on the lesion count. The Wilcoxon signed-rank test and 2-way ANOVA were performed. RESULTS: Both image-quality evaluation and the various metrics showed deterioration when the FLAIR scan time was accelerated. However, denoising using deep learning–based reconstruction significantly improved subjective image quality and quantitative performance metrics, particularly for manual segmentation. Overall, denoising using deep learning–based reconstruction helped to recover contours closer to those from the criterion standard and to capture individual lesions otherwise overlooked. The Dice similarity coefficient was equivalent between the 2-minutes-35-seconds-long FLAIR with denoising using deep learning–based reconstruction and the 4-minutes-54-seconds-long reference FLAIR sequence. CONCLUSIONS: Denoising using deep learning–based reconstruction helps to recognize multiple sclerosis lesions buried in the noise of accelerated FLAIR acquisitions, a possibly useful strategy to efficiently shorten the scan time in clinical practice.
- Open Access
- 22 August 2019
- Published by Springer Nature in Scientific Reports
- Vol. 9 (1) , 1-12
Diffusion Tensor Model links to Neurite Orientation Dispersion and Density Imaging at high b-value in Cerebral Cortical Gray Matter
Diffusion tensor imaging (DTI) and neurite orientation dispersion and density imaging (NODDI) are widely used models to infer microstructural features in the brain from diffusion-weighted MRI. Several studies have recently applied both models to increase sensitivity to biological changes, however, it remains uncertain how these measures are associated. Here we show that cortical distributions of DTI and NODDI are associated depending on the choice of b-value, a factor reflecting strength of diffusion weighting gradient. We analyzed a combination of high, intermediate and low b-value data of multi-shell diffusion-weighted MRI (dMRI) in healthy 456 subjects of the Human Connectome Project using NODDI, DTI and a mathematical conversion from DTI to NODDI. Cortical distributions of DTI and DTI-derived NODDI metrics were remarkably associated with those in NODDI, particularly when applied highly diffusion-weighted data (b-value = 3000 sec/mm2). This was supported by simulation analysis, which revealed that DTI-derived parameters with lower b-value datasets suffered from errors due to heterogeneity of cerebrospinal fluid fraction and partial volume. These findings suggest that high b-value DTI redundantly parallels with NODDI-based cortical neurite measures, but the conventional low b-value DTI is hard to reasonably characterize cortical microarchitecture.
- 22 August 2019
- Published by Springer Nature in Scientific Reports
- Vol. 9 (1) , 1-12
Open AccessDiffusion Tensor Model links to Neurite Orientation Dispersion and Density Imaging at high b-value in Cerebral Cortical Gray Matter
Diffusion tensor imaging (DTI) and neurite orientation dispersion and density imaging (NODDI) are widely used models to infer microstructural features in the brain from diffusion-weighted MRI. Several studies have recently applied both models to increase sensitivity to biological changes, however, it remains uncertain how these measures are associated. Here we show that cortical distributions of DTI and NODDI are associated depending on the choice of b-value, a factor reflecting strength of diffusion weighting gradient. We analyzed a combination of high, intermediate and low b-value data of multi-shell diffusion-weighted MRI (dMRI) in healthy 456 subjects of the Human Connectome Project using NODDI, DTI and a mathematical conversion from DTI to NODDI. Cortical distributions of DTI and DTI-derived NODDI metrics were remarkably associated with those in NODDI, particularly when applied highly diffusion-weighted data (b-value = 3000 sec/mm2). This was supported by simulation analysis, which revealed that DTI-derived parameters with lower b-value datasets suffered from errors due to heterogeneity of cerebrospinal fluid fraction and partial volume. These findings suggest that high b-value DTI redundantly parallels with NODDI-based cortical neurite measures, but the conventional low b-value DTI is hard to reasonably characterize cortical microarchitecture.
- Open Access
- 1 November 2018
- Published by Elsevier in NeuroImage
- Vol. 182, 488-499
Neurite imaging reveals microstructural variations in human cerebral cortical gray matter
- 1 November 2018
- Published by Elsevier in NeuroImage
- Vol. 182, 488-499
Open AccessNeurite imaging reveals microstructural variations in human cerebral cortical gray matter
- 1 May 2018
- Published by Elsevier in NeuroImage
- Vol. 172, 357-368
Deciphering the microstructure of hippocampal subfields with in vivo DTI and NODDI: Applications to experimental multiple sclerosis
- 1 May 2018
- Published by Elsevier in NeuroImage
- Vol. 172, 357-368
Deciphering the microstructure of hippocampal subfields with in vivo DTI and NODDI: Applications to experimental multiple sclerosis
- Open Access
- 19 January 2018
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 13 (1) , e0189493
Magnetic resonance angiography with compressed sensing: An evaluation of moyamoya disease
Compressed sensing (CS) reconstructions of under-sampled measurements generate missing data based on assumptions of image sparsity. Non-contrast time-of-flight MR angiography (TOF-MRA) is a good candidate for CS based acceleration, as MRA images feature bright trees of sparse vessels over a well-suppressed anatomical background signal. A short scan time derived from CS is beneficial for patients of moyamoya disease (MMD) because of the frequency of MR scans. The purpose of this study was to investigate the reliability of TOF-MRA with CS in the evaluation of MMD. Twenty-two patients were examined using TOF-MRA with CS (CS-TOF) and parallel imaging (PI-TOF). The acceleration factors were 3 (CS3) and 5 (CS5) for CS-TOF, and 3 (PI3) for PI-TOF. Two neuroradiologists evaluated the MMD grading according to stenosis/occlusion scores using the modified Houkin’s system, and the visibility of moyamoya vessels (MMVs) using a 3-point scale. Concordance was calculated with Cohen’s κ. The numbers of MMVs in the basal ganglia were compared using Bland-Altman analysis and Wilcoxon’s signed-rank tests. MRA scan times were 4:07, 3:53, and 2:42 for PI3, CS3, and CS5, respectively. CS-reconstruction completed within 10 minutes. MMD grading and MMV visibility scales showed excellent correlation (κ > .966). Although the number of MMVs was significantly higher in CS3 than in PI3 (p < .0001) and CS5 (p < .0001), Bland-Altman analysis showed a good agreement between PI3, CS3, and CS5. Compressed sensing can accelerate TOF-MRA with improved visualization of small collaterals in equivalent time (CS3) or equivalent results in a shorter scan time (CS5).
- 19 January 2018
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 13 (1) , e0189493
Open AccessMagnetic resonance angiography with compressed sensing: An evaluation of moyamoya disease
Compressed sensing (CS) reconstructions of under-sampled measurements generate missing data based on assumptions of image sparsity. Non-contrast time-of-flight MR angiography (TOF-MRA) is a good candidate for CS based acceleration, as MRA images feature bright trees of sparse vessels over a well-suppressed anatomical background signal. A short scan time derived from CS is beneficial for patients of moyamoya disease (MMD) because of the frequency of MR scans. The purpose of this study was to investigate the reliability of TOF-MRA with CS in the evaluation of MMD. Twenty-two patients were examined using TOF-MRA with CS (CS-TOF) and parallel imaging (PI-TOF). The acceleration factors were 3 (CS3) and 5 (CS5) for CS-TOF, and 3 (PI3) for PI-TOF. Two neuroradiologists evaluated the MMD grading according to stenosis/occlusion scores using the modified Houkin’s system, and the visibility of moyamoya vessels (MMVs) using a 3-point scale. Concordance was calculated with Cohen’s κ. The numbers of MMVs in the basal ganglia were compared using Bland-Altman analysis and Wilcoxon’s signed-rank tests. MRA scan times were 4:07, 3:53, and 2:42 for PI3, CS3, and CS5, respectively. CS-reconstruction completed within 10 minutes. MMD grading and MMV visibility scales showed excellent correlation (κ > .966). Although the number of MMVs was significantly higher in CS3 than in PI3 (p < .0001) and CS5 (p < .0001), Bland-Altman analysis showed a good agreement between PI3, CS3, and CS5. Compressed sensing can accelerate TOF-MRA with improved visualization of small collaterals in equivalent time (CS3) or equivalent results in a shorter scan time (CS5).
- 26 June 2015
- Published by Oxford University Press (OUP) in Japanese Journal of Clinical Oncology
- Vol. 45 (9) , 892-893
Tracheal obstruction caused by cervical malignant peripheral nerve sheath tumor.
- 26 June 2015
- Published by Oxford University Press (OUP) in Japanese Journal of Clinical Oncology
- Vol. 45 (9) , 892-893
Tracheal obstruction caused by cervical malignant peripheral nerve sheath tumor.