Mrinal Musib
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Mrinal Musib has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
- Jeremy Jones
Department of Orthopaedic Surgery and Rehabilitation Medicine, SUNY Downstate Medical Center, Brooklyn, NY, 11203, USA
1 shared publication - Karunesh Chakote
Department of Orthopaedic Surgery and Rehabilitation Medicine, SUNY Downstate Medical Center, Brooklyn, NY, 11203, USA
1 shared publication - Subrata Saha
Department of Orthopaedic Surgery and Rehabilitation Medicine, SUNY Downstate Medical Center, Brooklyn, NY, 11203, USA.
1 shared publication - Westley Hayes
Department of Orthopaedic Surgery and Rehabilitation Medicine, SUNY Downstate Medical Center, Brooklyn, NY, 11203, USA
1 shared publication
Latest Publications
- Open Access
- 8 October 2012
- Published by Springer Nature in Progress in Biomaterials
- Vol. 1 (1) , 3
Microhardness of bi-antibiotic-eluting bone cement scaffolds
Bi-antibiotic-impregnated bone cements (BIBCs) are widely used in orthopaedics as a prophylactic agent (depot) to address post-surgical infections. Although hardness is widely considered a viable index to measure the integrity of the cement structure, there are few specific studies involving changes in hardness characteristics of BIBCs post elution of high doses of two widely used antibiotics: tobramycin and gentamicin. Increased doses of antibiotics and increased duration of elution may also decrease the hardness of polymethyl methacrylate (PMMA) bone cement, thus increasing the chances of shattering, scratching, and deformation. In this project, we have investigated the changes in surface hardness of five different antibiotic-loaded specimens: 0.5 g tobramycin and 0.5 g gentamicin together, 1 g tobramycin, 1 g gentamicin, 5 g tobramycin and 5 g gentamicin together, and 10 g tobramycin (each added to 40 g of PMMA), post elution for various time periods (1, 3, and 21 days). The effect of hydration on the hardness of bone cement was studied to replicate in vivo conditions. The micro-indentation tester (Buehler m5103) was utilized to determine if the increased antibiotic loads would compromise the integrity of the bone cement matrix. The results demonstrated that the amount of drug initially incorporated determined the hardness of the cement post elution. As compared to the control (no antibiotic), specimens containing 1 and 10 g of antibiotic exhibited over 50% and 73% decrease in hardness, respectively. The different treatment durations (post 1 day) as well as the hydration conditions had insignificant effect on the hardness of the cement.
- 8 October 2012
- Published by Springer Nature in Progress in Biomaterials
- Vol. 1 (1) , 3
Open AccessMicrohardness of bi-antibiotic-eluting bone cement scaffolds
Bi-antibiotic-impregnated bone cements (BIBCs) are widely used in orthopaedics as a prophylactic agent (depot) to address post-surgical infections. Although hardness is widely considered a viable index to measure the integrity of the cement structure, there are few specific studies involving changes in hardness characteristics of BIBCs post elution of high doses of two widely used antibiotics: tobramycin and gentamicin. Increased doses of antibiotics and increased duration of elution may also decrease the hardness of polymethyl methacrylate (PMMA) bone cement, thus increasing the chances of shattering, scratching, and deformation. In this project, we have investigated the changes in surface hardness of five different antibiotic-loaded specimens: 0.5 g tobramycin and 0.5 g gentamicin together, 1 g tobramycin, 1 g gentamicin, 5 g tobramycin and 5 g gentamicin together, and 10 g tobramycin (each added to 40 g of PMMA), post elution for various time periods (1, 3, and 21 days). The effect of hydration on the hardness of bone cement was studied to replicate in vivo conditions. The micro-indentation tester (Buehler m5103) was utilized to determine if the increased antibiotic loads would compromise the integrity of the bone cement matrix. The results demonstrated that the amount of drug initially incorporated determined the hardness of the cement post elution. As compared to the control (no antibiotic), specimens containing 1 and 10 g of antibiotic exhibited over 50% and 73% decrease in hardness, respectively. The different treatment durations (post 1 day) as well as the hydration conditions had insignificant effect on the hardness of the cement.
- Open Access
- 31 December 2011
- Published by Scientific and Academic Publishing in Nanoscience and Nanotechnology
- Vol. 1 (2) , 48-53
Phagocytosis of Simulated Nano-wear Debris by Osteoblasts
In this study I have used well characterized simulated wear-nano-particles of ultra-high molecular weight polyethylene (UHMWPE) of known size and shape to study particulate phagocytosis by MG63 osteoblast-like cells. The particles were treated to decrease their propensity to form aggregates in aqueous suspension and scanning electron microscopy (SEM) was performed to image them as individual particles on 0.01 µm pore size polycarbonate filter membranes. These images were further subjected to morphometric analysis of the particles using ASTM F1877 descriptors [equivalent circle diameter (ECD in μm), aspect ratio (AR), elongation (E), roundness (R), and formfactor (FF)]. The mean (±SD) ECD of the particles were 0.056±0.03 µm. They were subsequently introduced to confluent MG63 cells at particle:cell ratio of 100:1 and incubated for 24 h. Transmission electron micrography (TEM) showed the nanoparticles inside the cytosol. No time dependent response was observed beyond 24 h. The nanoparticles seemed to re-agglomerate once inside the cell. The damage to the cells was evident from the compromised cell membrane. This study will help further our knowledge of the wear-mediated osteolytic process.
- 31 December 2011
- Published by Scientific and Academic Publishing in Nanoscience and Nanotechnology
- Vol. 1 (2) , 48-53
Open AccessPhagocytosis of Simulated Nano-wear Debris by Osteoblasts
In this study I have used well characterized simulated wear-nano-particles of ultra-high molecular weight polyethylene (UHMWPE) of known size and shape to study particulate phagocytosis by MG63 osteoblast-like cells. The particles were treated to decrease their propensity to form aggregates in aqueous suspension and scanning electron microscopy (SEM) was performed to image them as individual particles on 0.01 µm pore size polycarbonate filter membranes. These images were further subjected to morphometric analysis of the particles using ASTM F1877 descriptors [equivalent circle diameter (ECD in μm), aspect ratio (AR), elongation (E), roundness (R), and formfactor (FF)]. The mean (±SD) ECD of the particles were 0.056±0.03 µm. They were subsequently introduced to confluent MG63 cells at particle:cell ratio of 100:1 and incubated for 24 h. Transmission electron micrography (TEM) showed the nanoparticles inside the cytosol. No time dependent response was observed beyond 24 h. The nanoparticles seemed to re-agglomerate once inside the cell. The damage to the cells was evident from the compromised cell membrane. This study will help further our knowledge of the wear-mediated osteolytic process.
- Open Access
- 1 November 2011
- Published by Scientific and Academic Publishing in International Journal of Biological Engineering
- Vol. 1 (1) , 6-10
A Review of the History and Role of UHMWPE as A Component in Total Joint Replacements
Since its introduction as a bearing component for Total Joint Replacements (TJR) by Dr. Charnley in the early 1960’s, Ultra-high molecular weight polyethylene (UHMWPE) has become the gold standard to fabricate one of the articulating surfaces of total hip, total knee and total shoulder prostheses. More than a million TJR’s are performed every year and is a multi-billion dollar industry. In-spite-of the overwhelming success of this medical procedure, aseptic loosening as a result of wear limits its longevity to 15-20 years. This review article deals with the history of UHMWPE, its material properties that make it an ideal candidate for total joints, implant-component fabrication procedures and provides insights as to why some of the implants eventually fail. Alternate bearing components like Co-Cr and Ti alloys and ceramics are beyond the scope of this review.
- 1 November 2011
- Published by Scientific and Academic Publishing in International Journal of Biological Engineering
- Vol. 1 (1) , 6-10
Open AccessA Review of the History and Role of UHMWPE as A Component in Total Joint Replacements
Since its introduction as a bearing component for Total Joint Replacements (TJR) by Dr. Charnley in the early 1960’s, Ultra-high molecular weight polyethylene (UHMWPE) has become the gold standard to fabricate one of the articulating surfaces of total hip, total knee and total shoulder prostheses. More than a million TJR’s are performed every year and is a multi-billion dollar industry. In-spite-of the overwhelming success of this medical procedure, aseptic loosening as a result of wear limits its longevity to 15-20 years. This review article deals with the history of UHMWPE, its material properties that make it an ideal candidate for total joints, implant-component fabrication procedures and provides insights as to why some of the implants eventually fail. Alternate bearing components like Co-Cr and Ti alloys and ceramics are beyond the scope of this review.
- Open Access
- 31 October 2011
- Published by Scientific and Academic Publishing in American Journal of Biomedical Engineering
- Vol. 1 (1) , 7-12
Response to Ultra-high Molecular Weight Polyethylene Particles
Ultrahigh molecular weight polyethylene (UHMWPE) is widely used in the field of orthopedics to fabricate various orthopedic total joint (primarily hip, knee and shoulder) device components. In spite of its biocompatibility and excellent mechanical properties, wear debris particles are released during use at the articulating surfaces, usually at the implant-implant, bone-implant and cement-bone and cement-implant interfaces. Prior studies have shown that these wear debris particles are responsible for periprosthetic bone resorption (wear-mediated osteolysis) which leads to implant loosening and eventually failure of the prosthetic device. Previously investigators have implicated the size, shape, and number of UHMWPE wear particles released from implants in vivo and in situ to the wear-mediated-osteolytic phenomenon. In this short review I will discuss some of the in vitro and in vivo studies pertaining to the response to the wear-debris particles.
- 31 October 2011
- Published by Scientific and Academic Publishing in American Journal of Biomedical Engineering
- Vol. 1 (1) , 7-12
Open AccessResponse to Ultra-high Molecular Weight Polyethylene Particles
Ultrahigh molecular weight polyethylene (UHMWPE) is widely used in the field of orthopedics to fabricate various orthopedic total joint (primarily hip, knee and shoulder) device components. In spite of its biocompatibility and excellent mechanical properties, wear debris particles are released during use at the articulating surfaces, usually at the implant-implant, bone-implant and cement-bone and cement-implant interfaces. Prior studies have shown that these wear debris particles are responsible for periprosthetic bone resorption (wear-mediated osteolysis) which leads to implant loosening and eventually failure of the prosthetic device. Previously investigators have implicated the size, shape, and number of UHMWPE wear particles released from implants in vivo and in situ to the wear-mediated-osteolytic phenomenon. In this short review I will discuss some of the in vitro and in vivo studies pertaining to the response to the wear-debris particles.