Abstract
Background: The stability of implant-abutment connection is crucial to minimize mechanical and biological complications. Therefore, an assessment of the microgap behavior and abutment displacement in different implant-abutment designs was performed. Methods: Four implant systems were tested, three with a conical implant-abutment connection based on friction fit and a cone angle < 12 ° (Medentika, Medentis, NobelActive) and a system with an angulated connection (< 40°) (Semados). In different static loading conditions (30 N − 90º, 100 N − 90º, 200 N − 30º) the microgap and abutment displacement was evaluated using synchrotron-based microtomography and phase-contrast radioscopy with numerical forward simulation of the optical Fresnel propagation yielding an accuracy down to 0.1 μm. Results: Microgaps were present in all implant systems prior to loading (0.15–9 μm). Values increased with mounting force and angle up to 40.5 μm at an off axis loading of 100 N in a 90° angle. Conclusions: In contrast to the implant-abutment connection with a large cone angle (45°), the conical connections based on a friction fit (small cone angles with < 12°) demonstrated an abutment displacement which resulted in a deformation of the outer implant wall. The design of the implant-abutment connection seems to be crucial for the force distribution on the implant wall which might influence peri-implant bone stability.Keywords
Funding Information
- Albert-Ludwigs-Universität Freiburg im Breisgau
This publication has 43 references indexed in Scilit:
- Displacement and performance of abutments in narrow-diameter implants with different internal connectionsThe Journal of Prosthetic Dentistry, 2022
- Synchrotron-based micro computed tomography investigation of the implant-abutment fatigue-induced microgap changesJournal of the Mechanical Behavior of Biomedical Materials, 2021
- Fatigue induced changes in conical implant–abutment connectionsDental Materials, 2015
- Evaluation of survival and success rates of dental implants reported in longitudinal studies with a follow-up period of at least 10 years: a systematic reviewInternational Journal of Oral and Maxillofacial Surgery, 2015
- Implant-abutment interface: A comparison of the ultimate force to failure among narrow-diameter implant systemsThe Journal of Prosthetic Dentistry, 2014
- Wear at the titanium–titanium and the titanium–zirconia implant–abutment interface: A comparative in vitro studyDental Materials, 2012
- Influence of the interface design on the yield force of the implant–abutment complex before and after cyclic mechanical loadingJournal of Prosthodontic Research, 2012
- High-resolution tomography of cracks, voids and micro-structure in greywacke and limestoneJournal of Structural Geology, 2008
- Influence of implant length and diameter on stress distribution: A finite element analysisThe Journal of Prosthetic Dentistry, 2004
- Maschinenelemente1976