Optimization of couch translational corrections to compensate for rotational and deformable target deviations in image guided radiotherapy
- 10 September 2008
- journal article
- research article
- Published by Wiley in Medical Physics
- Vol. 35 (10) , 4375-4385
Abstract
The utilization of image‐guided radiotherapy (IGRT) technologies helps correct temporal and spatial deviations of the target volume relative to planned radiation beams. With the aid of these IGRT technologies, it becomes possible to better identify the target volume before and even during radiation treatment. However, since components of the detected deviations may be translational, rotational, and deformable, the question remains whether simple treatment‐couch translational movement can be optimized to compensate for these complicated deviations. Deviation of the target volume and changes in patient body shape from that acquired for treatment planning may further add to the variations from planned dose distribution. In this study, an optimization strategy is developed to investigate these issues. The optimization process involved the use of the hill climbing algorithm, the detected target volume and patient body shape, and the dose distribution based on acquired images at treatment. During the process, the planned dose distribution was iteratively adjusted to reflect the changes of depth and distance as the translational treatment couch movement was being optimized. The optimal treatment couch movement was considered achieved when the highest fraction of the detected target volume was covered by prescription dose. This optimization strategy was evaluated on clinical prostate cancer cases. For each of the cases, cone beam computed tomography (CBCT) images were acquired right after fiducial marker‐based kilovolt orthogonal imaging verification and setup adjustment. Based on the CBCT images, the clinical target volume at the treatment was delineated and the translational treatment‐couch movements were optimized with the developed strategy. The resultant dose coverage was compared to that without the optimization. The results showed that with the present strategy, rotational and deformable target deviations can be further compensated with translational couch correction.Keywords
This publication has 36 references indexed in Scilit:
- Inter- and Intrafractional Tumor and Organ Movement in Patients With Cervical Cancer Undergoing Radiotherapy: A Cinematic-MRI Point-of-Interest StudyInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2008
- On-line re-optimization of prostate IMRT plans for adaptive radiation therapyPhysics in Medicine & Biology, 2008
- Dosimetric effects of patient rotational setup errors on prostate IMRT treatmentsPhysics in Medicine & Biology, 2006
- An automatic CT-guided adaptive radiation therapy technique by online modification of multileaf collimator leaf positions for prostate cancerInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2005
- Use of deformed intensity distributions for on-line modification of image-guided IMRT to account for interfractional anatomic changesInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2005
- The impact of daily setup variations on head-and-neck intensity-modulated radiation therapyInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2005
- Implementation and validation of a three-dimensional deformable registration algorithm for targeted prostate cancer radiotherapyInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2005
- Adequate margins for random setup uncertainties in head-and-neck IMRTInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2005
- Combined error of patient positioning variability and prostate motion uncertainty in 3D conformal radiotherapy of localized prostate cancerInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 1996
- A 4-MV CT scanner for radiation therapy; spectral properties of the therapy beamMedical Physics, 1983