Effect of remote monitoring on patient-reported outcomes in European heart failure patients with an implantable cardioverter-defibrillator: primary results of the REMOTE-CIED randomized trial
Open Access
- 5 June 2019
- journal article
- research article
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 21 (9) , 1360-1368
Abstract
The European REMOTE-CIED study is the first randomized trial primarily designed to evaluate the effect of remote patient monitoring (RPM) on patient-reported outcomes in the first 2 years after implantation of an implantable cardioverter-defibrillator (ICD). The sample consisted of 595 European heart failure patients implanted with an ICD compatible with the Boston Scientific LATITUDE® RPM system. Patients were randomized to RPM plus a yearly in-clinic ICD check-up vs. 3–6-month in-clinic check-ups alone. At five points during the 2-year follow-up, patients completed questionnaires including the Kansas City Cardiomyopathy Questionnaire and Florida Patient Acceptance Survey (FPAS) to assess their heart failure-specific health status and ICD acceptance, respectively. Information on clinical status was obtained from patients’ medical records. Linear regression models were used to compare scores between groups over time. Intention-to-treat and per-protocol analyses showed no significant group differences in patients’ health status and ICD acceptance (subscale) scores (all Ps > 0.05). Exploratory subgroup analyses indicated a temporary improvement in device acceptance (FPAS total score) at 6-month follow-up for secondary prophylactic in-clinic patients only (P < 0.001). No other significant subgroup differences were observed. Large clinical trials have indicated that RPM can safely and effectively replace most in-clinic check-ups of ICD patients. The REMOTE-CIED trial results show that patient-reported health status and ICD acceptance do not differ between patients on RPM and patients receiving in-clinic check-ups alone in the first 2 years after ICD implantation. ClinicalTrials.gov Identifier: NCT01691586.Keywords
Funding Information
- Boston Scientific
This publication has 23 references indexed in Scilit:
- The patient perspective on remote monitoring of patients with an implantable cardioverter defibrillator: Narrative review and future directionsPacing and Clinical Electrophysiology, 2017
- Effect of Telemonitoring of Cardiac Implantable Electronic Devices on Healthcare Utilization: A Meta-Analysis of Randomized Controlled Trials in Patients with Heart FailureEuropean Journal of Heart Failure, 2016
- HRS Expert Consensus Statement on remote interrogation and monitoring for cardiovascular implantable electronic devicesHeart Rhythm, 2015
- Remote Monitoring of Implantable Cardioverter-DefibrillatorsJACC, 2015
- Patient perspective on remote monitoring of cardiovascular implantable electronic devices: rationale and design of the REMOTE-CIED studyNetherlands Heart Journal, 2014
- Cardiovascular Health: The Importance of Measuring Patient-Reported Health StatusCirculation, 2013
- Remote Monitoring Reduces Healthcare Use and Improves Quality of Care in Heart Failure Patients With Implantable DefibrillatorsCirculation, 2012
- Monitoring Device Acceptance in Implantable Cardioverter Defibrillator Patients Using the Florida Patient Acceptance SurveyPacing and Clinical Electrophysiology, 2012
- Remote Monitoring of Implantable Cardioverter Defibrillators versus Quarterly Device Interrogations in Clinic: Results from a Randomized Pilot Clinical TrialJournal of Cardiovascular Electrophysiology, 2010
- Development and evaluation of the Kansas City Cardiomyopathy Questionnaire: a new health status measure for heart failureJACC, 2000