Microhardness of bi-antibiotic-eluting bone cement scaffolds
Open Access
- 8 October 2012
- journal article
- Published by Springer Nature in Progress in Biomaterials
- Vol. 1 (1) , 3
Abstract
Bi-antibiotic-impregnated bone cements (BIBCs) are widely used in orthopaedics as a prophylactic agent (depot) to address post-surgical infections. Although hardness is widely considered a viable index to measure the integrity of the cement structure, there are few specific studies involving changes in hardness characteristics of BIBCs post elution of high doses of two widely used antibiotics: tobramycin and gentamicin. Increased doses of antibiotics and increased duration of elution may also decrease the hardness of polymethyl methacrylate (PMMA) bone cement, thus increasing the chances of shattering, scratching, and deformation. In this project, we have investigated the changes in surface hardness of five different antibiotic-loaded specimens: 0.5 g tobramycin and 0.5 g gentamicin together, 1 g tobramycin, 1 g gentamicin, 5 g tobramycin and 5 g gentamicin together, and 10 g tobramycin (each added to 40 g of PMMA), post elution for various time periods (1, 3, and 21 days). The effect of hydration on the hardness of bone cement was studied to replicate in vivo conditions. The micro-indentation tester (Buehler m5103) was utilized to determine if the increased antibiotic loads would compromise the integrity of the bone cement matrix. The results demonstrated that the amount of drug initially incorporated determined the hardness of the cement post elution. As compared to the control (no antibiotic), specimens containing 1 and 10 g of antibiotic exhibited over 50% and 73% decrease in hardness, respectively. The different treatment durations (post 1 day) as well as the hydration conditions had insignificant effect on the hardness of the cement.Keywords
This publication has 33 references indexed in Scilit:
- Effect of vacuum-treatment on deformation properties of PMMA bone cementJournal of the Mechanical Behavior of Biomedical Materials, 2012
- Microindentation for in vivo measurement of bone tissue mechanical properties in humansJournal of Bone and Mineral Research, 2010
- Biomechanical modeling of acetabular component polyethylene stresses, fracture risk, and wear rate following press‐fit implantationJournal of Orthopaedic Research, 2009
- Enhancement of antibiotic elution from acrylic bone cementJournal of Biomedical Materials Research Part B: Applied Biomaterials, 2009
- Properties of antibiotic‐loaded acrylic bone cements for use in cemented arthroplasties: A state‐of‐the‐art reviewJournal of Biomedical Materials Research Part B: Applied Biomaterials, 2008
- Alternative acrylic bone cement formulations for cemented arthroplasties: Present status, key issues, and future prospectsJournal of Biomedical Materials Research Part B: Applied Biomaterials, 2007
- Mechanical effects of the use of vancomycin and meropenem in acrylic bone cementActa Orthopaedica, 2006
- Treatment of deep infection of the hip associated with massive bone lossThe Journal of Bone and Joint Surgery. British volume, 2005
- Mechanical characteristics of antibiotic-laden bone cementActa Orthopaedica, 2002
- Effect of antibiotics on the properties of poly(methylmethacrylate)‐based bone cementJournal of Biomedical Materials Research, 2002