Effect of Polar Protic and Polar Aprotic Solvents on Negative-Ion Electrospray Ionization and Chromatographic Separation of Small Acidic Molecules
Authors:
- 15 October 2012
- journal article
- research article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 84 (22) , 9942-9950
Abstract
A comprehensive study investigated the effect of polar protic (methanol and water) and polar aprotic (acetonitrile and acetone) solvents on the chromatographic separation and negative-ion electrospray (ESI) response of 49 diverse small, acidic molecules. Flow injection experiments on a triple quadrupole were used to measure the response in neat solvents after optimization of source conditions and implementation of a rigorous quality control program (the later ensured that changes in analyte response were due to the analyte/solvent measured and not changes in instrument performance over time). In all solvents, compounds with electron-withdrawing groups and extended conjugation ionized best due to resonance and inductive effects. Ionization was greatest in methanol or water for all compounds that elicited a response, thus revealing that enhanced sensitivity and lower limits of detection are achieved with polar protic solvents. Response in acetone was equal to or slightly lower than response in acetonitrile in flow injection experiments; however, the water/acetonitrile and water/acetone mobile phases produced the better chromatographic separation. Water/methanol produced slightly less satisfactory separation but the greatest overall response. This increase in response was attributed to the protic nature of methanol and the elution of compounds in a higher organic mobile phase composition (retention times were ∼30% later in methanol). This work is intended to facilitate rational liquid chromatography/mass spectrometry method development for small molecule applications, including metabolomics.Keywords
This publication has 22 references indexed in Scilit:
- Expanding Coverage of the Metabolome for Global Metabolite ProfilingAnalytical Chemistry, 2011
- Electrospray Ionization Efficiency Scale of Organic CompoundsAnalytical Chemistry, 2010
- Using multivariate statistical methods to model the electrospray ionization response of GXG tripeptides based on multiple physicochemical parametersRapid Communications in Mass Spectrometry, 2009
- Assessment of acetone as an alternative to acetonitrile in peptide analysis by liquid chromatography/mass spectrometryRapid Communications in Mass Spectrometry, 2009
- Virtual Quantification of Metabolites by Capillary Electrophoresis-Electrospray Ionization-Mass Spectrometry: Predicting Ionization Efficiency Without Chemical StandardsAnalytical Chemistry, 2009
- Prediction of high-responding peptides for targeted protein assays by mass spectrometryNature Biotechnology, 2009
- The relative influences of acidity and polarity on responsiveness of small organic molecules to analysis with negative ion electrospray ionization mass spectrometry (ESI-MS)Journal of the American Society for Mass Spectrometry, 2005
- Adduct formation in electrospray ionization mass spectrometryJournal of Chromatography A, 2003
- Adduct formation in electrospray ionization. Part 1: Common acidic pharmaceuticalsJournal of Separation Science, 2002
- Observation of amide anions in solution by electrospray ionization mass spectrometryJournal of the American Society for Mass Spectrometry, 2000