Patient‐circumference‐adapted dose regulation in body computed tomography. a practical and flexible formula
Authors:
- 1 July 2005
- journal article
- research article
- Published by SAGE Publications in Acta Radiologica
- Vol. 46 (4) , 396-406
Abstract
Purpose: To illustrate that the attenuation formula based on monochromatic radiation in homogeneous objects may be used for dose regulation in body computed tomography (CT) based on patient circumference and using a simple cloth measuring tape.Material and Methods: Based on the attenuation formula for monochromatic radiation, the following Microsoft Excel equation was derived: mAsx = mAsn*EXP((0.693/HVT)*(Øx−Øn)/PI()), where mAsx(milliampere second) in a patient with circumference Øxis calculated based on the nominal mAsnset for a reference patient with the circumference Ønwith regard to indication, scan protocol, and available CT scanner. The HVT = half‐value thickness (object thickness change in cm affecting mAs setting by a factor of 2) resulting in the least mAs difference compared with published studies investigating the mAs needed for constant image noise in abdominal CT phantoms at 80–140 kVp was evaluated. Clinically recommended HVT values were applied to 20 patients undergoing abdominal CT using 130 effective mAs and 94 cm circumference as nominal settings, and an HVT of 9 cm.Results: The object‐sized dependent mAs for constant image noise at 80–140 kVp in 10–47 cm diameter abdominal phantoms (31–148 cm in circumference) differed, with few exceptions, by no more than 10% from those obtained with our formula using an HVT of 3.2–3.8 cm. An HVT of 9 cm in the patient study resulted in the same image noise–patient circumference relation as a phantom study using a “clinically adapted mAs” resulting in an acceptable noise according to diagnostic requirements. Clinical experiences recommend an HVT of about 8 cm for abdominal CT and 12 cm in thoracic CT. Changing the kVp from 120 to 80, 100, or 140 requires a mAs change roughly by factors of 4, 2, and 0.6, respectively, for constant image noise.Conclusion: Until fully automatic automatic exposure control systems have been introduced, applying the formula in a computer program provides the radiologist with an easy, quick, flexible, and practical instrument for reasonably good patient‐sized adjusted exposure levels in clinical practice.Keywords
This publication has 14 references indexed in Scilit:
- Strategies for CT Radiation Dose OptimizationRadiology, 2004
- Management of patient dose and image noise in routine pediatric CT abdominal examinationsEuropean Radiology, 2004
- Dose Reduction in Pediatric CT: A Rational ApproachRadiology, 2003
- Clinical Comparison of Standard-Dose and 50% Reduced—Dose Abdominal CT: Effect on Image QualityAmerican Journal of Roentgenology, 2002
- How do radiographic techniques affect image quality and patient doses in CT?Seminars in Ultrasound, CT and MRI, 2002
- Radiation Exposure in Computed TomographyMedical Physics, 2002
- Multidetector helical CT of the liver for tumor detection and characterizationEuropean Radiology, 2001
- A rational approach to dose reduction in CT: individualized scan protocolsEuropean Radiology, 2001
- Managing patient dose in computed tomographyAnnals of the ICRP, 2000
- Technique Factors and Image Quality as Functions of Patient Weight at Abdominal CTRadiology, 2000