Florian Kernen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Florian Kernen has a total of 62 co-authors. Here are the top co-authors by number of shared publications:
Katja Nelson
Department of Oral‐ and Maxillofacial Surgery University Medical Center, Faculty of Medicine, University of Freiburg Germany
9 shared publications- Kirstin Vach
Center for Data Science, Eberswalde University for Sustainable Development, Schicklerstr. 5, 16225 Eberswalde, Germany
6 shared publications - Benedikt Christopher Spies
Department of Prosthetic Dentistry, Center for Dental Medicine, Medical Center-University of Freiburg, Faculty of Medicine, University of Freiburg, Freiburg, Germany
4 shared publications - Katja Nelson
Faculty of Medicine, University of Freiburg, Freiburg, Germany
4 shared publications Kirstin Vach
Institute of Medical Biometry and Statistics, Medical Center – University of Freiburg, Faculty of Medicine University of Freiburg Freiburg Germany
3 shared publicationsSusanne Nahles
Department of Prosthetic Dentistry, Medical Center – University of Freiburg, Faculty of Medicine University of Freiburg Freiburg Germany
3 shared publications
Latest Publications
- Open Access
- 26 February 2026
- Published by Wiley in Journal of Periodontology
Twenty‐four month clinical outcomes of modified coronally advanced tunnel technique with leukocyte‐ and platelet‐rich fibrin–functionalized porcine dermal matrix for single/multiple gingival recessions
Background: To report 24‐month clinical and 3D outcomes of single and multiple RT1 and RT2 gingival recessions treated with the modified coronally advanced tunnel (MCAT) technique and an L‐PRF‐functionalized porcine dermal matrix (PDM), as long‐term data on PDM in root coverage are scarce. Methods: Patients with single or multiple RT1 and RT2 recessions in the maxilla or mandible were treated with MCAT and L‐PRF‐functionalized PDM. Conventional impressions taken preoperatively and at 24 months were poured as casts, digitized, and aligned as standard tessellation language (STL) files for quantitative analysis. Outcomes were recession depth (RD), mean and complete root coverage (mRC, cRC), mean recession reduction (mRR), and gingival thickness (GT). Mixed linear models accounting for patient‐level clustering were used. Results: Eighty‐three teeth in 20 patients were available for 24‐month analysis. Healing was uneventful. Mean baseline RD was 1.31 ± 0.86 mm. At 24 months, mRC was 80.17 ± 56.68%, cRC 34.78%, and mRR 1.01 ± 0.84 mm. Mean GT gain was 0.22 ± 0.40 mm. Root coverage and GT changes were similar for RT1 and RT2 defects and were not influenced by tooth type or jaw. Conclusions: Within the limitations of this prospective single‐arm clinical trial, MCAT with a leukocyte‐ and platelet‐rich fibrin (L‐PRF) ‐functionalized PDM provided stable 24‐month root coverage and modest GT gain in RT1 and RT2 gingival recessions. These descriptive findings support the clinical applicability of this CTG‐sparing approach and underline the need for randomized controlled trials with patient‐reported outcomes to compare it with connective tissue grafting. Plain language summary: Gum recession, where the gum pulls away and exposes the tooth root, can cause sensitivity, esthetic concerns, and tissue loss. In this study we treated 83 teeth in 20 adults with gum recession using a minimally invasive tunnel technique combined with a soft tissue replacement material made from porcine (pig) skin that was coated with a blood concentrate prepared from the patient. We followed the teeth for 2 years and used 3‐dimensional (3D) digital models made from dental casts to measure changes in gum position and thickness. On average, exposed root surfaces were reduced by about 80%, and in roughly one third of teeth the roots were fully covered again. The gums also became slightly thicker. Healing was uncomplicated, and results were similar in different tooth types and positions. Because this approach does not require taking a small piece of tissue from the roof of the mouth (connective tissue graft), it may reduce surgical discomfort while still providing stable coverage of exposed roots. However, direct comparisons with the current gold standard, connective tissue grafting, in randomized controlled trials are still needed to confirm these findings and to better understand patient‐reported benefits such as pain and satisfaction.
- 26 February 2026
- Published by Wiley in Journal of Periodontology
Open AccessTwenty‐four month clinical outcomes of modified coronally advanced tunnel technique with leukocyte‐ and platelet‐rich fibrin–functionalized porcine dermal matrix for single/multiple gingival recessions
Background: To report 24‐month clinical and 3D outcomes of single and multiple RT1 and RT2 gingival recessions treated with the modified coronally advanced tunnel (MCAT) technique and an L‐PRF‐functionalized porcine dermal matrix (PDM), as long‐term data on PDM in root coverage are scarce. Methods: Patients with single or multiple RT1 and RT2 recessions in the maxilla or mandible were treated with MCAT and L‐PRF‐functionalized PDM. Conventional impressions taken preoperatively and at 24 months were poured as casts, digitized, and aligned as standard tessellation language (STL) files for quantitative analysis. Outcomes were recession depth (RD), mean and complete root coverage (mRC, cRC), mean recession reduction (mRR), and gingival thickness (GT). Mixed linear models accounting for patient‐level clustering were used. Results: Eighty‐three teeth in 20 patients were available for 24‐month analysis. Healing was uneventful. Mean baseline RD was 1.31 ± 0.86 mm. At 24 months, mRC was 80.17 ± 56.68%, cRC 34.78%, and mRR 1.01 ± 0.84 mm. Mean GT gain was 0.22 ± 0.40 mm. Root coverage and GT changes were similar for RT1 and RT2 defects and were not influenced by tooth type or jaw. Conclusions: Within the limitations of this prospective single‐arm clinical trial, MCAT with a leukocyte‐ and platelet‐rich fibrin (L‐PRF) ‐functionalized PDM provided stable 24‐month root coverage and modest GT gain in RT1 and RT2 gingival recessions. These descriptive findings support the clinical applicability of this CTG‐sparing approach and underline the need for randomized controlled trials with patient‐reported outcomes to compare it with connective tissue grafting. Plain language summary: Gum recession, where the gum pulls away and exposes the tooth root, can cause sensitivity, esthetic concerns, and tissue loss. In this study we treated 83 teeth in 20 adults with gum recession using a minimally invasive tunnel technique combined with a soft tissue replacement material made from porcine (pig) skin that was coated with a blood concentrate prepared from the patient. We followed the teeth for 2 years and used 3‐dimensional (3D) digital models made from dental casts to measure changes in gum position and thickness. On average, exposed root surfaces were reduced by about 80%, and in roughly one third of teeth the roots were fully covered again. The gums also became slightly thicker. Healing was uncomplicated, and results were similar in different tooth types and positions. Because this approach does not require taking a small piece of tissue from the roof of the mouth (connective tissue graft), it may reduce surgical discomfort while still providing stable coverage of exposed roots. However, direct comparisons with the current gold standard, connective tissue grafting, in randomized controlled trials are still needed to confirm these findings and to better understand patient‐reported benefits such as pain and satisfaction.
- Open Access
- 30 January 2026
- Published by Wiley in Clinical Oral Implants Research
- Vol. 37 (4) , 426-438
Immunohistological Evaluation of Peri‐Implant Soft Tissue Grafting Using a Porcine Dermal Matrix—A Human Histological Study
Introduction: The aim was the immunohistological evaluation of a porcine dermal matrix (PDM) in comparison to a non‐augmented control group for peri‐implant tissue thickening. Materials and Methods: This human histological study involved the placement of PDM in the test group (20 patients) during implant placement, while the control group underwent implant placement without grafting (20 patients). Postoperative clinical evaluations were conducted, and biopsies were obtained after 3 months. Histomorphometric evaluation utilized H&E staining. Immunohistological analysis included CD31, PSR, TE‐7, CD3, CD20, CD138, and CD68. Results: A total of 40 patients (17 females, 23 males; 60.62 years) were included. Though more frequent gingival redness occurred during wound healing in the PDM, the groups showed no significant differences in epithelial thickness ( p = 0.63), rete ridges ( p = 0.53), papilla density ( p = 0.626), papilla complexity ( p = 0.053), vascularization ( p = 0.052), connective tissue morphology ( p = 0.127), collagen differentiation ( p = 0.41), and CD3 + ( p = 0.85) and CD138 + cells ( p = 0.33). The PDM group showed significantly more CD68 + cells ( p = 0.049) and CD20 + cells ( p = 0.046), which correlates with a potentially distinct immune response caused by the PDM. Conclusion: The PDM used in this study exhibited no significant differences regarding epithelial changes, vascularization, tissue morphology, and collagen differentiation compared to a healthy control sample 3 months after grafting. The PDM group demonstrated a significantly higher frequency of CD68 + and CD20 + cells. The noticeable interindividual variation in immunoprofiles and clinical relevance of these findings should be investigated in future research.
- 30 January 2026
- Published by Wiley in Clinical Oral Implants Research
- Vol. 37 (4) , 426-438
Open AccessImmunohistological Evaluation of Peri‐Implant Soft Tissue Grafting Using a Porcine Dermal Matrix—A Human Histological Study
Introduction: The aim was the immunohistological evaluation of a porcine dermal matrix (PDM) in comparison to a non‐augmented control group for peri‐implant tissue thickening. Materials and Methods: This human histological study involved the placement of PDM in the test group (20 patients) during implant placement, while the control group underwent implant placement without grafting (20 patients). Postoperative clinical evaluations were conducted, and biopsies were obtained after 3 months. Histomorphometric evaluation utilized H&E staining. Immunohistological analysis included CD31, PSR, TE‐7, CD3, CD20, CD138, and CD68. Results: A total of 40 patients (17 females, 23 males; 60.62 years) were included. Though more frequent gingival redness occurred during wound healing in the PDM, the groups showed no significant differences in epithelial thickness ( p = 0.63), rete ridges ( p = 0.53), papilla density ( p = 0.626), papilla complexity ( p = 0.053), vascularization ( p = 0.052), connective tissue morphology ( p = 0.127), collagen differentiation ( p = 0.41), and CD3 + ( p = 0.85) and CD138 + cells ( p = 0.33). The PDM group showed significantly more CD68 + cells ( p = 0.049) and CD20 + cells ( p = 0.046), which correlates with a potentially distinct immune response caused by the PDM. Conclusion: The PDM used in this study exhibited no significant differences regarding epithelial changes, vascularization, tissue morphology, and collagen differentiation compared to a healthy control sample 3 months after grafting. The PDM group demonstrated a significantly higher frequency of CD68 + and CD20 + cells. The noticeable interindividual variation in immunoprofiles and clinical relevance of these findings should be investigated in future research.
- Open Access
- 10 September 2025
- Published by Elsevier in Journal of Dentistry
- Vol. 162, 106099
Digital transformation in dentistry: Patterns of use among clinicians in Germany and Switzerland
- 10 September 2025
- Published by Elsevier in Journal of Dentistry
- Vol. 162, 106099
Open AccessDigital transformation in dentistry: Patterns of use among clinicians in Germany and Switzerland
- Open Access
- 14 August 2025
- Published by Wiley in Clinical and Experimental Dental Research
- Vol. 11 (5) , e70179
Synchrotron‐Based Analysis of Conical Implant–Abutment Connections Under Mechanical Load: How Embedding Materials Influence the Microgap and Implant Shoulder Deformation
Objectives: Dental implants have become a reliable solution for oral rehabilitation, but their long‐term success can be compromised by factors such as mechanical overload. To ensure the mechanical durability of implants, standardized testing in accordance with the DIN EN ISO 14801 is conducted, in which titanium implants (Young's modulus of approximately 100 GPa) are embedded in brass, a material with similarly high stiffness. However, the mechanical properties of brass differ significantly from those of alveolar bone, potentially affecting test outcomes. This study examines how different embedding materials affect the mechanical behavior of dental implants, specifically microgap changes and deformation at the IAC under load.Materials and Methods: Two conical dental implants were embedded in either methyl methacrylate‐based adhesive (PMMA) or brass. A 250 N load was applied at a 45° angle to the implants. Synchrotron‐based microcomputed tomography (µCT) was used to assess microgap formation and 3D deformation at the implant shoulder before and under load application. Deformation was analyzed using Avizo Fire software to estimate volumetric changes at the implant shoulder.Results: The results showed that implants embedded in brass exhibited larger microgap changes (53 μm) and greater deformation at the implant shoulder (32 μm) compared to those embedded in PMMA (microgap: 40 μm).Conclusion: The findings suggest that brass, with higher stiffness than PMMA or bone, does not accurately replicate the mechanical conditions of bone, leading to a difference in microgap behavior and deformation at the implant shoulder, suggesting a difference in the wear mechanism and stress‐strain distribution in the surrounding bone. These results question the use of brass in mechanical implant testing and highlight the need for more realistic embedding materials to improve the predictive value of implant testing.
- 14 August 2025
- Published by Wiley in Clinical and Experimental Dental Research
- Vol. 11 (5) , e70179
Open AccessSynchrotron‐Based Analysis of Conical Implant–Abutment Connections Under Mechanical Load: How Embedding Materials Influence the Microgap and Implant Shoulder Deformation
Objectives: Dental implants have become a reliable solution for oral rehabilitation, but their long‐term success can be compromised by factors such as mechanical overload. To ensure the mechanical durability of implants, standardized testing in accordance with the DIN EN ISO 14801 is conducted, in which titanium implants (Young's modulus of approximately 100 GPa) are embedded in brass, a material with similarly high stiffness. However, the mechanical properties of brass differ significantly from those of alveolar bone, potentially affecting test outcomes. This study examines how different embedding materials affect the mechanical behavior of dental implants, specifically microgap changes and deformation at the IAC under load.Materials and Methods: Two conical dental implants were embedded in either methyl methacrylate‐based adhesive (PMMA) or brass. A 250 N load was applied at a 45° angle to the implants. Synchrotron‐based microcomputed tomography (µCT) was used to assess microgap formation and 3D deformation at the implant shoulder before and under load application. Deformation was analyzed using Avizo Fire software to estimate volumetric changes at the implant shoulder.Results: The results showed that implants embedded in brass exhibited larger microgap changes (53 μm) and greater deformation at the implant shoulder (32 μm) compared to those embedded in PMMA (microgap: 40 μm).Conclusion: The findings suggest that brass, with higher stiffness than PMMA or bone, does not accurately replicate the mechanical conditions of bone, leading to a difference in microgap behavior and deformation at the implant shoulder, suggesting a difference in the wear mechanism and stress‐strain distribution in the surrounding bone. These results question the use of brass in mechanical implant testing and highlight the need for more realistic embedding materials to improve the predictive value of implant testing.
- Open Access
- 6 June 2025
- Published by Springer Nature in BMC Oral Health
- Vol. 25 (1) , 1-12
Optical measurement methods of the 3D-position stability of implant-abutment connections - an in vitro study
Introduction: For ideal occlusion and passive fit of implant-retained prosthetic restorations minimal tolerance of the position of the abutment in the implant after dis- and reassembly is essential. Methods to examine the three-dimensional (3D) positional stability of implant-abutment connections (IAC) vary and their accuracy and applicability have not been assessed. The aim of this study was to evaluate non-contact optical measurement devices for 3D-feasibility, accuracy, repeatability, time efficiency and complexity of use. Methods: Five devices capable of contactless, optical methods (Profile Projector; Digital Image Correlation (DIC); Profilometer; Confocal Technology; Coordinate Measuring Machine (CMM)) were examined regarding their 3D-feasibility, accuracy, repeatability, time efficiency and complexity. The parameters were quantified and scored using a decision matrix. In an experimental set-up the method (device) with the highest score was used to measure the position stability as follows: four implants with a butt joint (BJ) and a conical (CON) IAC were embedded in an aluminum block and dis- and reassembled ten times with the abutment screw being hand-tightened (∑1–5) and torque-tightened (∑6–10). Results: The CMM achieved the highest score in the decision matrix with 40/50 points (range: 10–50 points; 10 requirements not met, 50: requirements fully met) while the Profile Projector, the DIC, the Profilometer and the Confocal Technology achieved 30, 32, 34, 38 points, respectively. Using the CMM the mean rotational freedom in BJ vs. CON was 0.32° ± 0.16° vs. 0.21° ± 0.25° (hand-tightened) and 0.36° ± 0.09° vs. 0.20° ± 0.22° (ratchet), respectively. The maximum vertical deviation of the abutment position after re-assembly was 7.2 μm ± 2.1 μm (BJ) and 24.4 μm ± 2.1 μm (CON). Conclusion: The data acquired suggest that the CMM with its non-contact, optical measurement method is the most appropriate to investigate the 3D positional stability of the IAC in different implant systems. As previously described distinct differences between BJ and CON IACs were found. CON connections exhibit a higher vertical deviation when the system specific torque value was applied.
- 6 June 2025
- Published by Springer Nature in BMC Oral Health
- Vol. 25 (1) , 1-12
Open AccessOptical measurement methods of the 3D-position stability of implant-abutment connections - an in vitro study
Introduction: For ideal occlusion and passive fit of implant-retained prosthetic restorations minimal tolerance of the position of the abutment in the implant after dis- and reassembly is essential. Methods to examine the three-dimensional (3D) positional stability of implant-abutment connections (IAC) vary and their accuracy and applicability have not been assessed. The aim of this study was to evaluate non-contact optical measurement devices for 3D-feasibility, accuracy, repeatability, time efficiency and complexity of use. Methods: Five devices capable of contactless, optical methods (Profile Projector; Digital Image Correlation (DIC); Profilometer; Confocal Technology; Coordinate Measuring Machine (CMM)) were examined regarding their 3D-feasibility, accuracy, repeatability, time efficiency and complexity. The parameters were quantified and scored using a decision matrix. In an experimental set-up the method (device) with the highest score was used to measure the position stability as follows: four implants with a butt joint (BJ) and a conical (CON) IAC were embedded in an aluminum block and dis- and reassembled ten times with the abutment screw being hand-tightened (∑1–5) and torque-tightened (∑6–10). Results: The CMM achieved the highest score in the decision matrix with 40/50 points (range: 10–50 points; 10 requirements not met, 50: requirements fully met) while the Profile Projector, the DIC, the Profilometer and the Confocal Technology achieved 30, 32, 34, 38 points, respectively. Using the CMM the mean rotational freedom in BJ vs. CON was 0.32° ± 0.16° vs. 0.21° ± 0.25° (hand-tightened) and 0.36° ± 0.09° vs. 0.20° ± 0.22° (ratchet), respectively. The maximum vertical deviation of the abutment position after re-assembly was 7.2 μm ± 2.1 μm (BJ) and 24.4 μm ± 2.1 μm (CON). Conclusion: The data acquired suggest that the CMM with its non-contact, optical measurement method is the most appropriate to investigate the 3D positional stability of the IAC in different implant systems. As previously described distinct differences between BJ and CON IACs were found. CON connections exhibit a higher vertical deviation when the system specific torque value was applied.
- Top Cited PapersOpen Access
- 4 January 2025
- Published by Elsevier in Journal of Dentistry
- Vol. 153, 105559
Accuracy of digital and conventional implant impressions in edentulous jaws: A clinical comparative study
- 4 January 2025
- Published by Elsevier in Journal of Dentistry
- Vol. 153, 105559
Top Cited PapersOpen AccessAccuracy of digital and conventional implant impressions in edentulous jaws: A clinical comparative study
- Open Access
- 28 March 2024
- Published by Springer Nature in BMC Oral Health
- Vol. 24 (1) , 1-10
In vitro assessment of internal implant-abutment connections with different cone angles under static loading using synchrotron-based radiation
Background: The stability of implant-abutment connection is crucial to minimize mechanical and biological complications. Therefore, an assessment of the microgap behavior and abutment displacement in different implant-abutment designs was performed. Methods: Four implant systems were tested, three with a conical implant-abutment connection based on friction fit and a cone angle < 12 ° (Medentika, Medentis, NobelActive) and a system with an angulated connection (< 40°) (Semados). In different static loading conditions (30 N − 90º, 100 N − 90º, 200 N − 30º) the microgap and abutment displacement was evaluated using synchrotron-based microtomography and phase-contrast radioscopy with numerical forward simulation of the optical Fresnel propagation yielding an accuracy down to 0.1 μm. Results: Microgaps were present in all implant systems prior to loading (0.15–9 μm). Values increased with mounting force and angle up to 40.5 μm at an off axis loading of 100 N in a 90° angle. Conclusions: In contrast to the implant-abutment connection with a large cone angle (45°), the conical connections based on a friction fit (small cone angles with < 12°) demonstrated an abutment displacement which resulted in a deformation of the outer implant wall. The design of the implant-abutment connection seems to be crucial for the force distribution on the implant wall which might influence peri-implant bone stability.
- 28 March 2024
- Published by Springer Nature in BMC Oral Health
- Vol. 24 (1) , 1-10
Open AccessIn vitro assessment of internal implant-abutment connections with different cone angles under static loading using synchrotron-based radiation
Background: The stability of implant-abutment connection is crucial to minimize mechanical and biological complications. Therefore, an assessment of the microgap behavior and abutment displacement in different implant-abutment designs was performed. Methods: Four implant systems were tested, three with a conical implant-abutment connection based on friction fit and a cone angle < 12 ° (Medentika, Medentis, NobelActive) and a system with an angulated connection (< 40°) (Semados). In different static loading conditions (30 N − 90º, 100 N − 90º, 200 N − 30º) the microgap and abutment displacement was evaluated using synchrotron-based microtomography and phase-contrast radioscopy with numerical forward simulation of the optical Fresnel propagation yielding an accuracy down to 0.1 μm. Results: Microgaps were present in all implant systems prior to loading (0.15–9 μm). Values increased with mounting force and angle up to 40.5 μm at an off axis loading of 100 N in a 90° angle. Conclusions: In contrast to the implant-abutment connection with a large cone angle (45°), the conical connections based on a friction fit (small cone angles with < 12°) demonstrated an abutment displacement which resulted in a deformation of the outer implant wall. The design of the implant-abutment connection seems to be crucial for the force distribution on the implant wall which might influence peri-implant bone stability.
- Open Access
- 14 June 2023
- Published by Wiley in Clinical Oral Implants Research
- Vol. 34 (8) , 793-801
Enhancing intraoral scanner accuracy using scan aid for multiple implants in the edentulous arch: An in vivo study
Objectives: Intraoral scans of multiple implants in the edentulous arch are challenged by the absence of a distinct surface morphology between scan bodies. A scan aid was applied in such situation and evaluated for intraoral scanning accuracy in vivo.Materials and Methods: 87 implants in 22 patients were scanned with scan aid (SA) and without scan aid (NO) using two different intraoral scanners (CS3600 [CS] and TRIOS3 [TR]). Master casts were digitized by a laboratory scanner. Virtual models were superimposed using an inspection software and Linear deviation and precision were measured. Statistical analysis was performed using linear mixed models (α = .05).Results: Total mean linear deviation within the CS group was 189 μm without scan aid and 135 μm when using the scan aid. The TR group's total mean deviation was 165 μm with and without a scan aid. Significant improvement with scan aid was observed for the CS group (p = .001), and no difference was found in the TR group. 96% of scan bodies were successfully scanned in the TR‐SA group compared to 86% for the TR‐NO group, 83% for the CS‐SA, and 70% for the CS‐NO group, respectively.Conclusions: The evaluated scan aid improved linear deviation compared to unsplinted scans for the CS group but not for the TR group. These differences could originate from different scanning technologies used, active triangulation (CS) and confocal microscopy (TR). The scan aid improved the ability to recognize scan bodies successfully with both systems, which could have a favorable clinical impact overall.
- 14 June 2023
- Published by Wiley in Clinical Oral Implants Research
- Vol. 34 (8) , 793-801
Open AccessEnhancing intraoral scanner accuracy using scan aid for multiple implants in the edentulous arch: An in vivo study
Objectives: Intraoral scans of multiple implants in the edentulous arch are challenged by the absence of a distinct surface morphology between scan bodies. A scan aid was applied in such situation and evaluated for intraoral scanning accuracy in vivo.Materials and Methods: 87 implants in 22 patients were scanned with scan aid (SA) and without scan aid (NO) using two different intraoral scanners (CS3600 [CS] and TRIOS3 [TR]). Master casts were digitized by a laboratory scanner. Virtual models were superimposed using an inspection software and Linear deviation and precision were measured. Statistical analysis was performed using linear mixed models (α = .05).Results: Total mean linear deviation within the CS group was 189 μm without scan aid and 135 μm when using the scan aid. The TR group's total mean deviation was 165 μm with and without a scan aid. Significant improvement with scan aid was observed for the CS group (p = .001), and no difference was found in the TR group. 96% of scan bodies were successfully scanned in the TR‐SA group compared to 86% for the TR‐NO group, 83% for the CS‐SA, and 70% for the CS‐NO group, respectively.Conclusions: The evaluated scan aid improved linear deviation compared to unsplinted scans for the CS group but not for the TR group. These differences could originate from different scanning technologies used, active triangulation (CS) and confocal microscopy (TR). The scan aid improved the ability to recognize scan bodies successfully with both systems, which could have a favorable clinical impact overall.
- Top Cited PapersOpen Access
- 1 December 2022
- Published by Elsevier in The Journal of Prosthetic Dentistry
- Vol. 128 (6) , 1303-1309
Accuracy of intraoral scans: An in vivo study of different scanning devices
- 1 December 2022
- Published by Elsevier in The Journal of Prosthetic Dentistry
- Vol. 128 (6) , 1303-1309
Top Cited PapersOpen AccessAccuracy of intraoral scans: An in vivo study of different scanning devices